Veritas NetBackup™ 命令参考指南

Last Published:
Product(s): NetBackup (8.2)
  1. 介绍
    1.  
      关于 NetBackup 命令
    2.  
      浏览多个菜单级别
    3.  
      NetBackup 命令约定
    4.  
      NetBackup 介质管理器命令说明
    5.  
      IPv6 更新
  2. 附录 A. NetBackup 命令
    1.  
      acsd
    2.  
      add_media_server_on_clients
    3.  
      backupdbtrace
    4.  
      backuptrace
    5.  
      bmrc
    6.  
      bmrconfig
    7.  
      bmrepadm
    8.  
      bmrprep
    9.  
      bmrs
    10.  
      bmrsrtadm
    11.  
      bp
    12.  
      bparchive
    13.  
      bpbackup
    14.  
      bpbackupdb
    15.  
      bpcatarc
    16.  
      bpcatlist
    17.  
      bpcatres
    18.  
      bpcatrm
    19.  
      bpcd
    20.  
      bpchangeprimary
    21.  
      bpclient
    22.  
      bpclimagelist
    23.  
      bpclntcmd
    24.  
      bpclusterutil
    25.  
      bpcompatd
    26.  
      bpconfig
    27.  
      bpdbjobs
    28.  
      bpdbm
    29.  
      bpdgclone
    30.  
      bpdown
    31.  
      bpduplicate
    32.  
      bperror
    33.  
      bpexpdate
    34.  
      bpfis
    35.  
      bpflist
    36.  
      bpgetconfig
    37.  
      bpgetdebuglog
    38.  
      bpimage
    39.  
      bpimagelist
    40.  
      bpimmedia
    41.  
      bpimport
    42.  
      bpinst
    43.  
      bpkeyfile
    44.  
      bpkeyutil
    45.  
      bplabel
    46.  
      bplist
    47.  
      bpmedia
    48.  
      bpmedialist
    49.  
      bpminlicense
    50.  
      bpnbat
    51.  
      bpnbaz
    52.  
      bppficorr
    53.  
      bpplcatdrinfo
    54.  
      bpplclients
    55.  
      bppldelete
    56.  
      bpplinclude
    57.  
      bpplinfo
    58.  
      bppllist
    59.  
      bpplsched
    60.  
      bpplschedrep
    61.  
      bpplschedwin
    62.  
      bppolicynew
    63.  
      bpps
    64.  
      bprd
    65.  
      bprecover
    66.  
      bprestore
    67.  
      bpretlevel
    68.  
      bpschedule
    69.  
      bpschedulerep
    70.  
      bpsetconfig
    71.  
      bpstsinfo
    72.  
      bpstuadd
    73.  
      bpstudel
    74.  
      bpstulist
    75.  
      bpsturep
    76.  
      bptestbpcd
    77.  
      bptestnetconn
    78.  
      bptpcinfo
    79.  
      bpup
    80.  
      bpverify
    81.  
      cat_convert
    82.  
      cat_export
    83.  
      cat_import
    84.  
      configureCertsForPlugins
    85.  
      configureMQ
    86.  
      configurePorts
    87.  
      configureWebServerCerts
    88.  
      create_nbdb
    89.  
      csconfig cldinstance
    90.  
      csconfig cldprovider
    91.  
      csconfig meter
    92.  
      csconfig throttle
    93.  
      csconfig reinitialize
    94.  
      duplicatetrace
    95.  
      importtrace
    96.  
      jbpSA
    97.  
      jnbSA
    98.  
      ltid
    99.  
      manageClientCerts
    100.  
      mklogdir
    101.  
      nbauditreport
    102.  
      nbcatsync
    103.  
      NBCC
    104.  
      NBCCR
    105.  
      nbcertcmd
    106.  
      nbcertupdater
    107.  
      nbcldutil
    108.  
      nbcloudrestore
    109.  
      nbcomponentupdate
    110.  
      nbcplogs
    111.  
      nbdb_admin
    112.  
      nbdb_backup
    113.  
      nbdb_move
    114.  
      nbdb_ping
    115.  
      nbdb_restore
    116.  
      nbdb_unload
    117.  
      nbdbms_start_server
    118.  
      nbdbms_start_stop
    119.  
      nbdc
    120.  
      nbdecommission
    121.  
      nbdelete
    122.  
      nbdeployutil
    123.  
      nbdevconfig
    124.  
      nbdevquery
    125.  
      nbdiscover
    126.  
      nbdna
    127.  
      nbemm
    128.  
      nbemmcmd
    129.  
      nbfindfile
    130.  
      nbfirescan
    131.  
      nbftadm
    132.  
      nbftconfig
    133.  
      nbgetconfig
    134.  
      nbhba
    135.  
      nbholdutil
    136.  
      nbhostidentity
    137.  
      nbhostmgmt
    138.  
      nbhypervtool
    139.  
      nbimageshare
    140.  
      nbinstallcmd
    141.  
      nbjm
    142.  
      nbkmsutil
    143.  
      nboraadm
    144.  
      nborair
    145.  
      nbpem
    146.  
      nbpemreq
    147.  
      nbperfchk
    148.  
      nbplupgrade
    149.  
      nbrb
    150.  
      nbrbutil
    151.  
      nbregopsc
    152.  
      nbreplicate
    153.  
      nbrepo
    154.  
      nbrestorevm
    155.  
      nbseccmd
    156.  
      nbsetconfig
    157.  
      nbsnapimport
    158.  
      nbsnapreplicate
    159.  
      nbsqladm
    160.  
      nbstl
    161.  
      nbstlutil
    162.  
      nbstop
    163.  
      nbsu
    164.  
      nbsvrgrp
    165.  
      resilient_clients
    166.  
      restoretrace
    167.  
      stopltid
    168.  
      tl4d
    169.  
      tl8d
    170.  
      tl8cd
    171.  
      tldd
    172.  
      tldcd
    173.  
      tlhd
    174.  
      tlhcd
    175.  
      tlmd
    176.  
      tpautoconf
    177.  
      tpclean
    178.  
      tpconfig
    179.  
      tpext
    180.  
      tpreq
    181.  
      tpunmount
    182.  
      verifytrace
    183.  
      vltadm
    184.  
      vltcontainers
    185.  
      vlteject
    186.  
      vltinject
    187.  
      vltoffsitemedia
    188.  
      vltopmenu
    189.  
      vltrun
    190.  
      vmadd
    191.  
      vmchange
    192.  
      vmcheckxxx
    193.  
      vmd
    194.  
      vmdelete
    195.  
      vmoprcmd
    196.  
      vmphyinv
    197.  
      vmpool
    198.  
      vmquery
    199.  
      vmrule
    200.  
      vmupdate
    201.  
      vnetd
    202.  
      vssat
    203.  
      vwcp_manage
    204.  
      vxlogcfg
    205.  
      vxlogmgr
    206.  
      vxlogview
    207.  
      W2KOption

