- About Folder Sync
- Requirements for Folder Sync
- Preparing the service and admin accounts for Folder Sync
- Installing or upgrading Folder Sync
- Configuring the Folder Sync task
- Running and scheduling Folder Sync synchronizations
- Performing a "Run Now" Folder Sync synchronization
- Monitoring and managing Folder Sync
- Viewing the All Mailboxes table
- Viewing the Folder Sync job list
- Viewing the Folder Sync mailbox report
- Viewing the Folder Sync status report
- Troubleshooting Folder Sync
Troubleshooting occasional time-outs of the Folder Sync service
If the Folder Sync host server is slightly underpowered you may experience occasional time-outs of the ArchiveTools Folder Sync service.
An error such as the following may be received:
Windows could not start the ArchiveTools Folder Sync service on Local Computer. Error 1053: The service did not respond to the start or control request in a timely fashion.
To help to avoid a time out of the service in this situation, you can set a Windows registry value on the host server as follows.
To troubleshoot occasional time-outs of the Folder Sync service
- Start the Windows registry editor on the Folder Sync host server.
- Locate the following registry subkey:
HKEY_LOCAL_MACHINE \SYSTEM \CurrentControlSet \Control
- Under this subkey, edit or create the following DWORD value: ServicesPipeTimeout.
Give ServicesPipeTimeout a decimal value of 180000.
- Exit from the registry editor.
- You must restart the host server to apply this change.