Performance metering of enclosures may not work properly after failover (2814844)
If Management Server is configured in high availability environment, and if the enclosure is discovered through Storage Insight Add-on then, performance metering of the enclosure may not work properly after failover, until the next discovery cycle.
The following may occur until the next discovery cycle:
Performance metering does not start for the enclosure.
Performance charts for which the duration is selected as Live, do not show any information.
Incorrect error messages may be displayed in the performance chart.
Workaround:
You need to manually refresh the enclosure discovery.
To manually refresh the enclosure discovery
- In the Home page on the Management Server console, click Settings.
- Click Device.
- In the Enclosure Configuration tab locate the enclosure.
- Right-click the enclosure and select Refresh Configuration.