- Overview
- Preparing for hardware installation
- Installing an appliance and 3U16 storage shelves into racks
- Cables
- Verifying hardware operation and configuring IPMI
- Appendix A. Adding 3U16 storage shelves to an operational NetBackup 5230 Appliance
- Appendix B. Adding 2U12 storage shelves to an operational NetBackup 5230 Appliance
- Appendix C. Adding new disk space to the appliance configuration
Installing the additional Maintenance Free Backup Unit (MFBU)
To install the MFBU
- Put on an ESD-compliant wrist strap or take other ESD-protective measures.
- Remove the following components from the Expansion Storage Kit.
- Insert the MFBU into the case. Do not damage or twist the wires that are attached to the MFBU.
- View the appliance from the front left side.
- Locate the fan on the left side of the chassis.
- Remove the air baffle that is located near the fans as needed.
- Remove the fan on the far left.
- Attach the MFBU cable to the MFBU. The other end of the cable attaches to the external RAID card when it is installed.
- Position the MFBU against the chassis side wall (1) and through the opening in the fan bulk-head (2).
- Align the tabs on the MFBU case with the mounting holes in the chassis.
- Slide the MFBU case towards the front of the appliance until the tabs engage with the mounting holes.
- Route the MFBU cable along the side of the chassis towards the rear of the appliance.
- Proceed to the next section to install the external RAID PCIe card and to connect it to the MFBU cable.