Veritas NetBackup™ Flex Scale Release Notes
- Getting help
- Features, enhancements, and changes
- What's new in this release
- What's new in this release
- Limitations
- Known issues
- Cluster configuration issues
- Disaster recovery issues
- Miscellaneous issues
- NetBackup issues
- Networking issues
- Node and disk management issues
- Security and authentication issues
- Upgrade issues
- UI issues
- Cluster configuration issues
- Fixed issues
Add node fails during precheck when a secondary data network is configured over the management interface and the Automatic tab is used for providing input IPs for the new node to be added for the secondary data network over management interface
If the management network (eth1 or eth1.<VLANID>) is configured to use a DNS name server, then during the add node operation, the Automatic tab is enabled to provide input for the secondary data network IPs for the management interface. If the Automatic tab is used to provide inputs for the required secondary data network IPs for the new node, then during IP/FQDN validation, the FQDN resolution for management network IPs fail. This happens when the data DNS name server is different from the management DNS name server and the input IPs provided for the management network do not exist in the data DNS.
(IA-47639)
Workaround:
Use the Custom tab for providing input IP/FQDN for secondary data network on management interface during add node operation.