Storage Foundation for Sybase ASE CE 7.4 Administrator's Guide - Linux
- Overview of Storage Foundation for Sybase ASE CE
- About Storage Foundation for Sybase ASE CE
- About SF Sybase CE components
- About optional features in SF Sybase CE
- Administering SF Sybase CE and its components
- Administering SF Sybase CE
- Starting or stopping SF Sybase CE on each node
- Administering VCS
- Administering I/O fencing
- About the vxfentsthdw utility
- Testing the coordinator disk group using the -c option of vxfentsthdw
- About the vxfenadm utility
- About the vxfenclearpre utility
- About the vxfenswap utility
- Administering CVM
- Changing the CVM master manually
- Administering CFS
- Administering the Sybase agent
- Administering SF Sybase CE
- Troubleshooting SF Sybase CE
- About troubleshooting SF Sybase CE
- Troubleshooting I/O fencing
- Fencing startup reports preexisting split-brain
- Troubleshooting Cluster Volume Manager in SF Sybase CE clusters
- Troubleshooting interconnects
- Troubleshooting Sybase ASE CE
- Prevention and recovery strategies
- Prevention and recovery strategies
- Managing SCSI-3 PR keys in SF Sybase CE cluster
- Prevention and recovery strategies
- Tunable parameters
- Appendix A. Error messages
About the vxfenswap utility
The vxfenswap utility allows you to add, remove, and replace coordinator points in a cluster that is online. The utility verifies that the serial number of the new disks are identical on all the nodes and the new disks can support I/O fencing.
The utility uses SSH, RSH, or hacli for communication between nodes in the cluster. Before you execute the utility, ensure that communication between nodes is set up in one these communication protocols.
Refer to the vxfenswap
(1M) manual page.
See the Storage Foundation for Sybase ASE CE Configuration Guide for details on the I/O fencing requirements.
You can replace the coordinator disks without stopping I/O fencing in the following cases:
The disk becomes defective or inoperable and you want to switch to a new disk group.
See Replacing I/O fencing coordinator disks when the cluster is online.
See Replacing the coordinator disk group in a cluster that is online.
If you want to replace the coordinator disks when the cluster is offline, you cannot use the vxfenswap utility. You must manually perform the steps that the utility does to replace the coordinator disks.
The keys that are registered on the coordinator disks are lost.
In such a case, the cluster might panic when a network partition occurs. You can replace the coordinator disks with the same disks using the vxfenswap command. During the disk replacement, the missing keys register again without any risk of data corruption.
If the vxfenswap operation is unsuccessful, then you can use the -a cancel of the vxfenswap command to manually roll back the changes that the vxfenswap utility does.
For disk-based fencing, use the vxfenswap -g diskgroup -a cancel command to cancel the vxfenswap operation.
You must run this command if a node fails during the process of disk replacement, or if you aborted the disk replacement.