Veritas Velocity™ User's Guide
- Getting to know Velocity
- Setting up Velocity
- Velocity administrator's checklist for setting up Veritas Velocity
- Database administrator's checklist for setting up Veritas Velocity
- Sandbox user's checklist for setting up Veritas Velocity
- How to set up the Velocity Storage Server
- Deploying the Velocity Storage Server image on a virtual machine
- Velocity Appliance initial configuration requirements
- Configuring network and storage settings for the Velocity Storage Server in a virtual environment
- Registering the Velocity Storage Server
- Joining the Velocity Storage Server to the Active Directory domain
- Adding a Certificate Authority signed certificate to the Velocity Storage Server
- How to set up the Velocity Client
- Deleting a Velocity Client
- Configuring a proxy server for Velocity
- Required and optional ports for Velocity
- Installing the NetBackup Client on the Velocity Storage Server
- Setting up the Velocity on-premises management server
- How to set up the Velocity on-premises management server
- Deploying the Velocity on-premises management server image on a virtual machine
- Configuring the network settings for the Velocity on-premises management server
- Configuring Active Directory/LDAP settings on the Velocity on-premises management server
- Adding users to the Velocity on-premises management server
- Upgrading the Velocity on-premises management server
- Upgrading Velocity
- How to upgrade to Velocity version 2.9
- Finding the Velocity component version numbers
- Downloading and transferring software updates to the Velocity Storage Server
- Removing previous upgrade files
- Upgrading the Velocity Storage Server
- Upgrading the Velocity Client for Linux
- Upgrading the Velocity Client for Windows
- Upgrading the Velocity Client for Solaris
- Velocity Storage Server
- About the Velocity Storage Server
- Viewing physical storage usage on the Velocity Storage Server
- About reclaiming storage space on the Veritas Velocity Storage Server
- Increasing meta and data storage capacity on the Velocity Storage Server
- Deregistering a Velocity Storage Server
- How to reset the Velocity Storage Server
- Users and roles
- Oracle database ingestion using Velocity
- How to provide copies of Oracle databases for sandboxes in Velocity
- Adding an Oracle database to ingest into Velocity
- Ingesting an Oracle database into Velocity for the first time
- Ingesting an Oracle database again after the first ingest
- Canceling an Oracle database ingestion
- How to use copy preparation to mask or sanitize sensitive data
- Masking sensitive data manually in database copies
- Masking sensitive data in database copies by using a script
- Masking sensitive data manually in database copies that are already ingested
- Masking sensitive data by using a script in database copies that are already ingested
- Disabling copy preparation for Oracle database copies
- Ingesting an Oracle database into Velocity from the command line
- About setting custom initialization parameters for a sandbox for an Oracle database copy
- Editing default options for the ingest method for Oracle databases
- Oracle database ingestion using NetBackup CoPilot
- Microsoft SQL Server database ingestion using Velocity
- Automatic ingestion of NetBackup deduplicated backups
- About using NetBackup deduplicated backups to create Velocity sandboxes
- How to set up automatic ingestion of NetBackup deduplicated backups
- Supported Oracle policy options for automatic ingestions of NetBackup deduplicated backups
- Supported SQL Server policy options for automatic ingestions of NetBackup deduplicated backups
- Adding an Oracle database source to automatically ingest NetBackup deduplicated backups
- Adding a SQL Server database source to automatically ingest NetBackup deduplicated backups
- Database sources and copies
- About database sources and copies
- Viewing details of an Oracle database source
- Viewing details of a SQL Server database source
- Changing the nickname or description of a database source
- Deleting a database source from Velocity
- About scheduling ingestions for a database source
- Viewing the ingestion schedule for a database source
- Adding an ingestion schedule to a database source
- Editing the ingestion schedule for a database source
- Deleting the ingestion schedule for a database source
- Restarting scheduled database ingestions after changing the system time or time zone on the Velocity Storage Server
- Retention periods for database sources and copies
- Viewing database copies
- Viewing the number of sandboxes that were created from a database copy
- Viewing the status of database copies
- Deleting database copies
- Sandboxes
- About sandboxes
- Creating a sandbox from an Oracle database copy
- Starting an Oracle database instance manually
- Creating a sandbox from a SQL Server database copy
- Starting a SQL database manually
- Finding your sandbox
- Viewing details about your sandboxes
