InfoScale™ 9.0 Replication Administrator's Guide - AIX
- Section I. Getting started with Volume Replicator
- Introducing Volume Replicator
- Understanding how Volume Replicator works
- How VVR uses kernel buffers for replication
- Replication in a shared disk group environment
- Using SmartTier with VVR
- Understanding the VVR snapshot feature
- About VVR compression
- Planning and configuring replication
- Before you begin configuring
- Choosing the mode of volume replication
- Planning the network
- Sizing the SRL
- Understanding replication settings for a Secondary
- Configuring VVR in a VCS environment
- Using the primary-elect feature to choose the primary site after a site disaster or network disruption
- Requirements for configuring VVR in a VCS environment
- Example setting up VVR in a VCS environment
- Configuring the agents for a bunker replication configuration
- Section II. Setting up and administering VVR
- Setting up replication
- Creating a Replicated Data Set
- Creating a Primary RVG of an RDS
- Adding a Secondary to an RDS
- Changing the replication settings for a Secondary
- Synchronizing the Secondary and starting replication
- Starting replication when the data volumes are zero initialized
- Displaying configuration information
- Displaying RVG and RDS information
- Displaying information about data volumes and volume sets
- Displaying information about Secondaries
- Displaying statistics with the vrstat display commands
- Collecting consolidated statistics of the VVR components
- Displaying network performance data
- Administering Volume Replicator
- Administering data volumes
- Associating a volume to a Replicated Data Set
- Associating a volume set to an RDS
- Associating a Data Change Map to a data volume as a log plex
- Resizing a data volume in a Replicated Data Set
- Administering the SRL
- Incrementally synchronizing the Secondary after SRL overflow
- Administering replication
- Administering the Replicated Data Set
- Administering Storage Checkpoints
- Creating RVG snapshots
- Using the instant snapshot feature
- About instant full snapshots
- Preparing the volumes prior to using the instant snapshot feature
- Creating instant full snapshots
- About instant space-optimized snapshots
- Creating instant space-optimized snapshots
- About instant plex-breakoff snapshots
- Administering snapshots
- Using the traditional snapshot feature
- Using Veritas Volume Manager FastResync
- Verifying the DR readiness of a VVR setup
- Backing up the Secondary
- Administering data volumes
- Using VVR for off-host processing
- Transferring the Primary role
- Migrating the Primary
- About taking over from an original Primary
- Failing back to the original Primary
- Choosing the Primary site after a site disaster or network disruption
- Troubleshooting the primary-elect feature
- Replication using a bunker site
- Introduction to replication using a bunker site
- Setting up replication using a bunker site
- Using a bunker for disaster recovery
- Replication using a bunker site in a VCS environment
- Configuring and administering VVR using System Management Interface Tool
- Accessing Volume Replicator interface in SMIT
- Setting up a simple Volume Replicator configuration using SMIT
- Displaying configuration information using SMIT
- Administering Volume Replicator using SMIT
- Taking instant snapshot of data volumes of an RVG using SMIT
- Associating a volume to a Replicated Data Set using SMIT
- Transferring the Primary role using SMIT
- Troubleshooting VVR
- Recovery from configuration errors
- Errors during an RLINK attach
- Errors during modification of an RVG
- Recovery on the Primary or Secondary
- Recovering from Primary data volume error
- Primary SRL volume error cleanup and restart
- Primary SRL header error cleanup and recovery
- Secondary data volume error cleanup and recovery
- Tuning replication performance
- SRL layout
- Tuning Volume Replicator
- VVR buffer space
- Tuning VVR compression
- VVR buffer space
- Setting up replication
- Section III. Analyzing your environment with Volume Replicator Advisor
- Introducing Volume Replicator Advisor (VRAdvisor)
- Collecting the sample of data
- About collecting the sample of data
- Collecting the sample of data on UNIX
- Collecting the sample of data on Windows
- Analyzing the sample of data
- About analyzing the sample of data
- Analyzing the collected data
- Understanding the results of the analysis
- Viewing the analysis results
- Recalculating the analysis results
- Installing Volume Replicator Advisor (VRAdvisor)
- Section IV. VVR reference
- Appendix A. VVR command reference
- Appendix B. Using the In-band Control Messaging utility vxibc and the IBC programming API
- Using the IBC messaging command-line utility
- Examples - Off-host processing
- In-band Control Messaging API
- Appendix C. Volume Replicator object states
- Appendix D. Alternate methods for synchronizing the Secondary
- Using the full synchronization feature
- Using block-level backup and Storage Checkpoint
- Using difference-based synchronization
- Examples for setting up a simple Volume Replicator configuration
- Appendix E. Migrating VVR from IPv4 to IPv6
- Migrating VVR to support IPv6 or dual stack
- About migrating to IPv6 when VCS global clustering and VVR agents are not configured
- About migrating to IPv6 when VCS global clustering and VVR agents are configured
- About migrating to IPv6 when VCS global clustering and VVR agents are configured in the presence of a bunker
- Migrating to IPv6 when VCS global clustering and VVR agents are configured in the presence of a bunker
- Appendix F. Sample main.cf files
Migrating the VCS global clustering service group to IPv6 when VCS global clustering and VVR agents are configured
An online migration of the VCS global clustering service group is not supported. Put the service group offline and then modify the required parameters.
