- About planning to configure I/O fencing
- Setting up the CP server
- Configuring the CP server manually
- Configuring CP server using response files
- Configuring SFHA
- Configuring Storage Foundation High Availability using the installer
- Configuring a secure cluster node by node
- Completing the SFHA configuration
- Verifying and updating licenses on the system
- Configuring Storage Foundation High Availability using the installer
- Configuring SFHA clusters for data integrity
- Setting up disk-based I/O fencing using installer
- Setting up server-based I/O fencing using installer
- Manually configuring SFHA clusters for data integrity
- Setting up disk-based I/O fencing manually
- Setting up server-based I/O fencing manually
- Configuring server-based fencing on the SFHA cluster manually
- Setting up non-SCSI-3 fencing in virtual environments manually
- Setting up majority-based I/O fencing manually
- Performing an automated SFHA configuration using response files
- Performing an automated I/O fencing configuration using response files
- Section III. Upgrade of SFHA
- Planning to upgrade SFHA
- Preparing to upgrade SFHA
- Upgrading Storage Foundation and High Availability
- Performing a rolling upgrade of SFHA
- Performing a phased upgrade of SFHA
- About phased upgrade
- Performing a phased upgrade using the product installer
- Performing an automated SFHA upgrade using response files
- Upgrading SFHA using YUM
- Performing post-upgrade tasks
- Post-upgrade tasks when VCS agents for VVR are configured
- About enabling LDAP authentication for clusters that run in secure mode
- Planning to upgrade SFHA
- Section IV. Post-installation tasks
- Section V. Adding and removing nodes
- Adding a node to SFHA clusters
- Adding the node to a cluster manually
- Adding a node using response files
- Configuring server-based fencing on the new node
- Removing a node from SFHA clusters
- Removing a node from a SFHA cluster
- Removing a node from a SFHA cluster
- Adding a node to SFHA clusters
- Section VI. Configuration and upgrade reference
- Appendix A. Installation scripts
- Appendix B. SFHA services and ports
- Appendix C. Configuration files
- Appendix D. Configuring the secure shell or the remote shell for communications
- Appendix E. Sample SFHA cluster setup diagrams for CP server-based I/O fencing
- Appendix F. Configuring LLT over UDP
- Using the UDP layer for LLT
- Manually configuring LLT over UDP using IPv4
- Using the UDP layer of IPv6 for LLT
- Manually configuring LLT over UDP using IPv6
- About configuring LLT over UDP multiport
- Appendix G. Using LLT over RDMA
- Configuring LLT over RDMA
- Configuring RDMA over an Ethernet network
- Configuring RDMA over an InfiniBand network
- Tuning system performance
- Manually configuring LLT over RDMA
- Troubleshooting LLT over RDMA
Coordinator disk requirements for I/O fencing
Make sure that the I/O fencing coordinator disks meet the following requirements:
For disk-based I/O fencing, you must have at least three coordinator disks or there must be odd number of coordinator disks.
The coordinator disks must be DMP devices.
Each of the coordinator disks must use a physically separate disk or LUN.
Arctera recommends using the smallest possible LUNs for coordinator disks.
Each of the coordinator disks should exist on a different disk array, if possible.
The coordinator disks must support SCSI-3 persistent reservations.
Coordinator devices can be attached over iSCSI protocol but they must be DMP devices and must support SCSI-3 persistent reservations.
Arctera recommends using hardware-based mirroring for coordinator disks.
Coordinator disks must not be used to store data or must not be included in disk groups that store user data.
Coordinator disks cannot be the special devices that array vendors use. For example, you cannot use EMC gatekeeper devices as coordinator disks.
The coordinator disk size must be at least 128 MB.