Veritas NetBackup™ Appliance Commands Reference Guide
- Overview
- Appendix A. Main > Appliance commands
- Appendix B. Main > Manage > FibreChannel commands
- Appendix C. Main > Manage > HighAvailability commands
- Appendix D. Main > Manage > Libraries commands
- Appendix E. Main > Manage > Libraries > Advanced > ACS commands
- Appendix F. Main > Manage > License commands
- Appendix G. Main > Manage > MountPoints commands
- Appendix H. Main > Manage > NetBackup CLI commands
- Appendix I. Main > Manage > OpenStorage commands
- Appendix J. Main > Manage > Software commands
- Appendix K. Main > Manage > Storage commands
- Appendix L. Main > Manage > Tapes commands
- Appendix M. Main > Manage > Certificates commands
- Appendix N. Main > Monitor commands
- Appendix O. Main > Network commands
- Appendix P. Main > Network > Security commands (IPsec)
- Appendix Q. Main > Reports commands
- Appendix R. Main > Settings commands
- Appendix S. Main > Settings > Alerts commands
- Appendix T. Main > Settings > Notifications view commands
- Appendix U. Main > Settings > Security commands
- Appendix V. Main > Support commands
Name
Main > Support > ServiceAllowed — Use the ServiceAllowed commands to set specific components of a Primary or an Expansion Storage Shelf to the Service Allowed mode so that service can be performed on those units.
SYNOPSIS
ServiceAllowed Set PrimaryShelf
ServiceAllowed Set ExpansionShelf
DESCRIPTION
The ServiceAllowed command options let you set specific components of a Primary or an Expansion Storage Shelf to the Service Allowed mode so that service can be performed on those units.
Veritas requires that you perform this procedure only with assistance from Veritas Technical Support. Before you attempt to run these commands, refer to the following documents:
NetBackup Appliance Administrator's Guide
NetBackup Appliance Troubleshooting Guide
OPTIONS
The following command options are available for the ServiceAllowed Set PrimaryShelf command:
- ServiceAllowed Set PrimaryShelf Controller location flag
Use this command to set the Service Allowed flag for a Primary Shelf controller.
Where location is A or B, and flag is on or off.
- ServiceAllowed Set PrimaryShelf FanCanister location flag
Use this command to set the Service Allowed flag for a Primary Shelf fan canister.
Where location is Left or Right, and flag is on or off.
- ServiceAllowed Set PrimaryShelf HDD DrawerID SlotNo Flag
Use this command to set the Service Allowed flag for a Primary Shelf hard disk drive.
Where DrawerID is 1-5, SlotNo is 1-12, and flag is on or off.
- ServiceAllowed Set PrimaryShelf PowerCanister location flag
Use this command to set the Service Allowed flag for a Primary Shelf power canister.
Where location is Top or Bottom, and flag is on or off.
The following command options are available for the ServiceAllowed Set ExpansionShelf command:
- ServiceAllowed Set ExpansionShelf ExpansionCanister location flag
Use this command to set the Service Allowed flag for an Expansion Shelf canister.
Where location is Top or Bottom, and flag is on or off.
- ServiceAllowed Set ExpansionShelf FanCanister location flag
Use this command to set the Service Allowed flag for an Expansion Shelf fan canister.
Where location is Left or Right, and flag is on or off.
- ServiceAllowed Set ExpansionShelf HDD ExpansionShelfID DrawerID SlotNo Flag
Use this command to set the Service Allowed flag for an Expansion Shelf hard disk drive.
Where ExpansionShelfID is 0 - 98, DrawerID is 1-5, SlotNo is 1-12, and flag is on or off.
- ServiceAllowed Set ExpansionShelf PowerCanister location flag
Use this command to set the Service Allowed flag for an Expansion Shelf power canister.
Where location is Top or Bottom, and flag is on or off.