NetBackup™ Commands Reference Guide

Last Published:
Product(s): NetBackup (10.3.0.1, 10.3)
  1. Introduction
    1.  
      About NetBackup commands
    2.  
      Navigating multiple menu levels
    3.  
      NetBackup command conventions
    4.  
      NetBackup Media Manager command notes
    5.  
      IPV6 updates
  2. Appendix A. NetBackup Commands
    1.  
      acsd
    2.  
      backupdbtrace
    3.  
      backuptrace
    4.  
      bmrc
    5.  
      bmrconfig
    6.  
      bmrepadm
    7.  
      bmrprep
    8.  
      bmrs
    9.  
      bmrsrtadm
    10.  
      bp
    11.  
      bparchive
    12.  
      bpbackup
    13.  
      bpbackupdb
    14.  
      bpcatarc
    15.  
      bpcatlist
    16.  
      bpcatres
    17.  
      bpcatrm
    18.  
      bpcd
    19.  
      bpchangeprimary
    20.  
      bpcleanrestore
    21.  
      bpclient
    22.  
      bpclimagelist
    23.  
      bpclntcmd
    24.  
      bpclusterutil
    25.  
      bpcompatd
    26.  
      bpconfig
    27.  
      bpdbjobs
    28.  
      bpdbm
    29.  
      bpdgclone
    30.  
      bpdown
    31.  
      bpduplicate
    32.  
      bperror
    33.  
      bpexpdate
    34.  
      bpfis
    35.  
      bpflist
    36.  
      bpgetconfig
    37.  
      bpgetdebuglog
    38.  
      bpimage
    39.  
      bpimagelist
    40.  
      bpimmedia
    41.  
      bpimport
    42.  
      bpinst
    43.  
      bpkeyfile
    44.  
      bpkeyutil
    45.  
      bplabel
    46.  
      bplist
    47.  
      bpmedia
    48.  
      bpmedialist
    49.  
      bpminlicense
    50.  
      bpnbat
    51.  
      bpnbaz
    52.  
      bppficorr
    53.  
      bpplcatdrinfo
    54.  
      bpplclients
    55.  
      bppldelete
    56.  
      bpplinclude
    57.  
      bpplinfo
    58.  
      bppllist
    59.  
      bpplsched
    60.  
      bpplschedrep
    61.  
      bpplschedwin
    62.  
      bppolicynew
    63.  
      bpps
    64.  
      bprd
    65.  
      bprecover
    66.  
      bprestore
    67.  
      bpretlevel
    68.  
      bpschedule
    69.  
      bpschedulerep
    70.  
      bpsetconfig
    71.  
      bpstsinfo
    72.  
      bpstuadd
    73.  
      bpstudel
    74.  
      bpstulist
    75.  
      bpsturep
    76.  
      bptestbpcd
    77.  
      bptestnetconn
    78.  
      bpup
    79.  
      bpverify
    80.  
      cat_convert
    81.  
      cat_export
    82.  
      cat_import
    83.  
      configureCerts
    84.  
      configureMQ
    85.  
      configureWebServerCerts
    86.  
      create_nbdb
    87.  
      csconfig cldinstance
    88.  
      csconfig cldprovider
    89.  
      csconfig meter
    90.  
      csconfig reinitialize
    91.  
      csconfig throttle
    92.  
      duplicatetrace
    93.  
      importtrace
    94.  
      jbpSA
    95.  
      jnbSA
    96.  
      ltid
    97.  
      mklogdir
    98.  
      msdpcldutil
    99.  
      nbauditreport
    100.  
      nbcallhomeproxyconfig
    101.  
      nbcatsync
    102.  
      NBCC
    103.  
      NBCCR
    104.  
      nbcertcmd
    105.  
      nbcertupdater
    106.  
      nbcldutil
    107.  
      nbcmdrun
    108.  
      nbcomponentupdate
    109.  
      nbcplogs
    110.  
      nbcredkeyutil
    111.  
      nbdb_admin
    112.  
      nbdb_backup
    113.  
      nbdb_move
    114.  
      nbdb_ping
    115.  
      nbdb_restore
    116.  
      nbdb_unload
    117.  
      nbdb2adutl
    118.  
      nbdbms_start_server
    119.  
      nbdbms_start_stop
    120.  
      nbdc
    121.  
      nbdecommission
    122.  
      nbdelete
    123.  
      nbdeployutil
    124.  
      nbdevconfig
    125.  
      nbdevquery
    126.  
      nbdiscover
    127.  
      nbdna
    128.  
      nbemm
    129.  
      nbemmcmd
    130.  
      nbfindfile
    131.  
      nbfirescan
    132.  
      nbfp
    133.  
      nbftadm
    134.  
      nbftconfig
    135.  
      nbgetconfig
    136.  
      nbhba
    137.  
      nbholdutil
    138.  
      nbhostidentity
    139.  
      nbhostmgmt
    140.  
      nbhypervtool
    141.  
      nbidpcmd
    142.  
      nbimageshare
    143.  
      nbinstallcmd
    144.  
      nbjm
    145.  
      nbkmiputil
    146.  
      nbkmscmd
    147.  
      nbkmsutil
    148.  
      nboraadm
    149.  
      nborair
    150.  
      nbpem
    151.  
      nbpemreq
    152.  
      nbmariadb
    153.  
      nbmlb
    154.  
      nbperfchk
    155.  
      nbplupgrade
    156.  
      nbrb
    157.  
      nbrbutil
    158.  
      nbreplicate
    159.  
      nbrepo
    160.  
      nbrestorevm
    161.  
      nbseccmd
    162.  
      nbserviceusercmd
    163.  
      nbsetconfig
    164.  
      nbshvault
    165.  
      nbsmartdiag
    166.  
      nbsnapimport
    167.  
      nbsnapreplicate
    168.  
      nbsqladm
    169.  
      nbsqlite
    170.  
      nbstl
    171.  
      nbstlutil
    172.  
      nbstop
    173.  
      nbsu
    174.  
      nbsvrgrp
    175.  
      netbackup_deployment_insights
    176.  
      resilient_clients
    177.  
      restoretrace
    178.  
      stopltid
    179.  
      tldd
    180.  
      tldcd
    181.  
      tpautoconf
    182.  
      tpclean
    183.  
      tpconfig
    184.  
      tpext
    185.  
      tpreq
    186.  
      tpunmount
    187.  
      verifytrace
    188.  
      vltadm
    189.  
      vltcontainers
    190.  
      vlteject
    191.  
      vltinject
    192.  
      vltoffsitemedia
    193.  
      vltopmenu
    194.  
      vltrun
    195.  
      vmadd
    196.  
      vmchange
    197.  
      vmcheckxxx
    198.  
      vmd
    199.  
      vmdelete
    200.  
      vmoprcmd
    201.  
      vmphyinv
    202.  
      vmpool
    203.  
      vmquery
    204.  
      vmrule
    205.  
      vmupdate
    206.  
      vnetd
    207.  
      vssat
    208.  
      vwcp_manage
    209.  
      vxlogcfg
    210.  
      vxlogmgr
    211.  
      vxlogview
    212.  
      W2KOption

