NetBackup™ Commands Reference Guide

Last Published:
Product(s): NetBackup (10.0)
  1. Introduction
    1.  
      About NetBackup commands
    2.  
      Navigating multiple menu levels
    3.  
      NetBackup command conventions
    4.  
      NetBackup Media Manager command notes
    5.  
      IPV6 updates
  2. Appendix A. NetBackup Commands
    1.  
      acsd
    2.  
      add_media_server_on_clients
    3.  
      backupdbtrace
    4.  
      backuptrace
    5.  
      bmrc
    6.  
      bmrconfig
    7.  
      bmrepadm
    8.  
      bmrprep
    9.  
      bmrs
    10.  
      bmrsrtadm
    11.  
      bp
    12.  
      bparchive
    13.  
      bpbackup
    14.  
      bpbackupdb
    15.  
      bpcatarc
    16.  
      bpcatlist
    17.  
      bpcatres
    18.  
      bpcatrm
    19.  
      bpcd
    20.  
      bpchangeprimary
    21.  
      bpcleanrestore
    22.  
      bpclient
    23.  
      bpclimagelist
    24.  
      bpclntcmd
    25.  
      bpclusterutil
    26.  
      bpcompatd
    27.  
      bpconfig
    28.  
      bpdbjobs
    29.  
      bpdbm
    30.  
      bpdgclone
    31.  
      bpdown
    32.  
      bpduplicate
    33.  
      bperror
    34.  
      bpexpdate
    35.  
      bpfis
    36.  
      bpflist
    37.  
      bpgetconfig
    38.  
      bpgetdebuglog
    39.  
      bpimage
    40.  
      bpimagelist
    41.  
      bpimmedia
    42.  
      bpimport
    43.  
      bpinst
    44.  
      bpkeyfile
    45.  
      bpkeyutil
    46.  
      bplabel
    47.  
      bplist
    48.  
      bpmedia
    49.  
      bpmedialist
    50.  
      bpminlicense
    51.  
      bpnbat
    52.  
      bpnbaz
    53.  
      bppficorr
    54.  
      bpplcatdrinfo
    55.  
      bpplclients
    56.  
      bppldelete
    57.  
      bpplinclude
    58.  
      bpplinfo
    59.  
      bppllist
    60.  
      bpplsched
    61.  
      bpplschedrep
    62.  
      bpplschedwin
    63.  
      bppolicynew
    64.  
      bpps
    65.  
      bprd
    66.  
      bprecover
    67.  
      bprestore
    68.  
      bpretlevel
    69.  
      bpschedule
    70.  
      bpschedulerep
    71.  
      bpsetconfig
    72.  
      bpstsinfo
    73.  
      bpstuadd
    74.  
      bpstudel
    75.  
      bpstulist
    76.  
      bpsturep
    77.  
      bptestbpcd
    78.  
      bptestnetconn
    79.  
      bptpcinfo
    80.  
      bpup
    81.  
      bpverify
    82.  
      cat_convert
    83.  
      cat_export
    84.  
      cat_import
    85.  
      configureCerts
    86.  
      configureMQ
    87.  
      configurePorts
    88.  
      configureWebServerCerts
    89.  
      create_nbdb
    90.  
      csconfig cldinstance
    91.  
      csconfig cldprovider
    92.  
      csconfig meter
    93.  
      csconfig reinitialize
    94.  
      csconfig throttle
    95.  
      duplicatetrace
    96.  
      importtrace
    97.  
      jbpSA
    98.  
      jnbSA
    99.  
      ltid
    100.  
      mklogdir
    101.  
      nbauditreport