名称

vltoffsitemedia — 列出一组介质的场外参数值,或者更改一个介质的场外参数值

大纲

vltoffsitemedia -list [-W] [-vault vault_name] [-voldbhost host_name]

vltoffsitemedia -change -m media_id [-voldbhost host_name] [-d media_description] [-vltname vault_name] [-vltsent date][-vltreturn date] [-vltslot slot_no] [-vltcid container_id] [-vltsession session_id]

vltoffsitemedia -version

 

在 UNIX 系统上,此命令的目录路径为 /usr/openv/netbackup/bin/

在 Windows 系统中,此命令的目录路径为 install_path\NetBackup\bin\

描述

用户可以使用 vltoffsitemedia 命令更改给定介质的特定保管库参数。使用此命令,用户可以用单个命令更改一个或多个参数。用户可以使用该命令来查看特定 EMM 服务器或保管库的所有介质的各个保管库参数。

如果创建以下具有公共写入权限的目录,则 vltoffsitemedia 将在此目录下创建每日调试日志:

对于 UNIX:/usr/openv/netbackup/logs/vault

对于 Windows:install_path\netbackup\logs\vault

该日志称为 log.DDMMYY(其中 DDMMYY 为当前日期)。然后就可使用此文件进行故障排除。

由于以 root 身份并非可以运行所有写入该文件的可执行文件,因此需要公共写入权限。

选项

-change

更改指定卷的属性。

-d media_description

指定该卷的说明。

要将 NetBackup 配置为在卷返回机械手时自动清除介质描述字段,请在 EMM 中设置 VAULT_CLEAR_MEDIA_DESC 参数。

-list

为本地 EMM 数据库中的介质列出场外参数。要将列表限制为仅包含本地 EMM 数据库的特定保管库,请在命令中包括 -vault 选项。要为特定 EMM 数据库中的介质列出场外参数,请在命令中包括 -voldbhost 选项。