Name

vltoffsitemedia — list off-site parameter values for a group of media, or change the off-site parameter value for a single media

SYNOPSIS

vltoffsitemedia -list [-W] [-vault vault_name] [-voldbhost host_name]

vltoffsitemedia -change -m media_id [-voldbhost host_name] [-d media_description] [-vltname vault_name] [-vltsent date][-vltreturn date] [-vltslot slot_no] [-vltcid container_id] [-vltsession session_id]

vltoffsitemedia -version

 

On UNIX systems, the directory path to this command is /usr/openv/netbackup/bin/

On Windows systems, the directory path to this command is install_path\NetBackup\bin\

DESCRIPTION

vltoffsitemedia allows the user to change the vault-specific parameters of a given media. This command lets the user change one or more parameters by using a single command. It lets the user view the various vault parameters of all media for a particular EMM server or vault.

If you create the following directory with public-write access, vltoffsitemedia creates a daily debug log in this directory:

UNIX: /usr/openv/netbackup/logs/vault

Windows: install_path\netbackup\logs\vault

The log is called log.DDMMYY (where DDMMYY is the current date). You then can use this file that for troubleshooting.

Public-write access is needed because not all executables that write to this file can run as root.

OPTIONS

-change

Changes the attributes of the specified volume.

-d media_description

Specifies the description for the volume.

