Veritas Flex Appliance SNMP Traps Reference Guide
- Overview
- SNMP traps
vrtsapplianceLocalServicesTrap
OID: 1.3.6.1.4.1.48328.3.9.2.13
The vrtsapplianceLocalServicesTrap monitors the infrastructure services on a specific appliance node. If you receive an alert, it means that one of the services has experienced an error.
Check the value of the <node prefix>_flexclovalservice_<service>_status field to see which service is not in an optimal status. Then search the Veritas Support site for the associated UMI code, as shown in the following table.
Table: Associated UMI codes for the vrtsapplianceLocalServicesTrap
Trap | Value | UMI code |
---|---|---|
containers-filevol-plugin | The application configuration volume plug-in service is not in an optimal state. | V-475-130-30010 |
etcd | The etcd service is not in an optimal state. | V-475-130-30005 |
metrics-node | The metrics-node service is not in an optimal state. | V-475-130-30007 |
metrics-server | The metrics-server service is not in an optimal state. | V-475-130-30006 |
metrics-storage | The metrics-storage service is not in an optimal state. | V-475-130-30009 |
remotemgmt | The remotemgmt service is not in an optimal state. | V-475-130-30004 |
settings | The settings service is not in an optimal state. | V-475-130-30003 |