Veritas Enterprise Vault™ Registry Values
- About this guide
- Admin Service
- Administration Console
- Agents
- Backtrace
- Clustering
- Code Page Detection
- Directory Service
- Enterprise Vault
- EVcloudExporter
- Event filtering
- External filtering
- File System Archiving
- Indexing
- Installation
- Outlook Add-In
- Location of Outlook Add-In registry values
- Selective Journaling
- Storage Service
PassThruRecallLimitMaxRecalls
Location |
On a 32-bit installation of Windows: HKEY_LOCAL_MACHINE \SOFTWARE \KVS \Enterprise Vault \FSA \PlaceholderService \PassThrough On a 64-bit installation of Windows: HKEY_LOCAL_MACHINE \SOFTWARE \Wow6432Node \KVS \Enterprise Vault \FSA \PlaceholderService \PassThrough |
Content | DWORD Initial value 20 |
Description | For Windows file servers you can specify a maximum rate of pass-through recall on each computer that runs a Placeholder service. This value controls the maximum rate at which an individual user can retrieve files. The limit also prevents any applications that do not honor the file system offline attribute from retrieving all the files that have been archived from a volume. If the maximum rate is exceeded, the application receives an Access Denied status. How the status is displayed to the user depends on the individual application. PassThruRecallLimitMaxRecalls specifies the maximum number of items that you can retrieve for pass-through recall in PassThruRecallLimitTimeInterval seconds. See PassThruRecallLimitTimeInterval. The default maximum rate is 20 recalls in 10 seconds. When the maximum retrieval rate is reached, there is an additional wait of PassThruRecallLimitTimeInterval seconds before Enterprise Vault resets the count. The limit only takes effect if you enable it by using EnableRecallLimitForPassThrough. |
See also |