Veritas InfoScale™ 7.3.1 Troubleshooting Guide - Solaris
- Introduction
- Section I. Troubleshooting Veritas File System
- Section II. Troubleshooting Veritas Volume Manager
- Recovering from hardware failure
- Failures on RAID-5 volumes
- Recovery from failure of a DCO volume
- Recovering from instant snapshot failure
- Recovering from failed vxresize operation
- Recovering from boot disk failure
- Hot-relocation and boot disk failure
- Recovery from boot failure
- Repair of root or /usr file systems on mirrored volumes
- Replacement of boot disks
- Recovery by reinstallation
- Managing commands, tasks, and transactions
- Backing up and restoring disk group configurations
- Troubleshooting issues with importing disk groups
- Recovering from CDS errors
- Logging and error messages
- Troubleshooting Veritas Volume Replicator
- Recovery from configuration errors
- Errors during an RLINK attach
- Errors during modification of an RVG
- Recovery on the Primary or Secondary
- Recovering from Primary data volume error
- Primary SRL volume error cleanup and restart
- Primary SRL header error cleanup and recovery
- Secondary data volume error cleanup and recovery
- Troubleshooting issues in cloud deployments
- Recovering from hardware failure
- Section III. Troubleshooting Dynamic Multi-Pathing
- Section IV. Troubleshooting Storage Foundation Cluster File System High Availability
- Troubleshooting Storage Foundation Cluster File System High Availability
- Troubleshooting CFS
- Troubleshooting fenced configurations
- Troubleshooting Cluster Volume Manager in Veritas InfoScale products clusters
- Troubleshooting Storage Foundation Cluster File System High Availability
- Section V. Troubleshooting Cluster Server
- Troubleshooting and recovery for VCS
- VCS message logging
- Gathering VCS information for support analysis
- Troubleshooting the VCS engine
- Troubleshooting Low Latency Transport (LLT)
- Troubleshooting Group Membership Services/Atomic Broadcast (GAB)
- Troubleshooting VCS startup
- Troubleshooting service groups
- Troubleshooting resources
- Troubleshooting I/O fencing
- System panics to prevent potential data corruption
- Fencing startup reports preexisting split-brain
- Troubleshooting CP server
- Troubleshooting server-based fencing on the Veritas InfoScale products cluster nodes
- Issues during online migration of coordination points
- Troubleshooting notification
- Troubleshooting and recovery for global clusters
- Troubleshooting licensing
- Licensing error messages
- VCS message logging
- Troubleshooting and recovery for VCS
- Section VI. Troubleshooting SFDB
Replacement of boot disks
Data that is not critical for booting the system is only accessed by VxVM after the system is fully operational, so it does not have to be located in specific areas. VxVM can find it. However, boot-critical data must be placed in specific areas on the bootable disks for the boot process to find it.
On some systems, the controller-specific actions performed by the disk controller in the process and the system BIOS constrain the location of this critical data.
If a boot disk fails, one of the following procedures can be used to correct the problem:
If the errors are transient or correctable, re-use the same disk. This is known as re-adding a disk. In some cases, reformatting a failed disk or performing a surface analysis to rebuild the alternate-sector mappings are sufficient to make a disk usable for re-addition.
If the disk has failed completely, replace it.