Array/LUN performance Data Collection
The following array families are supported for block storage LUN performance and port performance data collection.
See Array/LUN performance notes.
Table: Array Family
Array Family | Rd/Wrte IO/sec | Total IO/sec | Rd/WrteMB / sec | Rd/Wrte Cache Hits/sec | Rd/Wrte Respond(ms) | Total Respond(ms) |
---|---|---|---|---|---|---|
Dell Compellent | X | X | X | X | -- | -- |
EMC VNX | X | Calc. | X | X | X | Calc. |
EMC Symmetrix | X | X | X | X | -- | -- |
EMC XtremIO | Calc. | Calc. | Calc. | -- | X | X |
HDS Tuning Manager | X | Calc. | X | X | X | X |
HP 3PAR | X | X | X | X | X | X |
IBM SVC | X | X | X | -- | -- | -- |
IBM XIV | X | X | X | X | X | X |
NetApp ONTAP 7-Mode (Block only) | X | Calc. | X | -- | -- | Avg Latency |
Pure Storage FlashArray | X | Calc. | X | -- | X | Calc. |
The following notes apply to array families are supported for block storage LUN performance and port performance data collection.
Table: Array families supporting block storage LUN performance and port performance data collection.
Array Family | Notes |
---|---|
EMC VNX | The minimum FLARE OS version required to capture response times is 04.30.000.5.524 A11. Note that VNX (Block) will have completely different FLARE releases and all support the collection of the counter fields needed for capturing response time, starting with FLARE version 05.31.000.5.006 A01. Enable statistics logging on the VNX system. |
EMC XtremIO | For EMC XtremIO, the values obtained are averages over the time interval. The Read/Write/Total IOs and the Read/Write MBs are multiplied by the time interval and persisted. |
HDS Tuning Manager | For Hitachi arrays: To collect performance data from Hitachi Tuning Manager, the Data Collector must be installed on the same server as Tuning Manager. And, a single Data Collector policy must be used to collect both the capacity data from the Device Manager server and the performance data from the Tuning Manager server. |
NetApp ONTAP 7-Mode (Block only) | For NetApp ONTAP 7-Mode (Block only): Total response time is the average latency (ms) for all LUN read and write operations. Performance data is collected for both iSCSI LUNs and FC LUNs. |