Veritas NetBackup™ 5330 Appliance Product Description
- NetBackup 5330 Appliance overview
- NetBackup 5330 Appliance system features
- NetBackup 5330 Appliance compute node disk drive configurations
- About NetBackup 5330 Appliance storage shelves
- NetBackup 5330 Appliance cables
- Appendix A. Technical specifications, standards, and compliance information
NetBackup 5330 Appliance system technical specifications
Table: NetBackup 5330 Appliance specifications
Parameter | Description |
---|---|
Rack information | 19" EIA compliant The rack installation height is the space occupied by an appliance in a rack cabinet. The rack height for the appliance is 2U (1U = 44.5 cm). Install the appliance in a rack cabinet that is 19 inches (1 inch = 2.54 cm) wide and 39.37 inches (100 cm) deep. |
Weight | Approximately 30 kg (66 lbs) Note: The maximum weight of the NetBackup 5330 Appliance includes the eight disk drive modules, eight disk drive carriers, and two power modules. Note: When shipping the appliance, the total weight of the system equals the sum of the maximum weight of a device and the maximum weight of the transportation materials. |
Processors
| |
Dimensions | Height: 8.76 cm (3.45") (approximately 2U) Width: 43.8 cm (17.24") Depth: 69.59 cm (27.39") |
Power consumption | 750 watts maximum |
AC power requirements | 110 VAC or 220 VAC 100 - 110 VAC at 50/60 Hz 8.2 A 200 - 220 VAC at 50/60 Hz 4.4 A |
AC power cable | Specification: IEC-60320-C14 to IEC-60320-C13, 10A/250V, Black, 4 ft The IEC-60320-C14 plugs into a Power Distribution Unit. The IEC-60320-C13 plugs into an appliance or storage shelf power supply. Note: If your power distribution unit is not compatible with the IEC-60320-C14 plug, then Veritas recommends that you purchase your power cable locally. Make sure the power cable meets or exceed the indicated power rating. See Power cables. |
Inherent availability of the system | ≥ 99.95% |
Operating temperature | +10°C to +35°C with the maximum rate of change not to exceed 10°C per hour |
Non-operating temperature | -40°C to +70°C |
Non-operating humidity | 90%, non-condensing at 35°C |
Acoustic noise | Sound power: 7.0 dB in operating condition at typical office ambient temperature. (23°C +/- 2) |
System Cooling Requirement | 460 watts maximum - 1570 BTU/hour 750 watts maximum - 2559 BTU/hour |
The technical specifications for the NetBackup 5330 Appliance Primary Storage Shelf and for the NetBackup 5330 Appliance Expansion Storage Shelf are as follows.
Table: Primary Storage Shelf and Expansion Storage Shelf technical specifications
Parameter | Description |
---|---|
Rack information | 4U |
Weight | Approximately 105.2 kg (232 lb) with the 60 disk drives installed Approximately 80 kg (176 lb) without the disk drives Note: The maximum weight of the storage shelves includes 60 disk drive slots, two power canisters, and two fan canisters. |
Dimensions | Length: 82.55 cm (32.50") Width: 48.28 cm (19.00") Height: 17.78 cm (7.00") (approximately 4U) |
Overall maximum AC currents (agency ratings) | 7.56 A at 200 VAC 6.3 A at 240 VAC |
AC power requirements | Input voltage: 200 - 240 VAC Frequency: Range 50 Hz to 60 Hz Typical operating current: Range 4.9 A to 5.75 A Nameplate rating: Range 6.3 A to 7.56 A |
Primary Storage Shelf Power ratings and heat dissipation including two fan canisters, two power canisters, 60 disk drives, and two RAID canisters. | 1135 watts (typical) 1222 watts (maximum) Cooling BTU/hour: 3873 (typical) Cooling BTU/hour: 4180 (maximum) |
Expansion Storage Shelf Power ratings and heat dissipation including two fan canisters, two power canisters, 60 disk drives, and two expansion canisters. | 847 watts (typical) 1222 watts (maximum) Cooling BTU/hour: 2890 (typical) Cooling BTU/hour: 4180 (maximum) |
NetBackup 5330 Appliance compute node with a Primary Storage Shelf connected | 1595 watts (typical) 1972 watts (maximum) Cooling BTU/hour: 5442 (typical) Cooling BTU/hour: 6739 (maximum) |
NetBackup 5330 Appliance compute node with both a Primary Storage Shelf and an Expansion Storage Shelf connected | 2442 watts (typical) 3194 watts (maximum) Cooling BTU/hour: 8332 (typical) Cooling BTU/hour: 10919 (maximum) |
Sound levels | Sound power (standby operation): 6.5 bels Sound power (normal operation): 6.8 bels Sound pressure: 68 dB |