Veritas InfoScale™ Operations Manager 7.3.1 Add-ons User's Guide
- Section I. VCS Utilities Add-on 7.3.1
- Section II. Distribution Manager Add-on 7.3.1
- Section III. Fabric Insight Add-on 7.3.1
- Section IV. Patch Installer Add-on 7.3.1
- Introduction to Patch Installer Add-on
- Using Patch Installer Add-on
- Section V. Storage Insight Add-on 7.3.1
- Performing the deep discovery of enclosures
- About Storage Insight Add-on
- Adding HITACHI storage enclosures for deep discovery
- Editing the deep discovery configuration for an enclosure
- Monitoring the usage of thin pools
- Monitoring storage array metering data
- Managing LUN classifications
- Appendix A. Enclosure configuration prerequisites
- HITACHI enclosure configuration prerequisites
- EMC Symmetrix storage array configuration prerequisites
- Device setup requirements for EMC Symmetrix arrays
- IBM XIV enclosure configuration prerequisites
- NetApp storage enclosure configuration prerequisites
- EMC CLARiiON storage enclosures configuration prerequisites
- Hewlett-Packard Enterprise Virtual Array (HP EVA) configuration prerequisites
- IBM System Storage DS enclosure configuration prerequisites
- IBM SVC enclosure configuration prerequisites
- EMC Celerra enclosure configuration prerequisites
- EMC VNX storage enclosure configuration prerequisites
- EMC VPLEX storage enclosure configuration prerequisites
- Appendix B. Commands used by Management Server for deep discovery of enclosures
- Performing the deep discovery of enclosures
- Section VI. Storage Insight SDK Add-on 7.3.1
- Overview of Storage Insight SDK Add-on 7.3.1
- Managing Veritas InfoScale Operations Manager Storage Insight plug-ins
- About creating Storage Insight plug-in
- About discovery script
- About the enclosure discovery command output
- Creating a Storage Insight plug-in
- Editing a Storage Insight plug-in
- Testing a Storage Insight plug-in
- About creating Storage Insight plug-in
- Section VII. Storage Provisioning and Enclosure Migration Add-on 7.3.1
- Provisioning storage
- Creating a storage template using VxFS file systems
- Migrating volumes
- Provisioning storage
- Section VIII. Veritas HA Plug-in for VMware vSphere Web Client
- Introduction to Veritas HA Plug-in for vSphere Web Client
- Installation and uninstallation of Veritas HA Plug-in for vSphere Web Client
- Configurations for Veritas HA Plug-in for vSphere Web Client
- Section IX. Application Migration Add-on
- Introduction to Application Migration Add-on
- Creating and managing an application migration plan
- Understanding application migration operations
Create Storage Template - File system advanced panel options
Use this wizard panel to view or update the storage template file system advanced fields when you create or update the storage template. These parameters apply to running the mount and vxtunefs commands.
Note:
When you create a storage template based on Veritas File System (VxFS), you can set all the parameters. However, some of these parameters are not supported on certain platforms.
Table: Create Storage Template - Performance Tunables Tab
Field | Description |
---|---|
Enter the size of the intent log in the multiples of size byte. | |
Select an option to control the timing of flushing the VxFS intent log and other metadata to disk. This affects when operations are guaranteed persistent after a system failure. | |
Select the required mount I/O feature. | |
Select the required option. This implements an algorithm that allows read ahead to detect more elaborate patterns (such as increasing or decreasing read offsets, or multithreaded file accesses) in addition to simple sequential reads. | |
Enter the size of the allocation unit. | |
Enter a value for the initial extent. | |
Enter the maximum size of an extent. | |
Select the required option. For a file managed by a Hierarchical Storage Management (HSM) application, this option preallocates disk blocks before data is migrated back into the file system. | |
Enter a value for the maximum disk queue that is generated by a single file. | |
Enter a value to lower the number of dirty pages per file that the file system generates before writing them to disk. |
Table: File Change Log Tunables Tab
Field | Description |
---|---|
Enter a value for the VxFS File Change Log (FCL) to keep records in the log. | |
Enter the maximum amount of space that can be allocated to the VxFS File Change Log. | |
Enter the time interval in seconds within which subsequent opens of a file do not produce an additional FCL record. | |
Enter the time, in seconds, that must elapse before the VxFS File Change Log records a data overwrite, data extending write, or data truncate for a file. |
Table: Other Options Tab
Field | Description |
---|---|
Select an option. This lets the file system to be mounted explicitly. | |
Enter the preferred read request size. | |
Enter the number of parallel read requests of size read_pref_io that can be outstanding at one time. | |
Enter the preferred write request size. | |
Enter the number of parallel write requests of size write_pref_io that can be outstanding at one time. | |
Enter the maximum number of inodes to place on an inode aging list. | |
Enter the minimum size to qualify a deleted inode for inode aging. | |
Select an option to make the file system is large files capable. |