Veritas Flex Appliance SNMP Traps Reference Guide
- Overview
- SNMP traps
vrtsfanTrap
OID: 1.3.6.1.4.1.48328.3.9.1.3
The vrtsfanTrap monitors the status of the appliance fans. If you receive an alert, it means that one or more of the system fans has experienced an error. Either a fan has stopped working, or the fan rpm has crossed the threshold value that is required for proper system functioning.
Check the SNMP trap or the email alert that you received for additional information to help you determine the exact issue that occurred. You can also check the show hardware-health commands. See the Flex Appliance Getting Started and Administration Guide for details.
Based on the information, take one of the following actions:
Table: Next steps for the vrtsfanTrap
What happened | What to do now |
---|---|
If the fan State is Warning, the fan is running slower than the low threshold of 1715 rpm. | Check the system temperature. Check the power supply. If both are normal, contact Veritas Support to replace the fan. |
If the fan State is Failed, the fan is missing or has failed. | Contact Veritas Support to replace the fan. |