Veritas InfoScale™ Operations Manager 7.3.1 Add-ons User's Guide
- Section I. VCS Utilities Add-on 7.3.1
- Section II. Distribution Manager Add-on 7.3.1
- Section III. Fabric Insight Add-on 7.3.1
- Section IV. Patch Installer Add-on 7.3.1
- Introduction to Patch Installer Add-on
- Using Patch Installer Add-on
- Section V. Storage Insight Add-on 7.3.1
- Performing the deep discovery of enclosures
- About Storage Insight Add-on
- Adding HITACHI storage enclosures for deep discovery
- Editing the deep discovery configuration for an enclosure
- Monitoring the usage of thin pools
- Monitoring storage array metering data
- Managing LUN classifications
- Appendix A. Enclosure configuration prerequisites
- HITACHI enclosure configuration prerequisites
- EMC Symmetrix storage array configuration prerequisites
- Device setup requirements for EMC Symmetrix arrays
- IBM XIV enclosure configuration prerequisites
- NetApp storage enclosure configuration prerequisites
- EMC CLARiiON storage enclosures configuration prerequisites
- Hewlett-Packard Enterprise Virtual Array (HP EVA) configuration prerequisites
- IBM System Storage DS enclosure configuration prerequisites
- IBM SVC enclosure configuration prerequisites
- EMC Celerra enclosure configuration prerequisites
- EMC VNX storage enclosure configuration prerequisites
- EMC VPLEX storage enclosure configuration prerequisites
- Appendix B. Commands used by Management Server for deep discovery of enclosures
- Performing the deep discovery of enclosures
- Section VI. Storage Insight SDK Add-on 7.3.1
- Overview of Storage Insight SDK Add-on 7.3.1
- Managing Veritas InfoScale Operations Manager Storage Insight plug-ins
- About creating Storage Insight plug-in
- About discovery script
- About the enclosure discovery command output
- Creating a Storage Insight plug-in
- Editing a Storage Insight plug-in
- Testing a Storage Insight plug-in
- About creating Storage Insight plug-in
- Section VII. Storage Provisioning and Enclosure Migration Add-on 7.3.1
- Provisioning storage
- Creating a storage template using VxFS file systems
- Migrating volumes
- Provisioning storage
- Section VIII. Veritas HA Plug-in for VMware vSphere Web Client
- Introduction to Veritas HA Plug-in for vSphere Web Client
- Installation and uninstallation of Veritas HA Plug-in for vSphere Web Client
- Configurations for Veritas HA Plug-in for vSphere Web Client
- Section IX. Application Migration Add-on
- Introduction to Application Migration Add-on
- Creating and managing an application migration plan
- Understanding application migration operations
About Brocade switch discovery
Brocade switches are discovered using the following methods:
Using HTTP communication
Using ODBC connection to Brocade Network Advisor (BNA)
The following information is discovered about the Brocade switches:
Switches, multi-protocol routers, and the access gateways
Active zones and their zone members
Virtual switches
Inter-switch and NPV/NPIV links between the switches
Switch to multi-protocol router connections
Brocade switch discovery prerequisites are as follows:
Principal switch requirement: Fabric OS version 6.3.x, or later
Subordinate switch requirements: Fabric OS version 5.3.2, or later
Seed Switch: Fabric OS version 5.3.2, or later
Minimum guest-level access is required for the discovery.
All switches in the fabric must have the same user credentials for a successful switch discovery. The BNA credentials are the BNA database credentials; not the BNA application login credentials.
For the discovery using HTTP communication, ensure that HTTP port 80 is open. For the discovery using Brocade Network Advisor (BNA), postgress port 5432 should be open.
For BNA based discovery, the BNA version should be 11.x, or later. For HTTP based discovery, the switch firmware version should be 5.3.x, or later.
Note:
With some versions of BNA (for example version 12.x and later), additional steps are required on the BNA server to enable the Veritas InfoScale Operations Manager discovery host to discover the switches. Change the BNA database client authentication file (pg_hba.conf
) to allow the discovery host to connect to the BNA database. The file is located at C:\Program Files\Network Advisor 12.0.0\data\databases\pg_hba.conf
.