InfoScale™ 9.0 Storage Foundation Cluster File System High Availability Configuration and Upgrade Guide - Solaris
- Section I. Introduction to SFCFSHA
- Introducing Storage Foundation Cluster File System High Availability
- Section II. Configuration of SFCFSHA
- Preparing to configure
- Preparing to configure SFCFSHA clusters for data integrity
- About planning to configure I/O fencing
- Setting up the CP server
- Configuring the CP server manually
- Configuring SFCFSHA
- Configuring a secure cluster node by node
- Verifying and updating licenses on the system
- Configuring SFCFSHA clusters for data integrity
- Setting up disk-based I/O fencing using installer
- Setting up server-based I/O fencing using installer
- Performing an automated SFCFSHA configuration using response files
- Performing an automated I/O fencing configuration using response files
- Configuring CP server using response files
- Manually configuring SFCFSHA clusters for data integrity
- Setting up disk-based I/O fencing manually
- Setting up server-based I/O fencing manually
- Configuring server-based fencing on the SFCFSHA cluster manually
- Setting up non-SCSI-3 fencing in virtual environments manually
- Setting up majority-based I/O fencing manually
- Section III. Upgrade of SFCFSHA
- Planning to upgrade SFCFSHA
- Preparing to upgrade SFCFSHA
- Performing a full upgrade of SFCFSHA using the installer
- Performing a rolling upgrade of SFCFSHA
- Performing a phased upgrade of SFCFSHA
- About phased upgrade
- Performing a phased upgrade using the product installer
- Performing an automated SFCFSHA upgrade using response files
- Upgrading Volume Replicator
- Upgrading VirtualStore
- Upgrading SFCFSHA using Boot Environment upgrade
- Performing post-upgrade tasks
- Planning to upgrade SFCFSHA
- Section IV. Post-configuration tasks
- Section V. Configuration of disaster recovery environments
- Section VI. Adding and removing nodes
- Adding a node to SFCFSHA clusters
- Adding the node to a cluster manually
- Setting up the node to run in secure mode
- Adding a node using response files
- Configuring server-based fencing on the new node
- Removing a node from SFCFSHA clusters
- Adding a node to SFCFSHA clusters
- Section VII. Configuration and Upgrade reference
- Appendix A. Installation scripts
- Appendix B. Configuration files
- Appendix C. Configuring the secure shell or the remote shell for communications
- Appendix D. High availability agent information
- Appendix E. Sample SFCFSHA cluster setup diagrams for CP server-based I/O fencing
- Appendix F. Reconciling major/minor numbers for NFS shared disks
- Appendix G. Configuring LLT over UDP
- Using the UDP layer for LLT
- Manually configuring LLT over UDP using IPv4
- Using the UDP layer of IPv6 for LLT
- Manually configuring LLT over UDP using IPv6
Configuring SNMP trap notification
You can choose to configure VCS to send event notifications to SNMP management consoles. You need to provide the SNMP management console name to be notified and message severity levels.
Note that you can also configure the notification after installation.
Refer to the Cluster Server Administrator's Guide for more information.
To configure the SNMP trap notification
- Review the required information to configure the SNMP notification feature of VCS.
- Specify whether you want to configure the SNMP notification.
If you skip this option and if you had installed a valid HA/DR license, the installer presents you with an option to configure this cluster as global cluster. If you did not install an HA/DR license, the installer proceeds to configure SFCFSHA based on the configuration details you provided.
- Provide information to configure SNMP trap notification.
Provide the following information:
Enter the SNMP trap daemon port.
Enter the SNMP trap daemon port: [b,q,?] (162)
Enter the SNMP console system name.
Enter the SNMP console system name: [b,q,?] sys5
Enter the minimum security level of messages to be sent to each console.
Enter the minimum severity of events for which SNMP traps should be sent to sys5 [I=Information, W=Warning, E=Error, S=SevereError]: [b,q,?] E
Add more SNMP consoles, if necessary.
If you want to add another SNMP console, enter y and provide the required information at the prompt.
Would you like to add another SNMP console? [y,n,q,b] (n) y Enter the SNMP console system name: [b,q,?] sys4 Enter the minimum severity of events for which SNMP traps should be sent to sys4 [I=Information, W=Warning, E=Error, S=SevereError]: [b,q,?] S
If you do not want to add, answer n.
Would you like to add another SNMP console? [y,n,q,b] (n)
- Verify and confirm the SNMP notification information.
SNMP Port: 162 Console: sys5 receives SNMP traps for Error or higher events Console: sys4 receives SNMP traps for SevereError or higher events Is this information correct? [y,n,q] (y)
More Information