Veritas™ 5360 Appliance Product Description Guide
- About the Veritas 5360 Appliance
- Compute node drive configurations
- About the 5360 Appliance control panel
- Veritas 5360 Appliance I/O configuration options
- About the Veritas 5U84 Storage Shelves
- About Veritas 5360 Appliance storage shelves
- About the 5U84 Primary Storage Shelf and 5U84 Expansion Storage Shelf rear components
- Veritas 5360 Appliance and 5U84 Storage Shelf cables
- Appendix A. Technical specifications, Environmental/Protocol standards, and Compliance standards
Compute node drive configurations
The Veritas 5360 Appliance compute node contains three Opal-compliant SED only 1.92 TB NVMe SSDs. Each SSD is accessible from the compute node's front panel. An embedded RAID controller on the compute node's mainboard configures two of the three SATA SSDs into a RAID1 volume.
The two RAID1 volumes contain the appliance operating system, the operating system swap file, the Flex application, and the logs. You can hot-swap one of these drives at a time if a drive becomes problematic. Replacements must be SED capable and of the same capacity. Or in other words, only like-for-like replacements are permitted.
The drives in slot 1 and slot 2 are configured as RAID1 with slot 3 as the hot spare. If a drive in the RAID volume experiences a hardware error, the appliance automatically initiates a RAID rebuild operation. During the rebuild operation, the appliance dynamically accesses the hot-spare drive and uses it to rebuild the RAID volume.
Table: Veritas 5360 Appliance compute node front panel drive configurations
Slot | RAID level | Drive size (TB) | Drive role |
---|---|---|---|
0, 1 | RAID1 | 1.92 TB | Operating system and log volume |
2 | RAID1 | 1.92 TB | Operating system/log hot spare |
3-7 | RAID1 | - | blank |