Please enter search query.
Search <book_title>...
Veritas InfoScale™ 7.3.1 Troubleshooting Guide - Solaris
Last Published:
2018-08-22
Product(s):
InfoScale & Storage Foundation (7.3.1)
Platform: Solaris
- Introduction
- Section I. Troubleshooting Veritas File System
- Section II. Troubleshooting Veritas Volume Manager
- Recovering from hardware failure
- Failures on RAID-5 volumes
- Recovery from failure of a DCO volume
- Recovering from instant snapshot failure
- Recovering from failed vxresize operation
- Recovering from boot disk failure
- Hot-relocation and boot disk failure
- Recovery from boot failure
- Repair of root or /usr file systems on mirrored volumes
- Replacement of boot disks
- Recovery by reinstallation
- Managing commands, tasks, and transactions
- Backing up and restoring disk group configurations
- Troubleshooting issues with importing disk groups
- Recovering from CDS errors
- Logging and error messages
- Troubleshooting Veritas Volume Replicator
- Recovery from configuration errors
- Errors during an RLINK attach
- Errors during modification of an RVG
- Recovery on the Primary or Secondary
- Recovering from Primary data volume error
- Primary SRL volume error cleanup and restart
- Primary SRL header error cleanup and recovery
- Secondary data volume error cleanup and recovery
- Troubleshooting issues in cloud deployments
- Recovering from hardware failure
- Section III. Troubleshooting Dynamic Multi-Pathing
- Section IV. Troubleshooting Storage Foundation Cluster File System High Availability
- Troubleshooting Storage Foundation Cluster File System High Availability
- Troubleshooting CFS
- Troubleshooting fenced configurations
- Troubleshooting Cluster Volume Manager in Veritas InfoScale products clusters
- Troubleshooting Storage Foundation Cluster File System High Availability
- Section V. Troubleshooting Cluster Server
- Troubleshooting and recovery for VCS
- VCS message logging
- Gathering VCS information for support analysis
- Troubleshooting the VCS engine
- Troubleshooting Low Latency Transport (LLT)
- Troubleshooting Group Membership Services/Atomic Broadcast (GAB)
- Troubleshooting VCS startup
- Troubleshooting service groups
- Troubleshooting resources
- Troubleshooting I/O fencing
- System panics to prevent potential data corruption
- Fencing startup reports preexisting split-brain
- Troubleshooting CP server
- Troubleshooting server-based fencing on the Veritas InfoScale products cluster nodes
- Issues during online migration of coordination points
- Troubleshooting notification
- Troubleshooting and recovery for global clusters
- Troubleshooting licensing
- Licensing error messages
- VCS message logging
- Troubleshooting and recovery for VCS
- Section VI. Troubleshooting SFDB
Node is unable to join cluster while another node is being ejected
A cluster that is currently fencing out (ejecting) a node from the cluster prevents a new node from joining the cluster until the fencing operation is completed. The following are example messages that appear on the console for the new node:
...VxFEN ERROR V-11-1-25 ... Unable to join running cluster since cluster is currently fencing a node out of the cluster.
If you see these messages when the new node is booting, the vxfen startup script on the node makes up to five attempts to join the cluster.
To manually join the node to the cluster when I/O fencing attempts fail
- If the vxfen script fails in the attempts to allow the node to join the cluster, restart vxfen driver with the command:
# svcadm disable -t vxfen # svcadm enable vxfen
If the command fails, restart the new node.