Cluster Server 7.3.1 Configuration and Upgrade Guide - Solaris
- Section I. Configuring Cluster Server using the script-based installer
- I/O fencing requirements
- Preparing to configure VCS clusters for data integrity
- About planning to configure I/O fencing
- Setting up the CP server
- Configuring VCS
- Configuring a secure cluster node by node
- Verifying and updating licenses on the system
- Configuring VCS clusters for data integrity
- Setting up disk-based I/O fencing using installer
- Setting up server-based I/O fencing using installer
- Section II. Automated configuration using response files
- Performing an automated VCS configuration
- Performing an automated I/O fencing configuration using response files
- Section III. Manual configuration
- Manually configuring VCS
- Configuring LLT manually
- Configuring VCS manually
- Configuring VCS in single node mode
- Modifying the VCS configuration
- Manually configuring the clusters for data integrity
- Setting up disk-based I/O fencing manually
- Setting up server-based I/O fencing manually
- Configuring server-based fencing on the VCS cluster manually
- Setting up non-SCSI-3 fencing in virtual environments manually
- Setting up majority-based I/O fencing manually
- Manually configuring VCS
- Section IV. Upgrading VCS
- Planning to upgrade VCS
- Performing a VCS upgrade using the installer
- Tasks to perform after upgrading to 2048 bit key and SHA256 signature certificates
- Performing an online upgrade
- Performing a rolling upgrade of VCS
- Performing a phased upgrade of VCS
- About phased upgrade
- Performing a phased upgrade using the product installer
- Performing an automated VCS upgrade using response files
- Upgrading VCS using Live Upgrade and Boot Environment upgrade
- Planning to upgrade VCS
- Section V. Adding and removing cluster nodes
- Adding a node to a single-node cluster
- Adding a node to a single-node cluster
- Adding a node to a multi-node VCS cluster
- Manually adding a node to a cluster
- Setting up the node to run in secure mode
- Configuring I/O fencing on the new node
- Adding a node using response files
- Removing a node from a VCS cluster
- Removing a node from a VCS cluster
- Removing a node from a VCS cluster
- Adding a node to a single-node cluster
- Section VI. Installation reference
- Appendix A. Services and ports
- Appendix B. Configuration files
- Appendix C. Configuring LLT over UDP
- Using the UDP layer for LLT
- Manually configuring LLT over UDP using IPv4
- Manually configuring LLT over UDP using IPv6
- Appendix D. Configuring the secure shell or the remote shell for communications
- Appendix E. Installation script options
- Appendix F. Troubleshooting VCS configuration
- Appendix G. Sample VCS cluster setup diagrams for CP server-based I/O fencing
- Appendix H. Reconciling major/minor numbers for NFS shared disks
- Appendix I. Upgrading the Steward process
Issues during fencing startup on VCS cluster nodes set up for server-based fencing
Table: Fencing startup issues on VCS cluster (client cluster) nodes
Issue | Description and resolution |
---|---|
cpsadm command on the VCS cluster gives connection error |
If you receive a connection error message after issuing the cpsadm command on the VCS cluster, perform the following actions:
|
Authorization failure | Authorization failure occurs when the nodes on the client clusters and or users are not added in the CP server configuration. Therefore, fencing on the VCS cluster (client cluster) node is not allowed to access the CP server and register itself on the CP server. Fencing fails to come up if it fails to register with a majority of the coordination points. To resolve this issue, add the client cluster node and user in the CP server configuration and restart fencing. See Preparing the CP servers manually for use by the VCS cluster. |
Authentication failure | If you had configured secure communication between the CP server and the VCS cluster (client cluster) nodes, authentication failure can occur due to the following causes:
|