InfoScale™ 9.0 Storage Foundation and High Availability Configuration and Upgrade Guide - Linux
- Section I. Introduction to SFHA
- Section II. Configuration of SFHA
- Preparing to configure
- Preparing to configure SFHA clusters for data integrity
- About planning to configure I/O fencing
- Setting up the CP server
- Configuring the CP server manually
- Configuring CP server using response files
- Configuring SFHA
- Configuring Storage Foundation High Availability using the installer
- Configuring a secure cluster node by node
- Completing the SFHA configuration
- Verifying and updating licenses on the system
- Configuring Storage Foundation High Availability using the installer
- Configuring SFHA clusters for data integrity
- Setting up disk-based I/O fencing using installer
- Setting up server-based I/O fencing using installer
- Manually configuring SFHA clusters for data integrity
- Setting up disk-based I/O fencing manually
- Setting up server-based I/O fencing manually
- Configuring server-based fencing on the SFHA cluster manually
- Setting up non-SCSI-3 fencing in virtual environments manually
- Setting up majority-based I/O fencing manually
- Performing an automated SFHA configuration using response files
- Performing an automated I/O fencing configuration using response files
- Section III. Upgrade of SFHA
- Planning to upgrade SFHA
- Preparing to upgrade SFHA
- Upgrading Storage Foundation and High Availability
- Performing a rolling upgrade of SFHA
- Performing a phased upgrade of SFHA
- About phased upgrade
- Performing a phased upgrade using the product installer
- Performing an automated SFHA upgrade using response files
- Upgrading SFHA using YUM
- Performing post-upgrade tasks
- Post-upgrade tasks when VCS agents for VVR are configured
- About enabling LDAP authentication for clusters that run in secure mode
- Planning to upgrade SFHA
- Section IV. Post-installation tasks
- Section V. Adding and removing nodes
- Adding a node to SFHA clusters
- Adding the node to a cluster manually
- Adding a node using response files
- Configuring server-based fencing on the new node
- Removing a node from SFHA clusters
- Removing a node from a SFHA cluster
- Removing a node from a SFHA cluster
- Adding a node to SFHA clusters
- Section VI. Configuration and upgrade reference
- Appendix A. Installation scripts
- Appendix B. SFHA services and ports
- Appendix C. Configuration files
- Appendix D. Configuring the secure shell or the remote shell for communications
- Appendix E. Sample SFHA cluster setup diagrams for CP server-based I/O fencing
- Appendix F. Configuring LLT over UDP
- Using the UDP layer for LLT
- Manually configuring LLT over UDP using IPv4
- Using the UDP layer of IPv6 for LLT
- Manually configuring LLT over UDP using IPv6
- About configuring LLT over UDP multiport
- Appendix G. Using LLT over RDMA
- Configuring LLT over RDMA
- Configuring RDMA over an Ethernet network
- Configuring RDMA over an InfiniBand network
- Tuning system performance
- Manually configuring LLT over RDMA
- Troubleshooting LLT over RDMA
Upgrading disk layout versions
In this release, you can create and mount only file systems with disk layout version 14, 15, 16, 17, and 18. You can local mount disk layout version 7, 8, 9, 10, 11, 12, and 13 to upgrade to a later disk layout version.
Note:
If you plan to use 64-bit quotas, you must upgrade to the disk layout version 10 or later.
Disk layout version 7, 8, 9, 10, 11, 12, and 13 are deprecated and you cannot cluster mount an existing file system that has any of these versions.
To upgrade a cluster file system from any of these deprecated versions, you must local mount the file system and then upgrade it using the vxupgrade utility or the vxfsconvert utility.
The vxupgrade utility enables you to upgrade the disk layout while the file system is online. However, the vxfsconvert utility enables you to upgrade the disk layout while the file system is offline.
If you use the vxupgrade utility, you must incrementally upgrade the disk layout versions. However, you can directly upgrade to a desired version, using the vxfsconvert utility.
For example, to upgrade from disk layout version 7 to a disk layout version 10, using the vxupgrade utility:
# vxupgrade -n 8 /mnt # vxupgrade -n 9 /mnt # vxupgrade -n 10 /mnt
See the vxupgrade
(1M) manual page.
See the vxfsconvert
(1M) manual page.
Note:
Arctera recommends that before you begin to upgrade the product version, you must upgrade the existing file system to the highest supported disk layout version. Once a disk layout version has been upgraded, it is not possible to downgrade to the previous version.
Use the following command to check your disk layout version:
# fstyp -v /dev/vx/dsk/dg1/vol1 | grep -i version
For more information about disk layout versions, see the Storage Foundation Administrator's Guide.