Veritas InfoScale™ Operations Manager 7.3.1 Add-ons User's Guide
- Section I. VCS Utilities Add-on 7.3.1
- Section II. Distribution Manager Add-on 7.3.1
- Section III. Fabric Insight Add-on 7.3.1
- Section IV. Patch Installer Add-on 7.3.1
- Introduction to Patch Installer Add-on
- Using Patch Installer Add-on
- Section V. Storage Insight Add-on 7.3.1
- Performing the deep discovery of enclosures
- About Storage Insight Add-on
- Adding HITACHI storage enclosures for deep discovery
- Editing the deep discovery configuration for an enclosure
- Monitoring the usage of thin pools
- Monitoring storage array metering data
- Managing LUN classifications
- Appendix A. Enclosure configuration prerequisites
- HITACHI enclosure configuration prerequisites
- EMC Symmetrix storage array configuration prerequisites
- Device setup requirements for EMC Symmetrix arrays
- IBM XIV enclosure configuration prerequisites
- NetApp storage enclosure configuration prerequisites
- EMC CLARiiON storage enclosures configuration prerequisites
- Hewlett-Packard Enterprise Virtual Array (HP EVA) configuration prerequisites
- IBM System Storage DS enclosure configuration prerequisites
- IBM SVC enclosure configuration prerequisites
- EMC Celerra enclosure configuration prerequisites
- EMC VNX storage enclosure configuration prerequisites
- EMC VPLEX storage enclosure configuration prerequisites
- Appendix B. Commands used by Management Server for deep discovery of enclosures
- Performing the deep discovery of enclosures
- Section VI. Storage Insight SDK Add-on 7.3.1
- Overview of Storage Insight SDK Add-on 7.3.1
- Managing Veritas InfoScale Operations Manager Storage Insight plug-ins
- About creating Storage Insight plug-in
- About discovery script
- About the enclosure discovery command output
- Creating a Storage Insight plug-in
- Editing a Storage Insight plug-in
- Testing a Storage Insight plug-in
- About creating Storage Insight plug-in
- Section VII. Storage Provisioning and Enclosure Migration Add-on 7.3.1
- Provisioning storage
- Creating a storage template using VxFS file systems
- Migrating volumes
- Provisioning storage
- Section VIII. Veritas HA Plug-in for VMware vSphere Web Client
- Introduction to Veritas HA Plug-in for vSphere Web Client
- Installation and uninstallation of Veritas HA Plug-in for vSphere Web Client
- Configurations for Veritas HA Plug-in for vSphere Web Client
- Section IX. Application Migration Add-on
- Introduction to Application Migration Add-on
- Creating and managing an application migration plan
- Understanding application migration operations
Edit Configuration panel options to modify the device discovery
Use this wizard panel to edit the configuration for deep discovery for the following enclosures:
Table: Edit configuration panel options for HITACHI enclosure lists the options for HITACHI enclosures.
Table: Edit configuration panel options for EMC Symmetrix enclosure lists the options for EMC Symmetrix enclosures.
Table: Edit configuration panel options for IBM XIV enclosures lists the options for EMC Symmetrix enclosures.
Table: Edit configuration panel options for NetApp enclosures lists the options for NetApp enclosures.
Table: Edit configuration panel options for EMC CLARiiON enclosures lists the options for EMC CLARiiON enclosures.
Table: Edit configuration panel options for HP EVA enclosure lists the options for HP Enterprise Virtual Array (EVA) enclosures.
Table: Edit configuration panel options for IBM System Storage DS enclosure lists the options for IBM System Storage DS enclosures.
Table: Edit configuration panel options for EMC Celerra enclosure lists the options for EMC Celerra enclosures.
Table: Edit configuration panel options for EMC VNX enclosure lists the options for EMC VNX enclosures.
Table: Edit configuration panel options for EMC VPLEX enclosure lists the options for EMC VPLEX enclosures.
Table: Edit configuration panel options for 3PAR enclosure lists the options for 3PAR enclosures.
Table: Edit configuration panel options for IBM SVC enclosure lists the options for IBM SVC enclosures.
