- Section I. Introduction to SFHA
- Section II. Configuration of SFHA
- Preparing to configure
- Preparing to configure SFHA clusters for data integrity
- About planning to configure I/O fencing
- Setting up the CP server
- Configuring the CP server manually
- Configuring CP server using response files
- Configuring SFHA
- Configuring Storage Foundation High Availability using the installer
- Configuring a secure cluster node by node
- Verifying and updating licenses on the system
- Configuring Storage Foundation High Availability using the installer
- Configuring SFHA clusters for data integrity
- Setting up disk-based I/O fencing using installer
- Setting up server-based I/O fencing using installer
- Manually configuring SFHA clusters for data integrity
- Setting up disk-based I/O fencing manually
- Setting up server-based I/O fencing manually
- Configuring server-based fencing on the SFHA cluster manually
- Setting up non-SCSI-3 fencing in virtual environments manually
- Setting up majority-based I/O fencing manually
- Performing an automated SFHA configuration using response files
- Performing an automated I/O fencing configuration using response files
- Section III. Upgrade of SFHA
- Planning to upgrade SFHA
- Preparing to upgrade SFHA
- Upgrading Storage Foundation and High Availability
- Performing a rolling upgrade of SFHA
- Performing a phased upgrade of SFHA
- About phased upgrade
- Performing a phased upgrade using the product installer
- Performing an automated SFHA upgrade using response files
- Upgrading SFHA using Boot Environment upgrade
- Performing post-upgrade tasks
- Post-upgrade tasks when VCS agents for VVR are configured
- Upgrading the Array Support Library
- About enabling LDAP authentication for clusters that run in secure mode
- Planning to upgrade SFHA
- Section IV. Post-installation tasks
- Section V. Adding and removing nodes
- Adding a node to SFHA clusters
- Adding the node to a cluster manually
- Adding a node using response files
- Configuring server-based fencing on the new node
- Removing a node from SFHA clusters
- Removing a node from a SFHA cluster
- Removing a node from a SFHA cluster
- Adding a node to SFHA clusters
- Section VI. Configuration and upgrade reference
- Appendix A. Installation scripts
- Appendix B. SFHA services and ports
- Appendix C. Configuration files
- Appendix D. Configuring the secure shell or the remote shell for communications
- Appendix E. Sample SFHA cluster setup diagrams for CP server-based I/O fencing
- Appendix F. Reconciling major/minor numbers for NFS shared disks
- Appendix G. Configuring LLT over UDP
- Using the UDP layer for LLT
- Manually configuring LLT over UDP using IPv4
- Using the UDP layer of IPv6 for LLT
- Manually configuring LLT over UDP using IPv6
Adding JBOD support for storage arrays for which there is not an ASL available
If an array is of type A/A-A, A/P or ALUA and a suitable ASL is not available, the array must be claimed as a JBOD of type A/P. This is to prevent path delays and I/O failures arising. As JBODs are assumed to be type A/A by default, you must create appropriate JBOD entries for such arrays.
To configure an A/A-A, A/P or ALUA array as a JBOD
- Stop all applications, such as databases, from accessing the VxVM volumes that are configured on the array, and unmount all VxFS file systems and Storage Checkpoints that are configured on the array.
- Add the array as a JBOD of type A/P:
# vxddladm addjbod vid=SUN pid=T300 policy=ap
- If you have not already done so, upgrade the Storage Foundation or VxVM software to 9.0. Device discovery is performed during the upgrade, and the array is claimed as a JBOD of appropriate type.
If you have already upgraded your system to 9.0, run the following command to perform device discovery:
# vxdctl enable
- Verify that the array has been added with the policy set to APdisk:
# vxddladm listjbod VID PID Opcode Page Code Page Offset SNO length Policy ============================================================ SUN T300 18 -1 36 12 APdisk
- Check that the correct devices are listed for the array:
# vxdisk list DEVICE TYPE DISK GROUP STATUS APdisk_0 auto:cdsdisk - - online invalid APdisk_1 auto:cdsdisk - - online invalid APdisk_2 auto:cdsdisk - - online invalid ...