    102.  
      nbcallhomeproxyconfig
    103.  
      nbcatsync
    104.  
      NBCC
    105.  
      NBCCR
    106.  
      nbcertcmd
    107.  
      nbcertupdater
    108.  
      nbcldutil
    109.  
      nbcloudrestore
    110.  
      nbcomponentupdate
    111.  
      nbcplogs
    112.  
      nbcredkeyutil
    113.  
      nbdb_admin
    114.  
      nbdb_backup
    115.  
      nbdb_move
    116.  
      nbdb_ping
    117.  
      nbdb_restore
    118.  
      nbdb_unload
    119.  
      nbdb2adutl
    120.  
      nbdbms_start_server
    121.  
      nbdbms_start_stop
    122.  
      nbdc
    123.  
      nbdecommission
    124.  
      nbdelete
    125.  
      nbdeployutil
    126.  
      nbdevconfig
    127.  
      nbdevquery
    128.  
      nbdiscover
    129.  
      nbdna
    130.  
      nbemm
    131.  
      nbemmcmd
    132.  
      nbfindfile
    133.  
      nbfirescan
    134.  
      nbfp
    135.  
      nbftadm
    136.  
      nbftconfig
    137.  
      nbgetconfig
    138.  
      nbhba
    139.  
      nbholdutil
    140.  
      nbhostidentity
    141.  
      nbhostmgmt
    142.  
      nbhypervtool
    143.  
      nbidpcmd
    144.  
      nbimageshare
    145.  
      nbinstallcmd
    146.  
      nbjm
    147.  
      nbkmiputil
    148.  
      nbkmscmd
    149.  
      nbkmsutil
    150.  
      nboraadm
    151.  
      nborair
    152.  
      nbpem
    153.  
      nbpemreq
    154.  
      nbmlb
    155.  
      nbperfchk
    156.  
      nbplupgrade
    157.  
      nbrb
    158.  
      nbrbutil
    159.  
      nbregopsc
    160.  
      nbreplicate
    161.  
      nbrepo
    162.  
      nbrestorevm
    163.  
      nbseccmd
    164.  
      nbserviceusercmd
    165.  
      nbsetconfig
    166.  
      nbsmartdiag
    167.  
      nbsnapimport
    168.  
      nbsnapreplicate
    169.  
      nbsqladm
    170.  
      nbstl
    171.  
      nbstlutil
    172.  
      nbstop
    173.  
      nbsu
    174.  
      nbsvrgrp
    175.  
      netbackup_deployment_insights
    176.  
      resilient_clients
    177.  
      restoretrace
    178.  
      stopltid
    179.  
      tldd
    180.  
      tldcd
    181.  
      tpautoconf
    182.  
      tpclean
    183.  
      tpconfig
    184.  
      tpext
    185.  
      tpreq
    186.  
      tpunmount
    187.  
      verifytrace
    188.  
      vltadm
    189.  
      vltcontainers
    190.  
      vlteject
    191.  
      vltinject
    192.  
      vltoffsitemedia
    193.  
      vltopmenu
    194.  
      vltrun
    195.  
      vmadd
    196.  
      vmchange
    197.  
      vmcheckxxx
    198.  
      vmd
    199.  
      vmdelete
    200.  
      vmoprcmd
    201.  
      vmphyinv
    202.  
      vmpool
    203.  
      vmquery
    204.  
      vmrule
    205.  
      vmupdate
    206.  
      vnetd
    207.  
      vssat
    208.  
      vwcp_manage
    209.  
      vxlogcfg
    210.  
      vxlogmgr
    211.  
      vxlogview
    212.  
      W2KOption
  3.  
    Index

