NetBackup IT Analytics Data Collector Installation Guide for Replication Manager

Last Published:
Product(s): NetBackup IT Analytics (11.2)

Install Data Collector binaries on Windows (without configuration)

This Data Collector installation allows you to install the collector independent of the portal software installation. The collector remains disconnected from the portal until you configure it using a response file, that contains credentials of the Data Collector created on the NetBackup IT Analytics Portal and the data receiver.

Install the Data Collector

To install a Data Collector:

  1. Download and mount the Data Collector installer ISO file.
  2. Install the Data Collector using silentinstall.cmd and follow the installation prompt.

    You can install the Data Collector in the following options:

    • Install at default location:

      <ISO_MOUNT_DRIVE>:\silentinstall.cmd /INSTALL_TYPE:INSTALL
    • Install at custom location:

      <ISO_MOUNT_DRIVE>:\silentinstall.cmd /INSTALL_PATH:<custom location for dc installation> /INSTALL_TYPE:INSTALL

    The independent Data Collector installation is complete.

Configure the Data Collector using responsefile

A sample responsefile is saved when you install the Data Collector. To connect the Data Collector with the NetBackup IT Analytics Portal, you must configure its responsefile with the credentials of the Data Collector created on the portal and run a configuration command as described in the procedure below.

To configure the Data Collector:

  1. Obtain the following details from the NetBackup IT Analytics Portal:
    • Data Collector name

    • Data Collector passcode

    • Key file downloaded from the Portal

    • Data receiver URL

    • Proxy server configuration details

  2. Update the responseFile.cmd with the above values.
    @ECHO OFF
    
    REM -------------------------------------------------
    SET DATACOLLECTOR_NAME=
    REM -------------------------------------------------
    REM  Description: Enter Data Collector Name. This Data Collector name will be used to authenticate the Data Collector with the Data Receiver.
    REM  Required: True
    
    REM -------------------------------------------------
    SET DATACOLLECTOR_PASSCODE=
    REM -------------------------------------------------
    REM  Description: Enter Data Collector Passcode. This Data Collector passcode will be used to authenticate the Data Collector with the Data Receiver.
    REM  Required: True
    
    REM -------------------------------------------------
    SET DATARECEIVER_URL=
    REM -------------------------------------------------
    REM  Description: Enter Data Receiver URL. Enter the URL to the Data Receiver. Ex: http(s)://itanalyticsagent.mycompany.com.
    REM  Required: True
    REM  Example: http://itanalyticsagent.mycompany.com , https://itanalyticsagent.mycompany.com
    
    REM -------------------------------------------------
    SET DATACOLLECTOR_KEY_FILE_PATH=
    REM -------------------------------------------------
    REM  Description: Enter the Data Collector's Key File path. The file path must include name of the file that was downloaded from the Portal.
    REM  Valid input values: Absolute path of key file
    REM  Required: True
    
    REM -------------------------------------------------
    SET HTTP_PROXY_CONF=N
    REM -------------------------------------------------
    REM  Description: It indicate whether proxy should be configured or not
    REM  Valid input values: Y,N
    REM  Default value: N
    
    REM -------------------------------------------------
    SET PROXY_HTTP_URL=
    REM -------------------------------------------------
    REM  Description: IP/hostname for HTTP Proxy
    REM  Valid input values: 10.20.30.40, localhost
    
    REM -------------------------------------------------
    SET PROXY_HTTP_PORT=
    REM -------------------------------------------------
    REM  Description: Port for HTTP proxy
    REM  Valid input values: Any number between 0 and 65535
    
    REM -------------------------------------------------
    SET PROXY_HTTPS_URL=
    REM -------------------------------------------------
    REM  Description: IP/hostname for HTTPS Proxy
    REM  Valid input values: 10.20.30.40, localhost
    
    REM -------------------------------------------------
    SET PROXY_HTTPS_PORT=
    REM -------------------------------------------------
    REM  Description: Port for HTTPS proxy
    REM  Valid input values: Any number between 0 and 65535
    
    REM -------------------------------------------------
    SET PROXY_USERID=
    REM -------------------------------------------------
    REM  Description: Proxy UserId
    REM  Default value:
    
    REM -------------------------------------------------
    SET PROXY_PASSWORD=
    REM -------------------------------------------------
    REM  Description: Proxy user password
    REM  Default value:
    
    REM -------------------------------------------------
    SET PROXY_NOT_FOR=
    REM -------------------------------------------------
    REM  Description: List of IP/hostname which should be excluded for proxy
    REM  Default value:

    The Data Collector installation without connecting it with the portal is complete

Configure the Data Collector using responsefile

To configure the installation, run the below command from command prompt:

<ISO_MOUNT_DRIVE>:\silentinstall.cmd /RESPFILE:<responsefile_path> /INSTALL_PATH:<Data_Collector_installation_path> /INSTALL_TYPE:CONFIG

or

<INATALL_PATH>\DC\configure.cmd" /RESPFILE:<response_file_path> /INSTALL_TYPE:CONFIG

Uninstall Data Collector

Remove the Data Collector installation from Control Panel > Add and Remove Programs menu.