Notifier Manager agent error messages
The agent failed to start the specified notifier process. This could occur due to an incorrect path name specified in the configuration, low memory on the system, or a Windows-specific error, defined by the corresponding error code.
Recommended Action: Verify the configuration definition of the agent. Verify that the system has adequate memory.
The notifier process was terminated.
Recommended Action: VCS marks the resource as faulted. Wait, then try to bring the resource online again.
The agent could not terminate the notifier process. This indicates a Windows-specific error, defined by the corresponding error code.
Recommended Action: Try terminating the process manually using Task Manager.
The agent could not terminate the notifier process. This indicates a Windows-specific error, defined by the corresponding error code.
Recommended Action: Try terminating the process manually using Task Manager.
Invalid severity level specified for SNMP notifications,
Recommended Action: Verify the severity level specified in the SnmpConsoles attribute has "Warning", "Information", "Error", or "SevereError" as the severity level.
Invalid severity level specified for SMTP notifications,
Recommended Action: Verify the severity level specified in the SmtpRecipients attribute has "Warning", "Information", "Error", or "SevereError" as the severity level.
Invalid values specified for SNMP and SMTP attributes.
Recommended Action: Verify the attributes defined in the configuration file are assigned valid values.
Invalid values specified for SNMP and SMTP attributes.
Recommended Action: Verify the attributes defined in the configuration file are assigned valid values.
The value for VCS_HOME environment variable is incorrect.
Recommended Action: Verify the value for the VCS_HOME environment variable. Contact Veritas Technical Support if the problem persists.