NetBackup IT Analytics Data Collector Installation and Configuration Guide for Veritas NetBackup
- Introduction
- Configure a NetBackup IT Analytics Distributed Data Collector on a NetBackup Primary Server
- Configure Data Collector on non-clustered NetBackup 10.4 and later primary server
- Configure Data Collector on non-clustered NetBackup 10.1.1, 10.2, 10.2.01, 10.3 or 10.3.0.1 primary server
- Configure a Veritas NetBackup Data Collector Policy
- Configuring file analytics in NetBackup Data Collector policy
- Installing the Data Collector software
- Configure SSL
- Centralized Data Collector for NetBackup - Prerequisites, Installation, and Configuration
- Step-1: Choose operating system and complete prerequisites
- Step-5: SSH/WMI
- Upgrading Data Collector Locally
- Clustering Data Collectors with VCS and Veritas NetBackup (RHEL)
- Clustering Data Collectors with VCS and Veritas NetBackup (Windows)
- Install and configure NetBackup IT Analytics Data Collector on MSCS environment
- Data Collector Policy Migration
- Pre-Installation setup for Veritas NetBackup appliance
- Pre-installation setup for Veritas Flex Appliance
- Data Collector Troubleshooting
- Host resources: Check host connectivity using standard SSH
- Host resources: Generating host resource configuration files
- Configuring parameters for SSH
- Appendix A. Configure Appliances
- Appendix B. Load historic events
- Load Veritas NetBackup events
- Appendix C. Firewall configuration: Default ports
- Appendix D. CRON Expressions for Policy and Report Schedules
- Appendix E. Maintenance Scenarios for Message Relay Server Certificate Generation
Verification of upgrade bundle available on Data Collector server
SmartUpdaterThread validates both bundles in the following order.
Version comparison: Bundle's version is compared against the expected upgrade version received from NetBackup IT Analytics Data Receiver.
Checksum verification: Checksum is retrieved from a Data Receiver, and compared against the one generated using the bundle available locally on the Data Collector server.
Signed Jar verification: Java utility
jarsigner
is used to verify whether the bundle is signed or not.At any point, if the verification fails, the upgrade fails and bundles are deleted from the Data Collector server.
When the NetBackup IT Analytics Portal is upgraded successfully to a newer version, and subsequently, the Data Collector upgrade fails due to errors like:
Collector bundle download failed for 11.2.1.03 Premature EOF
Upgrade Manager upgrade failed. Exception is : Premature EOF
These errors indicate that the upgrade bundle could not be downloaded successfully on to the Data Collector server due to slow network/low bandwidth.
Prerequisites:
These errors indicate that the upgrade bundle could not be downloaded successfully on to the Data Collector server due to slow network/low bandwidth.
Requires access permissions to copy files to/from Data Collector Server and Portal Server.
Notations:
<PORTAL_APTARE_HOME> is where Portal is installed. Default value:
Linux Portal:
/opt/aptare
Windows Portal: <drive>:\opt\aptare
<DC_APTARE_HOME> is where the Data Collector is installed. Default values:
Data Collector on Linux: /user/openv/analyticscollector
Data Collectors on Windows: C:\Program Files\Veritas\AnalyticsCollector
<OS> is the Operating System where Data Collector software is installed.
<version> is the NetBackup IT Analytics version (Portal is on this version)