NetBackup IT Analytics Data Collector Installation Guide for Fabric Manager

Last Published:
Product(s): NetBackup IT Analytics (11.2)
  1. Fabric Manager Data Collection overview
    1.  
      Introduction
    2.  
      Fabric Manager: Collection of SAN switch data
    3.  
      Switch zone alias collection
  2. Pre-Installation setup for Brocade switch
    1.  
      Pre-Installation setup for Brocade switch
    2.  
      Prerequisites for adding Data Collectors (Brocade switch)
    3.  
      Upgrade troubleshooting: Brocade BNA SMI-S (CIM) server and Java 11
    4.  
      Supported switches
    5.  
      Brocade switches: Default ports and firewall considerations
    6.  
      Installation overview (Brocade switch)
    7.  
      Brocade switch Data Collector policy
  3. Pre-Installation setup for Cisco switch
    1.  
      Pre-Installation setup for Cisco switch
    2.  
      Prerequisites for adding Data Collectors (Cisco switch)
    3.  
      Upgrade troubleshooting: Cisco DCNM SMI-S (CIM) server and Java 11
    4.  
      Cisco switches: Default ports and firewall considerations
    5.  
      Installation overview (Cisco switch)
    6.  
      Cisco switch Data Collection policy
    7.  
      Before you start Cisco switch Data Collection
  4. Pre-Installation setup for Brocade Zone alias
    1.  
      Pre-Installation setup for Brocade zone alias
    2.  
      Prerequisites for adding Data Collectors (Brocade zone alias)
    3.  
      Brocade switches: Default ports and firewall considerations
    4.  
      Installation overview (Brocade zone alias)
    5.  
      Brocade zone alias Data Collector policy
  5. Pre-Installation setup Cisco Zone alias
    1.  
      Pre-Installation setup Cisco zone alias
    2.  
      Prerequisites for adding Data Collectors (Cisco zone alias)
    3.  
      Cisco switches: Default ports and firewall considerations
    4.  
      Installation overview (Cisco Zone Alias)
    5.  
      Cisco zone alias Data Collector policy
  6. Installing the Data Collector software
    1.  
      Introduction
    2.  
      Installing the WMI Proxy service (Windows host resources only)
    3.  
      Testing WMI connectivity
    4.  
      Considerations to install Data Collector on non-English systems
    5.  
      Install Data Collector Software on Windows
    6.  
      Install Data Collector software on Linux
    7.  
      Deploy Data Collector in native Kubernetes environment
    8.  
      Configure Data Collector manually for Veritas NetBackup
    9.  
      Install Data Collector binaries on Windows (without configuration)
    10.  
      Install Data Collector binaries on Linux host (without configuration)
  7. Validating Data Collection
    1.  
      Validation methods
    2.  
      Data Collectors: Vendor-Specific validation methods
    3. Working with on-demand Data Collection
      1.  
        View real-time logging during an on-demand collection
    4.  
      Using the CLI check install utility
    5.  
      List Data Collector configurations
  8. Uninstalling the Data Collector
    1.  
      Uninstall the Data Collector on Linux
    2.  
      Uninstall the Data Collector on Windows
  9. Manually starting the Data Collector
    1.  
      Introduction
  10. Appendix A. Firewall configuration: Default ports
    1.  
      Firewall configuration: Default ports

Testing WMI connectivity

The Windows Management Instrumentation (WMI) Proxy is used by NetBackup IT Analytics to collect data from Windows hosts. Should you have connectivity issues, these steps can be taken to test and troubleshoot connectivity.

To verify that WMI is working properly, take the following steps:

  1. Log in to the Data Collector server as an Administrator.

  2. From the Windows Start menu, type Run in the search box to launch the following window where you will enter wbemtest.exe and click OK.

  3. In the Windows Management Instrumentation Tester window, click Connect.

  4. In the Connect window, preface the Namespace entry with the IP address or hostname of the target remote server in the following format:

    \\<IP Address>\root\cimv2
  5. Complete the following fields in the Connect window and then click Connect.

    • User - Enter the credentials for accessing the remote computer. This may require you to enable RPC (the remote procedure call protocol) on the remote computer.

    • Password

    • Authority: Enter NTLMDOMAIN:<NameOfDomain>

      where NameOfDomain is the domain of the user account specified in the User field.

  6. Click Enum Classes.

  7. In the Superclass Info window, select the Recursive radio button, but do not enter a superclass name. Then, click OK.

  8. The WMI Tester will generate a list of classes. If this list does not appear, go to the Microsoft Developer Network web site for troubleshooting help.

    http://msdn.microsoft.com/en-us/library/ms735120.aspx