- Deleting a sandbox
- Managing sandboxes when you restart the host Oracle Database server
- Unmounting a sandbox from an Oracle host server
- Database recovery
- Alerts and logs
- Managing the Velocity physical appliance
- Configuring network address settings on the Velocity physical appliance
- About IPv4-IPv6-based network support on the Velocity physical appliance
- About NIC1 (eth0) port usage on the Velocity physical appliance
- Creating a network interface bond (NIC bond) on the Velocity physical appliance
- VLAN tagging on the Velocity physical appliance
- Configuring static routes on the Velocity physical appliance
- Configuring DNS and host name mapping on the Velocity physical appliance
- Setting the host name for the Velocity physical appliance
- Using a proxy server with the Velocity physical appliance
- About WAN optimization on the Velocity physical appliance
- About the maximum transmission unit size on the Velocity physical appliance
- Setting the date and time on the Velocity physical appliance
- About the Veritas Remote Management Console on the Velocity physical appliance
- About Velocity physical appliance storage
- About users on the Velocity physical appliance
- About Velocity physical appliance checkpoints
- About factory reset on the Velocity physical appliance
- Configuring network address settings on the Velocity physical appliance
- Monitoring the Velocity physical appliance
- Velocity physical appliance security
- About Velocity physical appliance user account privileges
- About the Velocity physical appliance intrusion detection system
- About Velocity physical appliance operating system security
- About data security on the Velocity physical appliance
- About data integrity on the Velocity physical appliance
- About the Velocity physical appliance ports
- Recommended IPMI settings on the Velocity physical appliance
- Velocity REST APIs
- Getting started with Velocity REST APIs
- Authenticate a user for the Velocity REST APIs
- Get Velocity Storage Servers
- Create a share
- Find the share ID
- Find the share location
- Create a snapshot
- Find the snapshot ID
- Create a sandbox
- Find the sandbox ID
- Get a sandbox
- Delete a share
- Delete a snapshot
- Delete a sandbox
- Get templates (shares)
- Get snapshots
- List all sandboxes
- Best practices
- Troubleshooting
- NFS export paths where ingested Oracle Database sources are stored are inaccessible
- NFS export path is not created during a database ingestion
- Database ingestion fails with the Oracle error 'diskgroup {xx} space exhausted'
- After restart of the vpfsd service, links to the applications are broken
- Sandbox creation fails on an Oracle Database server
- Sandbox creation fails for a SQL Server database copy
- Sandbox creation fails after you use the --adGroups argument when you configure the Velocity Client for Windows
- Sandbox creation may take longer than usual on Oracle Database 12c
- A sandbox cannot be deleted from an Oracle Database server because the mount point is busy
- Error occurs when registering the Velocity Client; provide the Oracle DBA with access to the Velocity registration files
- Error occurs when a new sandbox name has the same name as a deleted sandbox
- Ingestions and sandboxes are stuck 'In Progress' after the Velocity Storage Server is restarted
- Glossary
- Section I. Velocity shell menu commands
- Introduction
- Appendix A. Main > Manage > Storage
- Appendix B. Main > Manage > Cloud
- Appendix C. Main > Manage > Software
- Appendix D. Main > Monitor
- Appendix E. Main > Network
- Network > Configure
- Network > Date
- Network > DNS
- Network > Gateway
- Network > Hostname
- Network > Hosts
- Network > IPv4
- Network > IPv6
- Network > NetStat
- Network > NTPServer
- Network > LinkAggregation
- Network > VLAN
- Network > WANOptimization
- Network > Ping
- Network > Proxy
- Network > SetProperty
- Network > Show
- Network > TimeZone
- Network > TraceRoute
- Network > Unconfigure
- Appendix F. Main > Settings
- Appendix G. Main > Support
Name
Main > Monitor > Hardware — Monitor the appliance hardware.
SYNOPSIS
Hardware ShowComponents
Hardware ShowErrors
Hardware ShowHealth
DESCRIPTION
Note:
This command only applies to the Veritas Velocity physical appliance.
Use this command to monitor hardware health and events on the appliance. To exit some of the monitoring commands, you need to press q or Ctrl+C.
OPTIONS
The following commands and options are available under Main > Monitor > Hardware:
- ShowComponents
Use this option to view the appliance hardware components, such as the compute node and the storage shelves, and the sub-components that are associated with those devices: Fan, disk, temperature, etc.
- ShowErrors
Use this option to view the errors that are related to the various hardware components of the appliance.
- ShowHealth
This option displays the performance and status of various hardware components of the appliance and the attached storage.