Table: Edit configuration panel options for HITACHI enclosure
Field | Description |
---|---|
Enclosure Vendor | Displays the vendor name of the enclosure. |
Product | Displays the array model for which the deep array discovery is enabled. |
Discovery Method | Displays the discovery method that is used for the discovery of the selected array model. |
Discovery Host | Modify the name of the host. This host must be a part of the Veritas InfoScale Operations Manager Management Server domain. |
HiCommand Server | Modify the name of the HiCommand server. |
Port | Modify the port number of the HiCommand server. By default, the port number is 2001. |
Username | Modify the user name if you have modified the name of the HiCommand server. |
Password | Modify the password if you have modified the name of the HiCommand server. |
Table: Edit configuration panel options for EMC Symmetrix enclosure
Field | Description |
---|---|
Enclosure Vendor | Displays the vendor name of the enclosure. |
Product | Displays the array model for which the deep array discovery is enabled. |
Discovery Method | Displays the discovery method that is used for the discovery of the selected array model. |
Discovery Host | Modify the name of the host. This host must be a part of the Veritas InfoScale Operations Manager Management Server domain. |
SYMAPI Server | Specify the SYMAPI Server name that is configured on the discovery host to discovery EMC Symmetrix enclosures. Use this option if discovery host does not have visibility to gatekeeper devices for Symmetrix enclosures. |
SymCLI Location | |
Use Default | Choose this option if you have stored the SymCLI binaries on the default location. You must ensure that the SymCLI binaries are available on the discovery host. |
Custom | Choose this option if you have stored the SymCLI binaries on any other location. Enter the path to the location in the field. You must ensure that the SymCLI binaries are available on the discovery host. |
Enable performance metering | Enables the performance metering for the enclosure. Clear the check box to disable performance metering. |
Table: Edit configuration panel options for IBM XIV enclosures
Field | Description |
---|---|
Enclosure Vendor | Displays the vendor name of the enclosure. |
Product | Displays the array model for which the deep array discovery is enabled. |
Discovery Method | Displays the discovery method that is used for the discovery of the selected array model. |
Discovery Host | Modify the name of the host. This host must be a part of the Veritas InfoScale Operations Manager Management Server domain. |
IBM XIV Server Name/IP 1 | The IP address for the XIV system. The Storage Insight Add-on uses this IP address to connect to the XIV system using the XCLI utility. |
IBM XIV Server Name/IP 2 | The IP address for the XIV system. The Storage Insight Add-on uses this IP address to connect to the XIV system using the XCLI utility, if the IP address that you have specified in the previous field is not accessible |
IBM XIV Server Name/IP 3 | The IP address for the XIV system. The Storage Insight Add-on uses this IP address to connect to the XIV system using the XCLI utility, if the IP addresses that you have specified in the previous two fields are not accessible |
Username | Modify the user name for the XIV system. |
Password | Modify the password for the XIV system. |
The location of the XCLI utility on the discovery host. You must ensure that the XCLI utility is available on the discovery host. | |
Enable performance metering | Enables the performance metering for the enclosure. Clear the check box to disable performance metering. |
Table: Edit configuration panel options for NetApp enclosures
Field | Description |
---|---|
Enclosure Vendor | Displays the vendor name of the enclosure. |
Product | Displays the array model for which the deep array discovery is enabled. |
Discovery Method | Displays the discovery method that is used for the discovery of the selected array model. |
Discovery Host | Modify the name of the host. This host must be a part of the Veritas InfoScale Operations Manager Management Server domain. |
NetApp Server | Modify the name or the IP address for the NetApp server. |
Port | Modify the port for the NetApp server. Enter 80 for communicating to the NetApp server over HTTP. For communicating to the NetApp server over HTTPS, enter 443. Ensure the port that you specify here is enabled on the enclosure. |
Username | Modify the user name for the enclosure. |
Password | Modify the password for the enclosure. |
Enable NAS discovery | Select the check box to enable the NAS discovery for the NetApp enclosure. |
Enable performance metering | Enables the performance metering for the enclosure. Clear the check box to disable performance metering. Note: It is not supported for NetApp cDOT. |
Table: Edit configuration panel options for EMC CLARiiON enclosures
Enclosure Vendor | Displays the vendor name of the enclosure. |
Product | Displays the array model for which the deep array discovery is enabled. |
Discovery Method | Displays the discovery method that is used for the discovery of the selected array model. |
Discovery Host | Modify the name of the host. This host must be a part of the Veritas InfoScale Operations Manager Management Server domain. |
Storage Array Name/IP | Modify the name or the IP address of the storage enclosure. |
Port | The port for communicating to the EMC CLARiiON enclosure for getting the information. The default port number is 443. |
Username | Modify the user name for the EMC CLARiiON enclosure. |
Password | Modify the password for the EMC CLARiiON enclosure. |
Scope | Specifies the type of the user account on the storage system that you want to log on. The available options are:
|
NAVISEC CLI Location | The location of the NaviSecCLI binary in the discovery host. |
Use Default | Choose this option if you have stored the NaviSecCLI binaries on the default location. You must ensure that the NaviSecCLI binaries are available on the discovery host. |
Custom | Choose this option if you have stored the NaviSecCLI binaries on any other location. Enter the path to the location in the field. You must ensure that the NaviSecCLI binaries are available on the discovery host. |
Use Secure Socket Layer | Select this check box to use the secure socket layer for communicating to the enclosure. If you select this check box, you do not have to enter the credentials again when you perform deep discovery for the EMC CLARiiON enclosures. |
Enable performance metering | Enables the performance metering for the enclosure. Clear the check box to disable performance metering. |
Table: Edit configuration panel options for HP EVA enclosure
