Storage Foundation for Sybase ASE CE 7.4 Administrator's Guide - Linux
- Overview of Storage Foundation for Sybase ASE CE
- About Storage Foundation for Sybase ASE CE
- About SF Sybase CE components
- About optional features in SF Sybase CE
- Administering SF Sybase CE and its components
- Administering SF Sybase CE
- Starting or stopping SF Sybase CE on each node
- Administering VCS
- Administering I/O fencing
- About the vxfentsthdw utility
- Testing the coordinator disk group using the -c option of vxfentsthdw
- About the vxfenadm utility
- About the vxfenclearpre utility
- About the vxfenswap utility
- Administering CVM
- Changing the CVM master manually
- Administering CFS
- Administering the Sybase agent
- Administering SF Sybase CE
- Troubleshooting SF Sybase CE
- About troubleshooting SF Sybase CE
- Troubleshooting I/O fencing
- Fencing startup reports preexisting split-brain
- Troubleshooting Cluster Volume Manager in SF Sybase CE clusters
- Troubleshooting interconnects
- Troubleshooting Sybase ASE CE
- Prevention and recovery strategies
- Prevention and recovery strategies
- Managing SCSI-3 PR keys in SF Sybase CE cluster
- Prevention and recovery strategies
- Tunable parameters
- Appendix A. Error messages
GAB port membership
To check GAB port membership
Enter the following command:
# /sbin/gabconfig -a
Port b must exist on the local system.
The output resembles this information:
GAB Port Memberships =============================================================== Port a gen 4a1c0001 membership 01 Port b gen ada40d01 membership 01 Port f gen f1990002 membership 01 Port h gen d8850002 membership 01 Port m gen d8860002 membership 01 Port u gen de4f0203 membership 01 Port v gen 1fc60002 membership 01 Port w gen 15ba0002 membership 01 Port y gen 73f449 membership 01
Table: GAB port function defines each GAB port's function.
For illustration of different GAB ports,
Table: GAB port function
Port | Function |
---|---|
a | This port is used for GAB internally. |
b | This port is used for I/O fencing communications. |
f | CFS uses this port for GLM lock and metadata communication. |
h | VCS uses this port. VCS communicates the status of resources running on each system to all systems in the cluster. |
m | CVM uses this port for SmartIO VxVM cache coherency. |
u | CVM uses this port to ship commands from slave node to master node. |
v | CVM uses this port for kernel-to-kernel communication. |
w | vxconfigd configuration daemon (module for CVM) uses this port for messaging. |
y | CVM uses this port for I/O shipping. |