Storage Foundation for Oracle® RAC 7.4.1 Administrator's Guide - Linux
- Section I. SF Oracle RAC concepts and administration
- Overview of Storage Foundation for Oracle RAC
- About Storage Foundation for Oracle RAC
- How SF Oracle RAC works (high-level perspective)
- Component products and processes of SF Oracle RAC
- Periodic health evaluation of SF Oracle RAC clusters
- About Virtual Business Services
- About Veritas InfoScale Operations Manager
- About Veritas Services and Operations Readiness Tools (SORT)
- Administering SF Oracle RAC and its components
- Administering SF Oracle RAC
- Setting the environment variables for SF Oracle RAC
- Starting or stopping SF Oracle RAC on each node
- Applying Oracle patches on SF Oracle RAC nodes
- Migrating Pluggable Databases (PDB) between Container Databases (CDB)
- Installing Veritas Volume Manager, Veritas File System, or ODM patches on SF Oracle RAC nodes
- Applying operating system updates on SF Oracle RAC nodes
- Adding storage to an SF Oracle RAC cluster
- Recovering from storage failure
- Backing up and restoring Oracle database using Veritas NetBackup
- Enhancing the performance of SF Oracle RAC clusters
- Administering SmartIO
- Creating snapshots for offhost processing
- Managing database storage efficiently using SmartTier
- Optimizing database storage using Thin Provisioning and SmartMove
- Scheduling periodic health checks for your SF Oracle RAC cluster
- Using environment variables to start and stop VCSMM modules
- Verifying the nodes in an SF Oracle RAC cluster
- Administering VCS
- About managing VCS modules
- Viewing available Veritas device drivers
- Starting and stopping VCS
- Environment variables to start and stop VCS modules
- Adding and removing LLT links
- Configuring aggregated interfaces under LLT
- Displaying the cluster details and LLT version for LLT links
- Configuring destination-based load balancing for LLT
- Enabling and disabling intelligent resource monitoring for agents manually
- Administering the AMF kernel driver
- Administering I/O fencing
- About administering I/O fencing
- About the vxfentsthdw utility
- General guidelines for using the vxfentsthdw utility
- About the vxfentsthdw command options
- Testing the coordinator disk group using the -c option of vxfentsthdw
- Performing non-destructive testing on the disks using the -r option
- Testing the shared disks using the vxfentsthdw -m option
- Testing the shared disks listed in a file using the vxfentsthdw -f option
- Testing all the disks in a disk group using the vxfentsthdw -g option
- Testing a disk with existing keys
- About the vxfenadm utility
- About the vxfenclearpre utility
- About the vxfenswap utility
- Enabling or disabling the preferred fencing policy
- About I/O fencing log files
- Migrating from disk-based fencing to server-based fencing using the installer
- Migrating from server-based fencing to disk-based fencing using the installer
- Administering the CP server
- Administering CFS
- Administering CVM
- Listing all the CVM shared disks
- Establishing CVM cluster membership manually
- Changing the CVM master manually
- Importing a shared disk group manually
- Deporting a shared disk group manually
- Starting shared volumes manually
- Verifying if CVM is running in an SF Oracle RAC cluster
- Verifying CVM membership state
- Verifying the state of CVM shared disk groups
- Verifying the activation mode
- Administering Flexible Storage Sharing
- About Flexible Storage Sharing disk support
- About the volume layout for Flexible Storage Sharing disk groups
- Setting the host prefix
- Exporting a disk for Flexible Storage Sharing
- Setting the Flexible Storage Sharing attribute on a disk group
- Using the host disk class and allocating storage
- Administering mirrored volumes using vxassist
- Displaying exported disks and network shared disk groups
- Tuning LLT for memory and performance in FSS environments
- Backing up and restoring disk group configuration data
- Administering SF Oracle RAC global clusters
- Administering SF Oracle RAC
- Overview of Storage Foundation for Oracle RAC
- Section II. Performance and troubleshooting
- Troubleshooting SF Oracle RAC
- About troubleshooting SF Oracle RAC
- Restarting the installer after a failed network connection
- Installer cannot create UUID for the cluster
- Troubleshooting SF Oracle RAC pre-installation check failures
- Troubleshooting LLT health check warning messages
- Troubleshooting I/O fencing
- SCSI reservation errors during bootup
- The vxfentsthdw utility fails when SCSI TEST UNIT READY command fails
