Storage Foundation for Oracle® RAC 7.3.1 Administrator's Guide - Linux
- Section I. SF Oracle RAC concepts and administration
- Overview of Storage Foundation for Oracle RAC
- About Storage Foundation for Oracle RAC
- Component products and processes of SF Oracle RAC
- About Virtual Business Services
- Administering SF Oracle RAC and its components
- Administering SF Oracle RAC
- Starting or stopping SF Oracle RAC on each node
- Administering VCS
- Administering I/O fencing
- About the vxfentsthdw utility
- Testing the coordinator disk group using the -c option of vxfentsthdw
- About the vxfenadm utility
- About the vxfenclearpre utility
- About the vxfenswap utility
- Administering the CP server
- Administering CFS
- Administering CVM
- Changing the CVM master manually
- Administering Flexible Storage Sharing
- Backing up and restoring disk group configuration data
- Administering SF Oracle RAC global clusters
- Administering SF Oracle RAC
- Overview of Storage Foundation for Oracle RAC
- Section II. Performance and troubleshooting
- Troubleshooting SF Oracle RAC
- About troubleshooting SF Oracle RAC
- Troubleshooting I/O fencing
- Fencing startup reports preexisting split-brain
- Troubleshooting CP server
- Troubleshooting server-based fencing on the SF Oracle RAC cluster nodes
- Issues during online migration of coordination points
- Troubleshooting Cluster Volume Manager in SF Oracle RAC clusters
- Troubleshooting CFS
- Troubleshooting interconnects
- Troubleshooting Oracle
- Troubleshooting ODM in SF Oracle RAC clusters
- Prevention and recovery strategies
- Tunable parameters
- Troubleshooting SF Oracle RAC
- Section III. Reference
Cluster ID on the I/O fencing key of coordinator disk does not match the local cluster's ID
If you accidentally assign coordinator disks of a cluster to another cluster, then the fencing driver displays an error message similar to the following when you start I/O fencing:
000068 06:37:33 2bdd5845 0 ... 3066 0 VXFEN WARNING V-11-1-56 Coordinator disk has key with cluster id 48813 which does not match local cluster id 57069
The warning implies that the local cluster with the cluster ID 57069 has keys. However, the disk also has keys for cluster with ID 48813 which indicates that nodes from the cluster with cluster id 48813 potentially use the same coordinator disk.
You can run the following commands to verify whether these disks are used by another cluster. Run the following commands on one of the nodes in the local cluster. For example, on sys1:
sys1> # lltstat -C 57069 sys1> # cat /etc/vxfentab /dev/vx/rdmp/disk_7 /dev/vx/rdmp/disk_8 /dev/vx/rdmp/disk_9 sys1> # vxfenadm -s /dev/vx/rdmp/disk_7 Reading SCSI Registration Keys... Device Name: /dev/vx/rdmp/disk_7 Total Number Of Keys: 1 key[0]: [Numeric Format]: 86,70,48,49,52,66,48,48 [Character Format]: VFBEAD00 [Node Format]: Cluster ID: 48813 Node ID: 0 Node Name: unknown
Where disk_7, disk_8, and disk_9 represent the disk names in your setup.
Recommended action: You must use a unique set of coordinator disks for each cluster. If the other cluster does not use these coordinator disks, then clear the keys using the vxfenclearpre command before you use them as coordinator disks in the local cluster.