Please enter search query.
Search <book_title>...
Storage Foundation for Oracle® RAC 7.3.1 Administrator's Guide - Linux
Last Published:
2018-01-16
Product(s):
InfoScale & Storage Foundation (7.3.1)
- Section I. SF Oracle RAC concepts and administration
- Overview of Storage Foundation for Oracle RAC
- About Storage Foundation for Oracle RAC
- Component products and processes of SF Oracle RAC
- About Virtual Business Services
- Administering SF Oracle RAC and its components
- Administering SF Oracle RAC
- Starting or stopping SF Oracle RAC on each node
- Administering VCS
- Administering I/O fencing
- About the vxfentsthdw utility
- Testing the coordinator disk group using the -c option of vxfentsthdw
- About the vxfenadm utility
- About the vxfenclearpre utility
- About the vxfenswap utility
- Administering the CP server
- Administering CFS
- Administering CVM
- Changing the CVM master manually
- Administering Flexible Storage Sharing
- Backing up and restoring disk group configuration data
- Administering SF Oracle RAC global clusters
- Administering SF Oracle RAC
- Overview of Storage Foundation for Oracle RAC
- Section II. Performance and troubleshooting
- Troubleshooting SF Oracle RAC
- About troubleshooting SF Oracle RAC
- Troubleshooting I/O fencing
- Fencing startup reports preexisting split-brain
- Troubleshooting CP server
- Troubleshooting server-based fencing on the SF Oracle RAC cluster nodes
- Issues during online migration of coordination points
- Troubleshooting Cluster Volume Manager in SF Oracle RAC clusters
- Troubleshooting CFS
- Troubleshooting interconnects
- Troubleshooting Oracle
- Troubleshooting ODM in SF Oracle RAC clusters
- Prevention and recovery strategies
- Tunable parameters
- Troubleshooting SF Oracle RAC
- Section III. Reference
Low-level communication: port relationship between GAB and processes
All components in SF Oracle RAC use GAB for communication. Each process that wants to communicate with a peer process on other nodes registers with GAB on a specific port. This registration enables communication and notification of membership changes. For example, the VCS engine (HAD) registers on port h. HAD receives messages from peer HAD processes on port h. HAD also receives notification when a node fails or when a peer process on port h unregisters.
Some modules use multiple ports for specific communications requirements. For example, CVM uses multiple ports to allow communications by kernel and user-level functions in CVM independently.