To migrate the VCS global clustering service to IPv6, do the following:
Take the ClusterService Group offline on the Primary and Secondary sites.
Edit the VCS configuration for IPv6 addresses.
Bring the ClusterService Group online on the Primary and Secondary sites.
To take the ClusterService Group offline on the Primary and Secondary sites
- On the Primary and Secondary sites, enter the following command:
# hagrp -offline -force ClusterService -sys node_name
For example, on the Primary site, enter the following:
# hagrp -offline -force ClusterService -sys swax25
On the Secondary site, enter the following:
# hagrp -offline -force ClusterService -sys swax27
Note:
Putting the service group offline does not impact the replication between the sites.
To edit the VCS configuration for IPv6 addresses
- On the Primary site, make the VCS configuration writeable. Enter the following:
# haconf -makerw
- Modify the VCS global clustering related attribute values to support the IPv6 environment. Enter the following:
# haclus -modify ClusterAddress \ fd4b:454e:205a:111:213:72ff:fe5b:2f67 -clus sfcfs_gco1 # haclus -modify ClusterAddress \ fd4b:454e:205a:111:211:43ff:fede:1e11 -clus sfcfs_gco2 # hahb -modify Icmp Arguments \ fd4b:454e:205a:111:211:43ff:fede:1e11 -clus sfcfs_gco2 # hares -modify gcoip Address \ fd4b:454e:205a:111:213:72ff:fe5b:2f67 # hares -modify gcoip Enabled 1 # hares -modify gcoip PrefixLen 64 # hares -modify gcoip NetMask "" # hares -modify gcoip Device en1 # hares -modify gconic Device en1 # hares -modify gconic Enabled 1
- Save your configuration changes. Enter the following:
# haconf -dump -makero
- Modify the VCS global clustering related attributes on the Secondary site using steps 1 through 3.
To bring the ClusterService Group online on the Primary and Secondary sites
- On the Primary and Secondary sites, enter the following:
# hagrp -online ClusterService -sys node_name
For example, on the Primary site, enter the following:
# hagrp -online -force ClusterService -sys swax25
On the Secondary site, enter the following:
# hagrp -online -force ClusterService -sys swax27
The global clustering ClusterService Group in the VCS main.cf
configuration file now looks similar to the following:
cluster sfcfs_gco1 ( ClusterAddress = "fd4b:454e:205a:111:213:72ff:fe5b:2f67" SecureClus = 1 HacliUserLevel = COMMANDROOT ) remotecluster sfcfs_gco2 ( ClusterAddress = "fd4b:454e:205a:111:211:43ff:fede:1e11" ) heartbeat Icmp ( ClusterList = { sfcfs_gco2 } Arguments @sfcfs_gco2 = { "fd4b:454e:205a:111:211:43ff:fede:1e11" } ) system swax20 ( ) system swax21 ( ) group ClusterService ( SystemList = { swax20 = 0, swax21 = 1 } AutoStartList = { swax20, swax21 } OnlineRetryLimit = 3 OnlineRetryInterval = 120 ) Application wac ( StartProgram = "/opt/VRTSvcs/bin/wacstart" StopProgram = "/opt/VRTSvcs/bin/wacstop" MonitorProcesses = { "/opt/VRTSvcs/bin/wac" } RestartLimit = 3 ) IP gcoip ( Device = en1 Address = "fd4b:454e:205a:111:213:72ff:fe5b:2f67" PrefixLen = 64 ) NIC gconic ( Device = en1 ) gcoip requires gconic wac requires gcoip