APTARE IT Analytics Data Collector Installation Guide for Backup Manager
- Introduction
- Pre-Installation setup for Commvault Simpana
- Open TCP/IP access to the Commvault database
- Set up a read-only user in the CommServe server
- Pre-Installation setup for Cohesity DataProtect
- Pre-Installation setup for EMC Avamar
- Import EMC Avamar server information
- Pre-Installation setup for EMC Data Domain backup
- Pre-Installation setup for EMC NetWorker
- Architecture overview (EMC NetWorker)
- Pre-Installation setup for Dell EMC NetWorker backup & Recovery
- Pre-Installation setup for generic backup
- CSV format specification
- Pre-Installation setup for HP Data Protector
- Architecture overview (HP Data Protector)
- Configure the Data Collector server in Cell Manager (HP Data Protector)
- Pre-Installation setup for IBM Spectrum Protect (TSM)
- Architecture overview (IBM Spectrum Protect -TSM)
- Import IBM Spectrum Protect (TSM) information
- Pre-Installation setup for NAKIVO Backup & Replication
- Pre-Installation setup for Veritas Backup Exec
- Pre-Installation setup for Veritas NetBackup
- Prerequisites to use SSH and WMI (Veritas NetBackup)
- Prerequisites for NetBackup collection over SSH (Kerberos option)
- Veritas NetBackup 8.1 (or later) requirements for centralized collection
- Configuring file analytics in NetBackup Data Collector policy
- Pre-Installation setup for Veritas SaaS backup
- Pre-Installation setup for Oracle Recovery Manager (RMAN)
- Pre-Installation setup for Rubrik Cloud Data Management
- Pre-Installation setup for Veeam Backup & Replication
- Discovery policies for Veritas NetBackup
- About Discovery types
- About SNMP probes
- Installing the Data Collector software
- Validate data collection
- Manually start the Data Collector
- Uninstall the Data Collector
- Appendix A. Load historic events
- Load Veritas NetBackup events
- Appendix B. Firewall configuration: Default ports
Using the CLI check install utility
This legacy utility performs both the Test Connection function and On-Demand data collection run from a command line interface launched from the Data Collector server.
Note:
APTARE IT Analytics does not recommend using the CLI Checkinstall utility for any Data Collector subsystem vendor which supports On-Demand runs.
The following directions assume that the Data Collector files have been installed in their default location:
Windows (C:\Program Files\Aptare) or Linux (/opt/aptare).
If you have installed the files in a different directory, make the necessary path translations in the following instructions.
Note:
Some of the following commands can take up to several hours, depending on the size of your enterprise.
To run Checkinstall
- Open a session on the Data Collector server.
Windows: Open a command prompt window.
Linux: Open a telnet session logged in as root to the Data Collector Server.
- Change to the directory where you'll run the validation script.
Windows: At the command prompt, type:
cd C:\Program Files\Aptare\mbs\bin <enter>
Linux: In the telnet session, type:
cd /opt/aptare/mbs/bin <enter>
- Execute the validation script.
Windows: At the command prompt, type: checkinstall.bat <enter>
Linux: In the telnet session. type: ./checkinstall.sh <enter>
The checkinstall utility performs a high-level check of the installation, including a check for the domain, host group and URL, Data Collector policy and database connectivity. This utility will fail if a Data Collector policy has not been configured in the Portal. For a component check, specifically for Host Resources, run the hostresourcedetail.sh|batutility.
Checkinstall includes an option to run a probe for one or more specific devices. Note that certain Data Collectors will not allow individual selection of devices. Typically these are collectors that allow the entry of multiple server addresses or ranges of addresses in a single text box.
These collectors include: Cisco Switch, EMC CLARiiON, EMC Data Domain, EMC VNX arrays, HP 3PAR, IBM mid-range arrays, IBM XIV arrays and VMware.
Data Collectors that probe all devices that are attached to a management server also do not allow individual selection of devices: EMC Symmetric, File Analytics, Hitachi arrays and IBM VIO.
- If the output in the previous steps contains the word FAILED, then contact Support and have the following files ready for review: /opt/aptare/mbs/logs/validation/
C:\Program Files\Aptare\mbs\logs\validation\