Name

bptpcinfo — discover SAN devices and creates 3pc.conf file

SYNOPSIS

bptpcinfo [-a] [-c] [-h] [-u] [-r] [-v] [-d disk_device_directory] [-t tape_device_directory] [-p physical_device] [-o output_file_name] [-o -]

 

The directory path to this command is /usr/openv/netbackup/bin/

DESCRIPTION

This command operates only on UNIX systems.

The bptpcinfo command discovers all the disk and the tape devices on Fibre Channel and SCSI connections. It provides information about each device (one line per device). By default, this command writes the information to the following file:

  /usr/openv/volmgr/database/3pc.conf

Note:

For off-host backup (Third-Party Copy Device or NetBackup media server backup methods), a 3pc.conf file must exist at /usr/openv/volmgr/database.

At the start of a backup, using the Third-Party Copy Device or NetBackup media server method, NetBackup automatically runs this command to create the 3pc.conf file if the file does not already exist. This file is complete and you do not need to rerun this command if any of the following is true:

  • The backup uses the NetBackup media server backup method.

  • You use the Third-Party Copy Device backup method and all required devices (such as disks, tapes, and third-party copy devices) support identification descriptors.

If any of the devices does not support identification descriptors, run the bptpcinfo command manually to create the 3pc.conf file. Then edit the file as explained in the SAN Configuration chapter of the NetBackup Snapshot Client Administrator's Guide.

OPTIONS

-a

Discovers all the disk and the tape devices on the Fibre Channel and SCSI connections. It adds entries in the 3pc.conf file (or alternate output file that is specified with the -o option). The -a option lists all devices in /dev/rdsk and /dev/rmt.

-c

Checks for syntax errors in an already existing 3pc.conf file (in /usr/openv/volmgr/database). If the 3pc.conf file does not exist, a message states that it cannot open the file. In that case, use other command options to create the file. Note that if -c is specified, any other options are ignored.

The -c option checks for syntax errors such as the following: missing spaces between entries, missing keywords (such as a worldwide name without "w="), or a worldwide name that is not 16 digits in length. Any such errors can cause the backup to fail.

-h

Displays the bptpcinfo usage statement.

-u

Discovers all the disk devices and the tape devices on the Fibre Channel and SCSI connections. It also adds entries in the 3pc.conf file (or alternate the output file that is specified with the -o option) for new devices that are found. If the 3pc.conf file does not exist, the -u option fails (use -a instead).

Note:

To remove obsolete entries, use -r instead of -u. (The -u and -r options cannot be used together.)

-r

Removes any obsolete entries in the 3pc.conf file (or the alternate output file that is specified with the -o option). An obsolete entry is one that no longer corresponds to any devices on the Fibre Channel or SCSI connections.

Note:

The -r option does not add entries to the 3pc.conf file for new or reconfigured devices. To add entries, use the -u option. (The -u and -r options cannot be used together.)

-v

Specifies the verbose mode, which causes bptpcinfo to list information on its discovery progress. The information is written to the screen, not to the 3pc.conf file.

You can select the -v option to track problems in device discovery.

-d disk_device_directory

Discovers all disks in the specified directory (usually /dev/rdsk on Solaris or Hewlett Packard Enterprise, and /dev on AIX) and creates new entries in the 3pc.conf file. Or, it creates new entries in the alternate output file that is specified with the -o option by overwriting any current entries.

To avoid overwriting the 3pc.conf file, use the -d option with the -u option. When -d and -u are combined, the new disk entries are added to the existing entries.

-t tape_device _directory

Discovers all tape drives in the specified directory (usually /dev/rmt on Solaris or Hewlett Packard Enterprise, and /dev on AIX) and creates new entries in the 3pc.conf file. Or, it creates new entries in the alternate output file that is specified with the -o option by overwriting any current entries.

To avoid overwriting the 3pc.conf file, use the -t option with the -u option. When -t and -u are combined, the new tape entries are added to the existing entries.

-p physical_device

Creates an entry for a physical device in the 3pc.conf file, if the specified device is discovered. Or, it creates new entries in the alternate output file that is specified with the -o option by overwriting any current entries.

To avoid overwriting the 3pc.conf file, use the -p option with the -u option. When -p and -u are combined, the new entry is added to the existing entries.

-o output_file_name

-o specifies an alternate (usually temporary) path for the bptpcinfo command output. If this option is not specified, the default is /usr/openv/volmgr/database/3pc.conf.

-o -

Sends the output to the screen. Note the space before the second hyphen.

EXAMPLES

Example 1 - Discover all the source and the destination devices on the SAN and create the required 3pc.conf file in /usr/openv/volmgr/database.

# bptpcinfo -a

Example 2 - Discover all the source and the destination devices on the SAN, and send the output to the screen.

