Please enter search query.
Search <book_title>...
Veritas Access Appliance 8.3 Release Notes
Last Published:
2025-04-17
Product(s):
Appliances (8.3)
Platform: Veritas 3350,Veritas 3340,Veritas 3360
- Overview of Access Appliance
- Changes in this release
- Software limitations
- Limitations related to installation and upgrade
- Limitation related to replication
- Known issues
- Access Appliance known issues
- CIFS issues
- General issues
- GUI issues
- Infrastructure issues
- Installation and configuration issues
- MSDP-C issues
- Networking issues
- NFS issues
- ObjectAccess issues
- Replication issues
- STIG issues
- Storage issues
- Upgrade issues
- Veritas Data Deduplication issues
- Access Appliance operational notes
- CIFS issues
- Access Appliance known issues
- Getting help
Earlier set outbound connection rules get removed if the cluster is restarted after dedupe stop command
When multiple Veritas Data Deduplication instances are configured in an IRE domain cluster, and subnets and schedules are set using the MSDP restricted shell for all the Veritas Data Deduplication instances; if any of the instances is stopped and the cluster is restarted, the outbound connection rules corresponding to that instance is lost after the restart operation. This is by design and the outbound connection rules, if any, are applied back only if the stopped instance(s) are started back.
(IA-52794)
Workaround:
There is no workaround for this issue.