- Using the NetBackup WebSocket Service (NBWSS) for communication with a cloud application
- Examples of NBWSS messages
- Configuring WebSocket endpoints for NBWSS
- Troubleshooting NBWSS
- NBWSS issues
Other NetBackup notification messages
The following messages are the notifications that NetBackup sent to an endpoint for a restore job and for image deletion. The third message is an example of multiple notifications in one message.
Restore job done
{ "version": "1.0", "id": "8E909940-AD50-4543-8AEA-B52003818925", "type": "NOTIFICATION", "subType": "REQUEST", "timeStamp": 1459812309, "payload": [ { "notificationType": "INFO", "object": "JOB", "data": [ { "scheduleType": "ST_FULL", "clientName": "masterserver2.domain.com", "status": 0, "startTime": 1459830185, "state": "DONE", "policyName": "", "parentJobId": 147, "jobId": 147, "policyType": "STANDARD", "jobType": "RESTORE" } ] } ] }
Image deletion
{ "version": "1.0", "id": "15AAF7BA-C082-4996-A55D-7C4745D4D1E9", "type": "NOTIFICATION", "subType": "REQUEST", "timeStamp": 1459814495, "payload": [ { "notificationType": "INFO", "object": "IMAGE", "data": [ { "clientType": "VMWARE", "clientName": "localhost", "backupTime": 1458601200, "createdTime": 1459832492, "operationId": "DELETE", "backupId": "localhost_1458601200" } ] } ] }
Note: If the NetBackup master server uses Auto Image Replication (AIR), the following notification may be issued regarding image deletion:
{ "version": "1.0", "id": "E38DD102-98BC-4590-8E09-85B0A0EA31CE", "type": "NOTIFICATION", "subType": "REQUEST", "timeStamp": 1471471464, "payload": [ { "notificationType": "INFO", "object": "IMAGE", "data": [ { "clientType": "STANDARD", "clientName": "localhost", "backupTime": 1471469619, "createdTime": 1471485862, "operationId": "UPDATE", "backupId": "localhost_1471469619" }, { "clientType": "STANDARD", "clientName": "localhost", "backupTime": 1471469619, "createdTime": 1471485862, "operationId": "NO_LOCAL_COPY_AVAILABLE", "backupId": "localhost_1471469619" } ] } ] }
Multiple notifications in one message
{ "version": "1.0", "id": "608FE0C1-B03C-421D-8876-E3730A7855AF", "type": "NOTIFICATION", "subType": "REQUEST", "timeStamp": 1459811724, "payload": [ { "notificationType": "INFO", "object": "JOB", "data": [ { "scheduleType": "ST_FULL", "clientName": "DummyTestVM", "status": 0, "startTime": 1459829698, "state": "DONE", "policyName": "vmware2", "parentJobId": 145, "jobId": 146, "policyType": "VMWARE", "jobType": "BACKUP" } ] }, { "notificationType": "INFO", "object": "IMAGE", "data": [ { "clientType": "VMWARE", "clientName": "DummyTestVM", "backupTime": 1459811698, "createdTime": 1459829720, "operationId": "UPDATE", "backupId": "DummyTestVM_1459811698" }, { "clientType": "VMWARE", "clientName": "DummyTestVM", "backupTime": 1459811686, "createdTime": 1459829721, "operationId": "UPDATE", "backupId": "DummyTestVM_1459811686" } ] } ] }