To configure NetBackup so that the media description field is cleared automatically when volumes are returned to the robot, set the VAULT_CLEAR_MEDIA_DESC parameter in EMM.

-list

Lists the off-site parameters for the media in the local EMM database. To restrict the list to a specific vault for the local EMM database, include the -vault option with the command. To list the off-site parameters for media for a specific EMM database, include the -voldbhost option with the command.

-m media_id

Media ID of the volume whose vault parameters are to be changed.

-vault vault_name

Specifies the name of the vault for which all media IDs and their vault-specific parameters are listed.

-version

Displays the vltoffsitemedia version and exit.

-vltcid container_id

Specifies the container in which a volume is stored. container_id (a string of up to 29 alphanumeric characters (no spaces) specifies the new container for the volume. You must specify an existing container ID. You cannot assign media from one EMM server to a container that has media from a different EMM server. Use the -m option to specify the media ID of the volume.

-vltname vault_name

Specifies the name of the logical vault that is configured for the robot that ejected the volume.

-vltreturn date

Specifies the date and time the media was requested for return from the vault vendor. For Catalog Backup volumes, this date is the date that the media is requested for return from the vault vendor.

The required date and time values format in NetBackup commands varies according to your locale. The /usr/openv/msg/.conf file (UNIX) and the install_path\VERITAS\msg\LC.CONF file (Windows) contain information such as the date-time formats for each supported locale. The files contain specific instructions on how to add or modify the list of supported locales and formats.

See the "About specifying the locale of the NetBackup installation" topic in the NetBackup Administrator's Guide, Volume II for more information.

-vltsent date

Specifies the date and time the media was sent to the off-site vault.

The required date and time values format in NetBackup commands varies according to your locale. The /usr/openv/msg/.conf file (UNIX) and the install_path\VERITAS\msg\LC.CONF file (Windows) contain information such as the date-time formats for each supported locale. The files contain specific instructions on how to add or modify the list of supported locales and formats.

See the "About specifying the locale of the NetBackup installation" topic in the NetBackup Administrator's Guide, Volume II for more information.

mm/dd/yyyy [hh[:mm[:ss]]]
-vltsession session_id

Specifies the identifier of the Vault session that ejected this media.

-vltslot slot_no

Specifies the vault vendor's slot number for the slot that this volume occupies.

-voldbhost host_name

Specifies the name of the EMM server.

-W

Specifies the parsable output format for the media off-site parameters. For containers, the output includes the length of the container description, the container description, and the container ID. The output header line is a space that is separated line of column labels; the output data lines are space-separated fields.

EXAMPLES

Example 1 - Change the vault name and the vault sent dates of the media with the ID BYQ.

vltoffsitemedia -change -m BYQ -vltname THISTLE -vltsent 08/01/2012 
12:22:00

Example 2 - Change the vault slot number to 100 for a media with ID 000012.

vltoffsitemedia -change -m 000012 -vltslot 100

Example 3 - Clear out the vault-specific fields for a media.

vltoffsitemedia -change -m 000012 -vltname "" -vltsession 0 -vltslot 
0 -vltsent 0 -vltreturn 0

or:

vltoffsitemedia -change -m 000012 -vltname - -vltsession 0 -vltslot 
0 -vltsent 00/00/00 -vltreturn 00/00/00

Example 4 - Clear the container ID and media description of volume ABC123.

vltoffsitemedia -change -m ABC123 -vltcid - -d ""

or:

vltoffsitemedia -change -m ABC123 -vltcid "" -d ""

The vltoffsitemedia command uses the Media Manager commands to query or update the EMM database.

If the vltoffsitemedia command fails, look at the debug log on the following directory for detailed information about the actual Media Manager command that failed:

UNIX systems: usr/openv/netbackup/logs/vault

Windows systems: install_path\netbackup\logs\vault

For more information on the status codes that Media Manager commands return, see the NetBackup Status Codes Reference Guide.

RETURN VALUES

Vault may exit with a status code greater than 255. Such status codes are called "extended exit status codes." For such a case, the exit status that is returned to the system is 252. The actual exit status is written to stderr in the format, EXIT status = exit status

The extended exit status values are documented in the NetBackup Status Codes Reference Guide and in the NetBackup Troubleshooter Wizard.