Virtual Machine backup job fails with error - 0x200095bf - A failure occured while locking the virtual machine in place for backup/restore operations.

文章: 100050489
上次发布时间: 2021-05-26
评级: 0 0
产品: Backup Exec

Problem

Virtual Machine backup job via Vcenter or ESXi fails with following error.

 

Error Message

0x200095bf - A failure occured while locking the virtual machine in place for backup/restore operations.
VDDK-Warn: VixDiskLibVim: Login failure. Callback error 30201 at 3580. 
V-79-8192-38335 - A failure occured while locking the virtual machine in place for backup/restore operations.

Errors found in SGMon Log :

[fsys\shared]        - VDDK-Log: VixDiskLibVim: Login completed
[fsys\shared]        - VDDK-Log: VixDiskLibVim: Callback for verifying SSL certificate.
[fsys\shared]        - VDDK-Log: VixDiskLibVim: Failed to verify SSL certificate: actual thumbprint=11:E3:AD:3C:E7:1F:5F:7D:DF:D5:30:68:1E:25:B4:80:C6:3A:B5:XX expected=12:CB:85:ED:EC:48:B9:4C:70:94:D4:9A:35:85:6D:D6:F9:4D:94:XX
[fsys\shared]        - VDDK-Log: VixDiskLibVim: SSL certificate verification is done.
[fsys\shared]        - VDDK-Log: VixDiskLibVim: Callback for login.
[fsys\shared]        - VDDK-Log: VixDiskLibVim: Get error from listener.
[fsys\shared]        - VDDK-Log: VixDiskLibVim: Retrieve information from VIM fault.
[fsys\shared]        - VDDK-Log: VixDiskLibVim: VixDiskLibVimGetFaultReason: fault (null) does not have reason.
[fsys\shared]        - VDDK-Log: VixDiskLibVim: basicHttp/libcurl error code is 49, translated to VixError 30201 (30201).
[fsys\shared]        - VDDK-Log: VixDiskLibVim: Error 30201 (listener error GVmomiFaultInvalidResponse).
[fsys\shared]        - VDDK-Warn: VixDiskLibVim: Login failure. Callback error 30201 at 3580.
[fsys\shared]        - VDDK-Log: VixDiskLibVim: Failed to find the VM. Error 30201 at 3735.
[fsys\shared]        - VDDK-Log: VixDiskLibVim: Logout ticket queue.

 

Cause

The issue is seen if SSL certificate of vCenter server is expired or due SHA type mismatch of SSL certificates.

 

Solution

Please note that this article references sites not owned or maintained by Veritas and, as such, Veritas is not responsible for the content portrayed on such sites, including any revisions to or deletions of content or third-party software on which this article relies. User is responsible for conducting all necessary due diligence prior to following the instructions described in this article.

 