# bptpcinfo -a -o -

Sample output:

devid [p=devpath]  [s=sn] [n=npid] [l=lun] [w=wwpn] [i=iddesc]
1     p=/dev/rdsk/c1t11d3s2   s=SEAGATE:ST19171N:LAE82305 l=3
2     p=/dev/rdsk/c1t13d4s2   s=SEAGATE:ST19101W:NH022724 l=4
3     p=/dev/rdsk/c1t20d0s2   s=HITACHI:OPEN-9:60159003900 l=0
4     p=/dev/rdsk/c1t20d1s2   s=HITACHI:OPEN-9:60159000000 l=1
5     p=/dev/rdsk/c1t20d2s2   s=HITACHI:OPEN-9:60159000100 l=2
6     p=/dev/rdsk/c1t20d3s2   s=HITACHI:OPEN-9-CM:60159001C00 l=3
7     p=/dev/rdsk/c1t20d4s2   s=HITACHI:OPEN-9:60159002B00 l=4
8     p=/dev/rdsk/c1t20d5s2   s=HITACHI:OPEN-9:60159002C00 l=5

Example 3 - Discover the devices in the /dev/rmt directory (/dev on AIX) and send the output to the screen:

On Solaris or Hewlett Packard Enterprise:

# bptpcinfo -t /dev/rmt -o -

Sample output:

devid [p=devpath]     [s=sn]  [n=npid]      [l=lun] [w=wwpn] [i=iddesc]
0     p=/dev/rmt/0cbn  s=QUANTUM:DLT8000:CX949P0164  l=1 i=10200E09E6000000868
1     p=/dev/rmt/1cbn  s=QUANTUM:DLT8000:CX949P1208  l=2 i=10200E09E6000001381
2     p=/dev/rmt/4cbn  s=QUANTUM:DLT8000:CX940P2790  l=2 i=1031000005013E000D3
3     p=/dev/rmt/7cbn  s=QUANTUM:DLT7000:TNA48S0267  l=1
4     p=/dev/rmt/19cbn s=QUANTUM:DLT8000:PKB02P0989  l=1 i=10200E09E6000030C36
5     p=/dev/rmt/20cbn s=QUANTUM:DLT8000:PKB02P0841  l=2 i=10200E09E6000030DC5

On AIX:

# bptpcinfo -t /dev -o -

Sample output:

devid [p=devpath]     [s=sn]  [n=npid]      [l=lun] [w=wwpn] [i=iddesc]
0 p=/dev/rmt0.1 s=STK:L20:LLC02203684           l=1
1 p=/dev/rmt5.1 s=QUANTUM:DLT8000:CXA49P1113    l=1  i=10200E09E6000034A57
2 p=/dev/rmt6.1 s=QUANTUM:DLT8000:PXB13P4180    l=2  i=10200E09E600004B70B
3 p=/dev/rmt7.1 s=STK:9840:331002059900         l=4  i=103500104F0004817E5
4 p=/dev/rmt9.1 s=QUANTUM:DLT8000:PXB33P0850    l=9  i=1036005013000B0526942333350
5 p=/dev/rmt10.1 s=QUANTUM:DLT8000:CX949P1208   l=10 i=1036005013000B0526939343950

Example 4 - Create a 3pc.conf file that describes all devices on the SAN, and send the output to an alternate file:

# bptpcinfo -a -o /usr/openv/volmgr/database/3pc_alt1.conf

NOTES

Note the following items when you use the bptpcinfo command:

  • Run the bptpcinfo command when no backups are in progress. If a backup operation uses or reserves a device, bptpcinfo may be unable to obtain information on it. It omits such a device from the output.

  • If you do not want to overwrite the existing 3pc.conf file, include the -o option and specify the wanted location.

  • If you have a host that runs Veritas SANPoint Control, do the following: Use the bpSALinfo command to add the worldwide name and LUN values for each device in the 3pc.conf file. If you do not have SANPoint Control, you must edit the new entries in the 3pc.conf file. To edit, manually add the worldwide name WWPN) and LUNs for each device.

    For more about SAN Configuration, see the NetBackup Snapshot Client Administrator's Guide.

FILES

/usr/openv/volmgr/database/3pc.conf