Storage Foundation for Sybase ASE CE 7.4 Administrator's Guide - Linux
- Overview of Storage Foundation for Sybase ASE CE
- About Storage Foundation for Sybase ASE CE
- About SF Sybase CE components
- About optional features in SF Sybase CE
- Administering SF Sybase CE and its components
- Administering SF Sybase CE
- Starting or stopping SF Sybase CE on each node
- Administering VCS
- Administering I/O fencing
- About the vxfentsthdw utility
- Testing the coordinator disk group using the -c option of vxfentsthdw
- About the vxfenadm utility
- About the vxfenclearpre utility
- About the vxfenswap utility
- Administering CVM
- Changing the CVM master manually
- Administering CFS
- Administering the Sybase agent
- Administering SF Sybase CE
- Troubleshooting SF Sybase CE
- About troubleshooting SF Sybase CE
- Troubleshooting I/O fencing
- Fencing startup reports preexisting split-brain
- Troubleshooting Cluster Volume Manager in SF Sybase CE clusters
- Troubleshooting interconnects
- Troubleshooting Sybase ASE CE
- Prevention and recovery strategies
- Prevention and recovery strategies
- Managing SCSI-3 PR keys in SF Sybase CE cluster
- Prevention and recovery strategies
- Tunable parameters
- Appendix A. Error messages
Fencing startup reports preexisting split-brain
The vxfen driver functions to prevent an ejected node from rejoining the cluster after the failure of the private network links and before the private network links are repaired.
For example, suppose the cluster of system 1 and system 2 is functioning normally when the private network links are broken. Also suppose system 1 is the ejected system. When system 1 restarts before the private network links are restored, its membership configuration does not show system 2; however, when it attempts to register with the coordinator disks, it discovers system 2 is registered with them. Given this conflicting information about system 2, system 1 does not join the cluster and returns an error from vxfenconfig that resembles:
vxfenconfig: ERROR: There exists the potential for a preexisting split-brain. The coordinator disks list no nodes which are in the current membership. However, they also list nodes which are not in the current membership. I/O Fencing Disabled!
Also, the following information is displayed on the console:
<date> <system name> vxfen: WARNING: Potentially a preexisting <date> <system name> split-brain. <date> <system name> Dropping out of cluster. <date> <system name> Refer to user documentation for steps <date> <system name> required to clear preexisting split-brain. <date> <system name> <date> <system name> I/O Fencing DISABLED! <date> <system name> <date> <system name> gab: GAB:20032: Port b closed
However, the same error can occur when the private network links are working and both systems go down, system 1 restarts, and system 2 fails to come back up. From the view of the cluster from system 1, system 2 may still have the registrations on the coordination points.