InfoScale™ 9.0 Storage Foundation for Oracle® RAC Administrator's Guide - Linux
- Section I. SF Oracle RAC concepts and administration
- Overview of Storage Foundation for Oracle RAC
- Component products and processes of SF Oracle RAC
- Communication infrastructure
- Cluster interconnect communication channel
- Cluster Volume Manager (CVM)
- About Flexible Storage Sharing
- Cluster File System (CFS)
- Cluster Server (VCS)
- Oracle RAC components
- Oracle Disk Manager
- RAC extensions
- About Virtual Business Services
- Administering SF Oracle RAC and its components
- Administering SF Oracle RAC
- Starting or stopping SF Oracle RAC on each node
- Administering VCS
- Administering I/O fencing
- About the vxfentsthdw utility
- About the vxfenadm utility
- About the vxfenswap utility
- Administering the CP server
- Administering CFS
- Administering CVM
- Changing the CVM master manually
- Administering Flexible Storage Sharing
- Backing up and restoring disk group configuration data
- Administering SF Oracle RAC global clusters
- Administering SF Oracle RAC
- Overview of Storage Foundation for Oracle RAC
- Section II. Performance and troubleshooting
- Troubleshooting SF Oracle RAC
- About troubleshooting SF Oracle RAC
- Troubleshooting I/O fencing
- Troubleshooting CP server
- Troubleshooting server-based fencing on the SF Oracle RAC cluster nodes
- Issues during online migration of coordination points
- Troubleshooting Cluster Volume Manager in SF Oracle RAC clusters
- Troubleshooting CFS
- Troubleshooting interconnects
- Troubleshooting Oracle
- Troubleshooting ODM in SF Oracle RAC clusters
- Prevention and recovery strategies
- Tunable parameters
- Troubleshooting SF Oracle RAC
- Section III. Reference
Clearing preexisting split-brain condition
Review the information on how the VxFEN driver checks for preexisting split-brain condition.
See Fencing startup reports preexisting split-brain.
See About the vxfenclearpre utility.
Table: Recommened solution to clear pre-existing split-brain condition describes how to resolve a preexisting split-brain condition depending on the scenario you have encountered:
Table: Recommened solution to clear pre-existing split-brain condition
Scenario | Solution |
---|---|
Actual potential split-brain condition - system 2 is up and system 1 is ejected |
|
Apparent potential split-brain condition - system 2 is down and system 1 is ejected (Disk-based fencing is configured) |
|
Apparent potential split-brain condition - system 2 is down and system 1 is ejected (Server-based fencing is configured) |
|