Veritas InfoScale™ Operations Manager 7.3.1 Add-ons User's Guide
- Section I. VCS Utilities Add-on 7.3.1
- Section II. Distribution Manager Add-on 7.3.1
- Section III. Fabric Insight Add-on 7.3.1
- Section IV. Patch Installer Add-on 7.3.1
- Introduction to Patch Installer Add-on
- Using Patch Installer Add-on
- Section V. Storage Insight Add-on 7.3.1
- Performing the deep discovery of enclosures
- About Storage Insight Add-on
- Adding HITACHI storage enclosures for deep discovery
- Editing the deep discovery configuration for an enclosure
- Monitoring the usage of thin pools
- Monitoring storage array metering data
- Managing LUN classifications
- Appendix A. Enclosure configuration prerequisites
- HITACHI enclosure configuration prerequisites
- EMC Symmetrix storage array configuration prerequisites
- Device setup requirements for EMC Symmetrix arrays
- IBM XIV enclosure configuration prerequisites
- NetApp storage enclosure configuration prerequisites
- EMC CLARiiON storage enclosures configuration prerequisites
- Hewlett-Packard Enterprise Virtual Array (HP EVA) configuration prerequisites
- IBM System Storage DS enclosure configuration prerequisites
- IBM SVC enclosure configuration prerequisites
- EMC Celerra enclosure configuration prerequisites
- EMC VNX storage enclosure configuration prerequisites
- EMC VPLEX storage enclosure configuration prerequisites
- Appendix B. Commands used by Management Server for deep discovery of enclosures
- Performing the deep discovery of enclosures
- Section VI. Storage Insight SDK Add-on 7.3.1
- Overview of Storage Insight SDK Add-on 7.3.1
- Managing Veritas InfoScale Operations Manager Storage Insight plug-ins
- About creating Storage Insight plug-in
- About discovery script
- About the enclosure discovery command output
- Creating a Storage Insight plug-in
- Editing a Storage Insight plug-in
- Testing a Storage Insight plug-in
- About creating Storage Insight plug-in
- Section VII. Storage Provisioning and Enclosure Migration Add-on 7.3.1
- Provisioning storage
- Creating a storage template using VxFS file systems
- Migrating volumes
- Provisioning storage
- Section VIII. Veritas HA Plug-in for VMware vSphere Web Client
- Introduction to Veritas HA Plug-in for vSphere Web Client
- Installation and uninstallation of Veritas HA Plug-in for vSphere Web Client
- Configurations for Veritas HA Plug-in for vSphere Web Client
- Section IX. Application Migration Add-on
- Introduction to Application Migration Add-on
- Creating and managing an application migration plan
- Understanding application migration operations
Adding HITACHI storage enclosures for deep discovery
The Storage Insight Add-on provides you detailed information on the storage enclosures in your data center. The Storage Insight Add-on makes use of HiCommand server that is connected to a host, which you can designate as the discovery host to get the information from HITACHI enclosures. This host need not be a part of the Management Server. The HITACHI agentlet that resides on the Management Server pushes the application programming interface (API) commands to the discovery host to get the information from the HiCommand server using XML. The discovery host runs the commands to collect the information on the enclosures. This information, which is brought to the Management Server, is parsed and put in the Veritas InfoScale Operations Manager database.
Before you add an enclosure for deep discovery, ensure that you meet the configuration prerequisites.
To perform this task, your user group must be assigned the Admin role on the Management Server perspective.
To add HITACHI storage enclosures for deep discovery
- In the Home page on the Management Server console, click Settings.
- Do one of the following:
Click Device and click Add Enclosure.
Click Add Enclosure.
- In the Add Enclosure wizard panel, select the vendor and the enclosure model. Click Next.
See Add Enclosure panel options for vendor and product selection.
- In the Add Enclosure wizard panel to specify the details of the devices, enter the required information. Click Next.
- In the Add Enclosure wizard panel that lists the HITACHI enclosures that are connected to the HiCommand server, enter the required information to update discovery information. Click Finish.
See Add Enclosure panel options to update the enclosures discovery information.