Veritas InfoScale™ Operations Manager 7.3.1 Add-ons User's Guide
- Section I. VCS Utilities Add-on 7.3.1
- Section II. Distribution Manager Add-on 7.3.1
- Section III. Fabric Insight Add-on 7.3.1
- Section IV. Patch Installer Add-on 7.3.1
- Introduction to Patch Installer Add-on
- Using Patch Installer Add-on
- Section V. Storage Insight Add-on 7.3.1
- Performing the deep discovery of enclosures
- About Storage Insight Add-on
- Adding HITACHI storage enclosures for deep discovery
- Editing the deep discovery configuration for an enclosure
- Monitoring the usage of thin pools
- Monitoring storage array metering data
- Managing LUN classifications
- Appendix A. Enclosure configuration prerequisites
- HITACHI enclosure configuration prerequisites
- EMC Symmetrix storage array configuration prerequisites
- Device setup requirements for EMC Symmetrix arrays
- IBM XIV enclosure configuration prerequisites
- NetApp storage enclosure configuration prerequisites
- EMC CLARiiON storage enclosures configuration prerequisites
- Hewlett-Packard Enterprise Virtual Array (HP EVA) configuration prerequisites
- IBM System Storage DS enclosure configuration prerequisites
- IBM SVC enclosure configuration prerequisites
- EMC Celerra enclosure configuration prerequisites
- EMC VNX storage enclosure configuration prerequisites
- EMC VPLEX storage enclosure configuration prerequisites
- Appendix B. Commands used by Management Server for deep discovery of enclosures
- Performing the deep discovery of enclosures
- Section VI. Storage Insight SDK Add-on 7.3.1
- Overview of Storage Insight SDK Add-on 7.3.1
- Managing Veritas InfoScale Operations Manager Storage Insight plug-ins
- About creating Storage Insight plug-in
- About discovery script
- About the enclosure discovery command output
- Creating a Storage Insight plug-in
- Editing a Storage Insight plug-in
- Testing a Storage Insight plug-in
- About creating Storage Insight plug-in
- Section VII. Storage Provisioning and Enclosure Migration Add-on 7.3.1
- Provisioning storage
- Creating a storage template using VxFS file systems
- Migrating volumes
- Provisioning storage
- Section VIII. Veritas HA Plug-in for VMware vSphere Web Client
- Introduction to Veritas HA Plug-in for vSphere Web Client
- Installation and uninstallation of Veritas HA Plug-in for vSphere Web Client
- Configurations for Veritas HA Plug-in for vSphere Web Client
- Section IX. Application Migration Add-on
- Introduction to Application Migration Add-on
- Creating and managing an application migration plan
- Understanding application migration operations
EMC VNX (File) storage enclosure commands
The following XML APIs are used to form the XML queries that are required to get the information about EMC VNX (File) storage enclosure:
<ControlStationQueryParams/>: Command to get the information about Celerra Control station.
<CelerraSystemQueryParams/>: Command to get the detailed information about Celerra systems.
<VolumeQueryParams/>: Command to get the information about Celerra volumes.
<StoragePoolQueryParams/>: Command to get the information about Celerra storage pools.
<FileSystemQueryParams/>: Command to get the information about NAS file systems.
<CifsShareQueryParams/>: Command to get the information about CIFS shares.
<CifsServerQueryParams/>: Command to get the information about CIFS servers.
<NfsExportQueryParams/>: Command to get the information about NFS export.
<UserQuotaQueryParams/>: Command to get the information about user quota on the file systems.
<MoverQueryParams>: Command to get the information about data movers.
<VdmQueryParams/>: Command to get the information about virtual data movers.
<IscsiTargetQueryParams>: Command to get the information about iSCSI targets.
<IscsiLunQueryParams/>: Command to get the information about iSCSI LUNs.
<IscsiMaskQueryParams/>: Command to get the information about iSCSI LUN masking.
<StorageSystemQueryParams storage=\"<storage ID>\"/>: Command to get the detailed information about Celerra enclosure.
<ClariionDeviceQueryParams/>: Command to get the information about back-end CLARiiON device.
<SymmDeviceQueryParams/>: Command to get the information about back-end Symmetrix device.
More Information