- Node is unable to join cluster while another node is being ejected
- System panics to prevent potential data corruption
- Cluster ID on the I/O fencing key of coordinator disk does not match the local cluster's ID
- Fencing startup reports preexisting split-brain
- Registered keys are lost on the coordinator disks
- Replacing defective disks when the cluster is offline
- Troubleshooting I/O fencing health check warning messages
- Troubleshooting CP server
- Troubleshooting server-based fencing on the SF Oracle RAC cluster nodes
- Issues during online migration of coordination points
- Troubleshooting Cluster Volume Manager in SF Oracle RAC clusters
- Restoring communication between host and disks after cable disconnection
- Shared disk group cannot be imported in SF Oracle RAC cluster
- Error importing shared disk groups in SF Oracle RAC cluster
- Unable to start CVM in SF Oracle RAC cluster
- CVM group is not online after adding a node to the SF Oracle RAC cluster
- CVMVolDg not online even though CVMCluster is online in SF Oracle RAC cluster
- Shared disks not visible in SF Oracle RAC cluster
- Troubleshooting CFS
- Troubleshooting interconnects
- Troubleshooting Oracle
- Error when starting an Oracle instance in SF Oracle RAC
- Clearing Oracle group faults
- Oracle log files show shutdown called even when not shutdown manually
- DBCA fails while creating an Oracle RAC database
- Oracle's clusterware processes fail to start
- Oracle Clusterware fails after restart
- Troubleshooting the Virtual IP (VIP) configuration in an SF Oracle RAC cluster
- Troubleshooting Oracle Clusterware health check warning messages in SF Oracle RAC clusters
- Troubleshooting ODM in SF Oracle RAC clusters
- Troubleshooting Flex ASM in SF Oracle RAC clusters
- Prevention and recovery strategies
- Tunable parameters
- Troubleshooting SF Oracle RAC
- Section III. Reference
Flexible Storage Sharing use cases
The following list includes several use cases for which you would want to use the FSS feature:
Use of local storage in current use cases | The FSS feature supports all current use cases of the Storage Foundation for Oracle RAC (SF Oracle RAC) stack without requiring SAN-based storage. |
Off-host processing | Data Migration:
Back-up/Snapshots: An additional node can take a back-up by joining the cluster and reading from volumes/snapshots that are hosted on the DAS/shared storage, which is connected to one or more nodes of the cluster, but not the host taking the back-up. |
DAS SSD benefits leveraged with existing SF Oracle RAC features |
|
FSS with SmartIO for file system caching | If the nodes in the cluster have internal SSDs as well as HDDs, the HDDs can be shared over the network using FSS. You can use SmartIO to set up a read/write-back cache using the SSDs. The read cache can service volumes created using the network-shared HDDs. |
FSS with SmartIO for remote caching | FSS works with SmartIO to provide caching services for nodes that do not have local SSD devices. In this scenario, Flexible Storage Sharing (FSS) exports SSDs from nodes that have a local SSD. FSS then creates a pool of the exported SSDs in the cluster. From this shared pool, a cache area is created for each node in the cluster. Each cache area is accessible only to that particular node for which it is created. The cache area can be of type, VxVM or VxFS. The cluster must be a CVM cluster. The volume layout of the cache area on remote SSDs follows the simple stripe layout, not the default FSS allocation policy of mirroring across host. If the caching operation degrades performance on a particular volume, then caching is disabled for that particular volume. The volumes that are used to create cache areas must be created on disk groups with disk group version 200 or later. However, data volumes that are created on disk groups with disk group version 190 or later can access the cache area created on FSS exported devices. Note: CFS write-back caching is not supported for cache areas created on remote SSDs. For more information, see the document Veritas InfoScale SmartIO for Solid State Drives Solutions Guide. |
Campus cluster configuration | Campus clusters can be set up without the need for Fibre Channel (FC) SAN connectivity between sites. |
FSS in cloud environments | The Flexible Shared Storage (FSS) Technology allows you to overcome the limitations of 'Share-Nothing' storage in cloud environments. FSS enables you to create shared-nothing clusters by sharing cloud block storage over the network. For details, see the Veritas InfoScale Solutions in Cloud Environments document. |