Veritas NetBackup™ 5330 Appliance Product Description
- NetBackup 5330 Appliance overview
- NetBackup 5330 Appliance system features
- NetBackup 5330 Appliance compute node disk drive configurations
- About NetBackup 5330 Appliance storage shelves
- NetBackup 5330 Appliance cables
- Appendix A. Technical specifications, standards, and compliance information
Environmental specifications
The following table lists the requirements for the NetBackup 5330 Appliance and the storage shelves.
Table: Environmental specifications
Component | Requirement |
---|---|
Operating temperature | 10°C to 35°C (50°F to 95°F) |
Storage temperature | -40°C to 70°C (-40°F to 158°F) |
Transportation temperature | -40°C to 70°C (-40°F to 158°F) |
Temperature gradient | 10°C/h |
Operating humidity | 10%RH to 85%RH |
Operating altitude | -30 meters to 3,000 meters In altitudes from -60 meters to +1,800 meters, the ambient temperature ranges from 5°C to 35°C. When the altitude ranges from 1,800 meters to 3,000 meters, the environment temperature decreases by 0.6°C when the altitude increases by 100 meters. |
Storage altitude | -30 meters to 3,000 meters |
Noise | < 72 A-weighted decibel This value reflects the maximum noise of the appliance when the ambient temperature is 25°C. |