Storage Foundation for Sybase ASE CE 7.4 Administrator's Guide - Linux
- Overview of Storage Foundation for Sybase ASE CE
- About Storage Foundation for Sybase ASE CE
- About SF Sybase CE components
- About optional features in SF Sybase CE
- Administering SF Sybase CE and its components
- Administering SF Sybase CE
- Starting or stopping SF Sybase CE on each node
- Administering VCS
- Administering I/O fencing
- About the vxfentsthdw utility
- Testing the coordinator disk group using the -c option of vxfentsthdw
- About the vxfenadm utility
- About the vxfenclearpre utility
- About the vxfenswap utility
- Administering CVM
- Changing the CVM master manually
- Administering CFS
- Administering the Sybase agent
- Administering SF Sybase CE
- Troubleshooting SF Sybase CE
- About troubleshooting SF Sybase CE
- Troubleshooting I/O fencing
- Fencing startup reports preexisting split-brain
- Troubleshooting Cluster Volume Manager in SF Sybase CE clusters
- Troubleshooting interconnects
- Troubleshooting Sybase ASE CE
- Prevention and recovery strategies
- Prevention and recovery strategies
- Managing SCSI-3 PR keys in SF Sybase CE cluster
- Prevention and recovery strategies
- Tunable parameters
- Appendix A. Error messages
VXFEN driver error messages
Table: VXFEN driver error messages contains VXFEN driver error messages. In addition to VXFEN driver error messages, informational messages can also be displayed.
Table: VXFEN driver error messages
Message | Explanation |
---|---|
Unable to register with coordinator disk with serial number: xxxx | This message appears when the vxfen driver is unable to register with one of the coordinator disks. The serial number of the coordinator disk that failed is displayed. |
Unable to register with a majority of the coordinator disks. Dropping out of cluster. | This message appears when the vxfen driver is unable to register with a majority of the coordinator disks. The problems with the coordinator disks must be cleared before fencing can be enabled. This message is preceded with the message "VXFEN: Unable to register with coordinator disk with serial number xxxx." |
There exists the potential for a preexisting split-brain. The coordinator disks list no nodes which are in the current membership. However, they, also list nodes which are not in the current membership. I/O Fencing Disabled! | This message appears when there is a preexisting split-brain in the cluster. In this case, the configuration of vxfen driver fails. Clear the split-brain before configuring vxfen driver. |
Unable to join running cluster since cluster is currently fencing a node out of the cluster | This message appears while configuring the vxfen driver, if there is a fencing race going on in the cluster. The vxfen driver can be configured by retrying after some time (after the cluster completes the fencing). |