Veritas Flex Appliance SNMP Traps Reference Guide

Last Published:
Product(s): Appliances (Version Not Specified)
Platform: Veritas 5150,Veritas 5250,Veritas 5260,Veritas 5340,Veritas 5350,Veritas 5360

vrtsapplianceClusterServicesTrap

OID: 1.3.6.1.4.1.48328.3.9.2.14

Description

The vrtsapplianceClusterServicesTrap monitors the services that run on the nodes of a multi-node appliance. If you receive an alert, it means that one of the services has experienced an error.

Resolution

Check the value of the <node prefix>_flexclusterservice_<service>_status field to see which service is not in an optimal status. Then search the Veritas Support site for the associated UMI code, as shown in the following table.

Table: Associated UMI codes for the vrtsapplianceClusterServicesTrap

Service

Value

UMI code

infra_svc

OFFLINE

V-475-130-30011

infra_svc

The infrastructure service failed over to node <node hostname>.

V-475-130-30012

infra_svc

Dependent services require manual intervention.

Node <node hostname>: <list of services>.

Note that the same alert is sent from all nodes in the appliance.

V-475-130-30016

<instance ID>

Application instance <instance ID> offline.

V-475-130-30013

<instance ID>

Application instance <instance ID> failed over to node <node hostname>.

V-475-130-30014

<instance ID>

Application instance <instance ID> has reported a NetBackup service error.

V-475-130-30015