Note:
The [Item] parameter is optional. If you do not enter a value for the [Item] parameter, the data is displayed for all of the items that are associated with the hardware component.
Use the Hardware ShowHealth Appliance [Item] command to view the performance and status of a specific hardware item of the appliance. You can select any of the following items:
All/Fan/CPU/Disk/Fibrechannel/RAID/Power/Temperature/Product/PCI/ Network/Firmware/Partition/Connection/StorageStatus/DIMM
Use the Hardware ShowHealth PrimaryShelf [Item] command to view the performance and status of a specific hardware item of the Primary Storage Shelf. You can select any of the following items:
All/Fan/Disk/Power/Temperature/Product/Firmware/BBU/Controller /Volume/VolumeGroup/Connection
Use the Hardware ShowHealth ExpansionShelf [TrayID] [Item] command to view the performance and status of a specific hardware item of an Expansion Storage Shelf. You can select any of the following items: All/Fan/Disk/Power/Temperature/Product/Volume/VolumeGroup.
The [TrayID] is optional and is the ID of a specific expansion shelf that is attached to the appliance. To check the expansion shelf IDs, use the Main > Monitor > Hardware ShowComponents command.
EXAMPLES
Example 1 - Use the Monitor > Hardware CallHomeNow command to log and send the appliance heartbeat information:
abc123.Monitor> Hardware CallHomeNow Gathering hardware information. It might take about a minute... Successfully finished the operation.
Example 2 - Use the Monitor > Hardware ShowComponents command to show the various appliance hardware components:
abc123.Monitor> Hardware ShowComponents Compute Node abc123.veritas.com +-----------------------------------------------------------------------------------+ |Component| Item | |---------+-------------------------------------------------------------------------| |Appliance|fan,cpu,disk,fibrechannel,...,firmware,connection,partition,storagestatus| +-----------------------------------------------------------------------------------+ +-----------------------------------------------------------------------------------+ | Component | IDs | Item | |----------------------+------------------------------------------------------------| |Primary Storage Shelf | 99 |disk,network,fan,...,volume,raid,product,connection | +-----------------------------------------------------------------------------------+ +---------------------------------------------------------------------------+ | Component | IDs | Item | |------------------------+--------------------------------------------------| |Expansion Storage Shelf | 1,2 | product,temperature,power,disk,fan | +---------------------------------------------------------------------------+
Example 3 - Use the Monitor > Hardware ShowErrors command to show the errors that are related to the various hardware components of the appliance:
infodev5230a.Monitor> Hardware ShowErrors Compute Node abc123.veritas.com Time Monitoring Ran: Sun Apr 10 2016 21:12:18 CDT +-------------------------------------------------------------------------------------+ | Power Supply Information | |+-----------------------------------------------------------------------------------+| ||ID | Status | Wattage | HighWaterMark | State |Acknowledge || ||---+----------------------+--------------+------------------+---------+------------|| ||2 |Failure detected |0.00 Watts |920.00 Watts |Warning |No || |+-----------------------------------------------------------------------------------+| +-------------------------------------------------------------------------------------+
Example 4 - Use the Monitor > Hardware ShowHealth Appliance Disk command to view the disk information for the appliance compute node:
abc123.Monitor> Hardware ShowHealth Appliance Disk +---------------------------------------------------------------------------------------------------------------------------------------+ | Disk Information | |+----+-------------+---------------------+---------------+------------------+---------------+----------+------+--------------+-------+ | || ID | Slot Number | Status | Foreign State | Firmware Version | Serial Number | Capacity | Type | Enclosure ID | State | | |+----+-------------+---------------------+---------------+------------------+---------------+----------+------+--------------+-------+ | || - | 0 | Online,Spun Up | None | 0003 | Z1W1G82V | 931.51GB | SAS | 252 | OK | | |+----+-------------+---------------------+---------------+------------------+---------------+----------+------+--------------+-------+ | || - | 1 | Online,Spun Up | None | 0003 | Z1W1G6RV | 931.51GB | SAS | 252 | OK | | |+----+-------------+---------------------+---------------+------------------+---------------+----------+------+--------------+-------+ | || - | 2 | Online,Spun Up | None | 0003 | Z1W1G75A | 931.51GB | SAS | 252 | OK | | |+----+-------------+---------------------+---------------+------------------+---------------+----------+------+--------------+-------+ | || - | 3 | Online,Spun Up | None | 0003 | Z1W1G641 | 931.51GB | SAS | 252 | OK | | |+----+-------------+---------------------+---------------+------------------+---------------+----------+------+--------------+-------+ | || - | 4 | Online,Spun Up | None | 0003 | Z1W1G8X3 | 931.51GB | SAS | 252 | OK | | |+----+-------------+---------------------+---------------+------------------+---------------+----------+------+--------------+-------+ | || - | 5 | Online,Spun Up | None | 0003 | Z1W1G6E7 | 931.51GB | SAS | 252 | OK | | |+----+-------------+---------------------+---------------+------------------+---------------+----------+------+--------------+-------+ | || - | 6 | Online,Spun Up | None | 0003 | Z1W1G6RK | 931.51GB | SAS | 252 | OK | | |+----+-------------+---------------------+---------------+------------------+---------------+----------+------+--------------+-------+ | || - | 7 | Hot Spare,Spun Down | None | 0003 | Z1W1G6SM | 931.51GB | SAS | 252 | OK | | |+----+-------------+---------------------+---------------+------------------+---------------+----------+------+--------------+-------+ | || - | 0 | Online,Spun Up | None | 0003 | Z1W1G6ZW | 931.51GB | SAS | 65535 | OK | | |+----+-------------+---------------------+---------------+------------------+---------------+----------+------+--------------+-------+ | || - | 1 | Online,Spun Up | None | 0003 | Z1W1G6SJ | 931.51GB | SAS | 65535 | OK | | |+----+-------------+---------------------+---------------+------------------+---------------+----------+------+--------------+-------+ | | | +---------------------------------------------------------------------------------------------------------------------------------------+
Example 5 - Use the Monitor > Hardware ShowHealth Appliance Product command to show the appliance serial number:
abc123.Monitor> Hardware ShowHealth Appliance Product Compute Node abc123.veritas.com Time Monitoring Ran: Sun Apr 10 2016 22:25:08 CDT +-----------------------------------------------+ | Hardware monitor information | |+----------------+--------------+------------+ | || Name | Manufacturer | Serial | | |+----------------+--------------+------------+ | || Velocity 7330 | Veritas | VRTS123456 | | |+----------------+--------------+------------+ | | | +-----------------------------------------------+
Example 6 - Use the Monitor > Hardware ShowHealth PrimaryShelf Controller command to show the controller information for the Primary Storage Shelf:
abc123.Monitor> Hardware ShowHealth PrimaryShelf Controller Compute Node abc123.veritas.com Time Monitoring Ran: Sun Apr 10 2016 22:25:08 CDT Compute node does not have any errors. +---------------------------------------------------------------------------+ | Primary Storage Shelf Controller Information | |+-------------------------------------------------------------------------+| ||ID|Location|Data Cache| Controller|NVSRAM Firmware |Status|State|Acknowl-|| || | | | Firmware | | | |edge || ||--+--------+----------+-----------+----------------+------+-----+--------|| ||1 |Tray 99 |8192 MB/ |08.10.03.00|N5501-810898-403|Online|OK |N/A || || |Slot A |10240 MB | | | | | || ||--+--------+----------+-----------+----------------+------+-----+--------|| ||2 |Tray 99 |8192 MB/ |08.10.03.00|N5501-810898-403|Online|OK |N/A || || |Slot B |10240 MB | | | | | || |+-------------------------------------------------------------------------+| +---------------------------------------------------------------------------+
Example 7 - Use the Monitor > Hardware ShowHealth ExpansionShelf Fan command to show the fan information for the Expansion Storage Shelf:
abc123.Monitor> Hardware ShowHealth ExpansionShelf Fan Compute Node abc123.veritas.com Time Monitoring Ran: Sun Apr 10 2016 22:25:08 CDT Compute node does not have any errors. +------------------------------------------------------------+ | Expansion Storage Shelf Fan Information | |+----------------------------------------------------------+| ||ID| Location | Status | State | Acknowledge || ||--+------------+------------+---------+-------------------|| ||1 |Tray 0 Right|Optimal |OK |N/A || ||--+------------+------------+---------+-------------------|| ||2 |Tray 0 Left |Optimal |OK |N/A || ||--+------------+------------+---------+-------------------|| ||3 |Tray 0 Right|Optimal |OK |N/A || ||--+------------+------------+---------+-------------------|| ||4 |Tray 0 Left |Optimal |OK |N/A || |+----------------------------------------------------------+| +------------------------------------------------------------+