Field | Description |
---|---|
Enclosure Vendor | Displays the vendor name of the enclosure. |
Product | Displays the array model for which the deep array discovery is enabled. |
Discovery Method | Displays the discovery method that is used for the discovery of the selected array model. |
Discovery Host | Modify the name of the host. This host must be a part of the Veritas InfoScale Operations Manager Management Server domain. |
Command View Server/IP | Modify the name, or the IP address of the Command View server. |
User Name | Modify the user name for the Command View server if you have modified the name. Note that along with the root or the admin user, a non-admin user can also perform the discovery. |
Password | Modify the password for the Command View server. If you have selected the password file option, you do not need to enter the password. |
SSSU CLI Location | Modify the full path for the Storage Scripting System Utility (SSSU) CLI on the discovery host. |
SSSU Password-File Directory Path | Enter the directory path for the SSSU password file on the discovery host. This file is generated using the SSSU utility. If you have already specified the password in the Password field, this entry is ignored. |
Table: Edit configuration panel options for IBM System Storage DS enclosure
Field | Description |
---|---|
Enclosure Vendor | Displays the vendor name of the enclosure. |
Product | Displays the array model for which the deep array discovery is enabled. |
Discovery Method | Displays the discovery method that is used for the discovery of the selected array model. |
Discovery Host | Modify the name of the host. This host must be a part of the Veritas InfoScale Operations Manager Management Server domain. This host must have DSCLI utility installed on it. It should also be connected to the enclosure. |
Storage array name/IP | Modify the name, or the IP address for the IBM System Storage DS enclosure. |
User Name | Modify the user name for the enclosure. |
Password | Modify the password to access the enclosure. Leave this field blank if the discovery is done using the password file. |
DSCLI Location | Modify the full directory path of the DSCLI utility on the discovery host. |
Password File Path | Enter the full path (including the file name) for the password file on the discovery host. This field is ignored if the password is provided in the Password field. |
Table: Edit configuration panel options for EMC Celerra enclosure
Field | Description |
---|---|
Enclosure Vendor | Displays the vendor name of the enclosure. |
Product | Displays the array model for which the deep array discovery is enabled. |
Discovery Method | Displays the discovery method that is used for the discovery of the selected array model. |
Discovery Host | Modify the name of the host. This host must be a part of the Veritas InfoScale Operations Manager Management Server domain. |
Celerra Control Station | Modify the interface for Celerra communication. |
Username | Modify the user name for the enclosure. |
Password | Modify the password for the enclosure. |
Table: Edit configuration panel options for EMC VNX enclosure
Field | Description |
---|---|
Enclosure Vendor | Displays the vendor name of the enclosure. |
Product | Displays the array model for which the deep array discovery is enabled. |
Discovery Method | Displays the discovery method that is used for the discovery of the selected array model. |
Discovery Host | Modify the name of the host. This host must be a part of the Veritas InfoScale Operations Manager Management Server domain. |
Control Station IP/Name | Modify the name or the IP address of the VNX File. It is optional for VNX Block only device. |
Block IP/Name:Scope | Modify the IP address or name and scope for VNX Block. The IP address or name, and the scope must be separated using colon. It is optional for VNX File only device. |
User Name | Modify the user name for the enclosure. |
Password | Modify the password for the enclosure. |
CLI Location | Modify the Navisphere CLI location. |
Enable performance metering | Enables the performance metering for the enclosure. Clear the check box to disable performance metering. |
Table: Edit configuration panel options for EMC VPLEX enclosure
Field | Description |
---|---|
Enclosure Vendor | Displays the vendor name of the enclosure. |
Product | Displays the array model for which the deep array discovery is enabled. |
Discovery Method | Displays the discovery method that is used for the discovery of the selected array model. |
Discovery Host | Modify the name of the host. This host must be a part of the Veritas InfoScale Operations Manager Management Server domain. |
VPLEX Array Name/IP | Modify the name, or the IP address of the VPLEX enclosure. |
User Name | Modify the user name for the enclosure. To perform the enclosure discovery, you must have administrator privileges. |
Password | Modify the password for the enclosure. |
Port | Modify the communication port for the VPLEX enclosure. The default communication port is 443. |
Table: Edit configuration panel options for 3PAR enclosure
Field | Description |
---|---|
Enclosure Vendor | Displays the vendor name of the enclosure. |
Product | Displays the array model for which the deep array discovery is enabled. |
Discovery Method | Displays the discovery method that is used for the discovery of the selected array model. |
Discovery Host | Modify the name of the host. This host must be a part of the Veritas InfoScale Operations Manager Management Server domain. |
3PAR Enclosure IP/Name | Modify the name or the IP address for the 3PAR enclosure. |
User Name | Modify the user name for the enclosure. |
Password | Modify the password for the enclosure. |
Table: Edit configuration panel options for IBM SVC enclosure
Field | Description |
---|---|
Enclosure Vendor | Displays the vendor name of the enclosure. |
Product | Displays the array model for which the deep array discovery is enabled. |
Discovery Method | Displays the discovery method that is used for the discovery of the selected array model. |
Discovery Host | Modify the name of the discovery host. This host must be a part of the Veritas InfoScale Operations Manager Management Server domain. |
Enclosure IP/Name | Modify the name, or the IP address of the IBM SVC enclosure. |
User Name | Modify the user name for the enclosure. Specify admin as the username for IBM SVC enclosure with version 5.1. |
Password | Change the password for the enclosure. Leave this field blank if the discovery is done using the ssh private key file. |
Certificate Location | Modify the full path for the ssh private key file on the discovery host. |