-m media_id

要更改其保管库参数的卷的介质 ID。

-vault vault_name

指定要列出其所有介质 ID 及其特定于保管库的参数的保管库的名称。

-version

显示 vltoffsitemedia 版本,然后退出。

-vltcid container_id

指定存储卷的容器。container_id(一个字符串,最多包含 29 个字母数字字符,不含空格)用于指定该卷的新容器。必须指定现有的容器 ID。在为一个 EMM 服务器中的介质分配的容器中,不能包含另一个 EMM 服务器中的介质。可以使用 -m 选项来指定卷的介质 ID。

-vltname vault_name

指定为弹出卷的机械手配置的逻辑保管库的名称。

-vltreturn date

指定请求从保管库供应商返回介质的日期和时间。对于目录库备份卷,此日期是请求从保管库供应商返回该介质的日期。

NetBackup 命令所需要的日期和时间值格式因区域设置的不同而不同。/usr/openv/msg/.conf 文件 (UNIX) 和 install_path\VERITAS\msg\LC.CONF 文件 (Windows) 包含诸如每个所支持的区域设置的日期时间格式等信息。这些文件包含有关如何添加或修改所支持的区域设置和格式列表的具体说明。

有关更多信息,请参见 NetBackup 管理指南,第 II 卷中的“关于指定 NetBackup 安装的区域设置”主题。

-vltsent date

指定将介质发送到场外保管库的日期和时间。

NetBackup 命令所需要的日期和时间值格式因区域设置的不同而不同。/usr/openv/msg/.conf 文件 (UNIX) 和 install_path\VERITAS\msg\LC.CONF 文件 (Windows) 包含诸如每个所支持的区域设置的日期时间格式等信息。这些文件包含有关如何添加或修改所支持的区域设置和格式列表的具体说明。

有关更多信息,请参见 NetBackup 管理指南,第 II 卷中的“关于指定 NetBackup 安装的区域设置”主题。

mm/dd/yyyy [hh[:mm[:ss]]]
-vltsession session_id

指定弹出该介质的保管库会话的标识符。

-vltslot slot_no

为该卷占用的插槽指定保管库供应商的插槽号。

-voldbhost host_name

指定 EMM 服务器的名称。

-W

指定介质场外参数的可分析输出格式。对于容器,输出包括容器说明的长度、容器说明和容器 ID。输出标头行是一行以空格分隔的列标签;输出数据行是以空格分隔的字段。

示例

示例 1 - 更改 ID 为 BYQ 的介质的保管库名称和保管库发送日期。

vltoffsitemedia -change -m BYQ -vltname THISTLE -vltsent 08/01/2012 
12:22:00

示例 2 - 将 ID 为 000012 的介质的保管库插槽号更改为 100。

vltoffsitemedia -change -m 000012 -vltslot 100

示例 3 - 清除介质的特定于保管库的字段。

vltoffsitemedia -change -m 000012 -vltname "" -vltsession 0 -vltslot 
0 -vltsent 0 -vltreturn 0

或:

vltoffsitemedia -change -m 000012 -vltname - -vltsession 0 -vltslot 
0 -vltsent 00/00/00 -vltreturn 00/00/00

示例 4 - 清除卷 ABC123 的容器 ID 和介质描述。

vltoffsitemedia -change -m ABC123 -vltcid - -d ""

或:

vltoffsitemedia -change -m ABC123 -vltcid "" -d ""

vltoffsitemedia 命令使用介质管理器命令来查询或更新 EMM 数据库。

如果 vltoffsitemedia 命令失败,请在以下目录的调试日志中查看有关失败的实际介质管理器命令的详细信息。

UNIX 系统:usr/openv/netbackup/logs/vault

Windows 系统:install_path\netbackup\logs\vault

有关介质管理器命令返回的状态码的更多信息,请参见 NetBackup 状态码参考指南

返回值

保管库退出时的状态码可能会大于 255。这样的状态码称为扩展退出状态码。在这种情况下,返回到系统的退出状态为 252,而实际退出状态将按如下格式写入 stderr:EXIT status = exit status

《NetBackup 状态码参考指南》和 NetBackup 故障排除工具向导中介绍了扩展的退出状态值。