Please enter search query.
Search <book_title>...
Veritas Access Release Notes
Last Published:
2023-01-04
Product(s):
Access (7.4.2.400)
Platform: Linux
- Overview of Veritas Access
- Software limitations
- Flexible Storage Sharing limitations
- Limitations related to installation and upgrade
- Limitation related to replication
- Known issues
- Veritas Access known issues
- Admin issues
- CIFS issues
- FTP issues
- General issues
- GUI issues
- Installation and configuration issues
- Internationalization (I18N) issues
- Networking issues
- NFS issues
- ObjectAccess issues
- OpenStack issues
- Replication issues
- SmartIO issues
- Storage issues
- System issues
- Upgrade issues
- Veritas Data Deduplication issues
- Veritas Access known issues
- Getting help
After upgrading from version 7.4.2.301 to version 7.4.2.400, full discovery is not triggered automatically
Post-upgrade, some scripts are required to be executed sequentially, instead these run in parallel, leading to stale flags.
(IA-34907)
Workaround:
- Run the following command on the node where the management console is running:
- /opt/VRTSnas/pysnas/bin/isaconfig --post-upgrade
- Start full discovery:
/opt/VRTSnas/pysnas/bin/isagui_cluster_perf.py --full
Finished user discovery # echo $? 0
- Restart the GUI from the Veritas Access command-line interface:
system guidisable
system guienable