Translation Notice
Please note that this content includes text that has been machine-translated from English. Veritas does not guarantee the accuracy regarding the completeness of the translation. You may also refer to the English Version of this knowledge base article for up-to-date information.
vcs-sol10_x64-VRTSvcsag-6.0.3.100
Patch
Obsolete
Abstract
This update was migrated from sort.veritas.com. For details (readme, files, etc.), click the 'Update name' link to view the update download page for this update.
Description
OS update support:
SORT ID: 7575
Fixes the following incidents:
3093828
Patch ID:
149791-01
* * * READ ME * * *
* * * Veritas Cluster Server 6.0.3 * * *
* * * Public Hot Fix 1 * * *
Patch Date: 2013-04-09
This document provides the following information:
* PATCH NAME
* OPERATING SYSTEMS SUPPORTED BY THE PATCH
* PACKAGES AFFECTED BY THE PATCH
* BASE PRODUCT VERSIONS FOR THE PATCH
* SUMMARY OF INCIDENTS FIXED BY THE PATCH
* DETAILS OF INCIDENTS FIXED BY THE PATCH
* INSTALLATION PRE-REQUISITES
* INSTALLING THE PATCH
* REMOVING THE PATCH
PATCH NAME
----------
Veritas Cluster Server 6.0.3 Public Hot Fix 1
OPERATING SYSTEMS SUPPORTED BY THE PATCH
----------------------------------------
Solaris 10 X86
PACKAGES AFFECTED BY THE PATCH
------------------------------
VRTSvcsag
BASE PRODUCT VERSIONS FOR THE PATCH
-----------------------------------
* Veritas Cluster Server 6.0.1
* Veritas Storage Foundation for Oracle RAC 6.0.1
* Veritas Storage Foundation Cluster File System 6.0.1
* Veritas Storage Foundation High Availability 6.0.1
* Symantec VirtualStore 6.0.1
SUMMARY OF INCIDENTS FIXED BY THE PATCH
---------------------------------------
Patch ID: 149791-01
* 3093828 (3125918) AMF driver panics the node when vxconfigd is unresponsive.
DETAILS OF INCIDENTS FIXED BY THE PATCH
---------------------------------------
This patch fixes the following Symantec incidents:
Patch ID: 149791-01
* 3093828 (Tracking ID: 3125918)
SYMPTOM:
AMF driver panics the node when vxconfigd is unresponsive.
DESCRIPTION:
The libusnp_vxnotify.so library, used for disk group notifications, goes into
an infinite loop when vxconfigd daemon is unresponsive. This causes AMF to
enter an inconsistent state; as a result, the AMF driver panics the node.
RESOLUTION:
Symantec has modified the AMF driver and libusnp_vxnotify.so
library to address this issue.
INSTALLING THE PATCH
--------------------
Prerequisites:
* The system must have VRTSvcsag 6.0.300.0 installed before installation of
this patch.
* Install VRTSamf 6.0.300.100 (or later) patch before installing this patch.
The VRTSvcsag-6.0.300.100 patch may be installed either manually (see below)
or using the included installer.
* To apply the patch using the installer, enter the commands
# cd && ./installVCSAG603P1 [ ... ]
where
is the directory where you unpacked this hotfix
, , ...
are the nodes to be patched. If none are specified, you
will be prompted to enter them interactively. All nodes
must belong to a single cluster.
For information about installer options, run './installVCSAG603P1 -help'.
* To apply the patch manually, perform the following steps on all nodes in
the VCS cluster:
1. Stop VCS:
# hastop -local -force
2. Change to the directory where the patch is located and install the patch
using the commands shown below:
# cd /patches && patchadd 149791-01
3. Verify that the new patch is installed by executing the command below
and confirm the output displayed matches the text which follows.
# showrev -p | grep 149791-01
Expected output if patch is installed:
Patch: 149791-01 Obsoletes: Requires: 148493-01 Incompatibles: Packages: VRTSvcsag
4. Restart VCS on one node:
# hastart
After this node goes to LOCAL_BUILD or RUNNING state, execute the
hastart command on all other nodes in the cluster.
REMOVING THE PATCH
------------------
REMOVING THE PATCH
------------------
Run the following steps on all the nodes in the VCS cluster.
1. Stop VCS:
# hastop -local -force
2. Uninstall the patch:
# patchrm 149791-01
3. Verify that the patch is uninstalled from the node:
# showrev -p | grep 149791-01
If the patch was successfully uninstalled, there will be no output.
4. Restart VCS on one node:
# hastart
After this node goes to LOCAL_BUILD or RUNNING state, execute the
hastart command on all other nodes in the cluster.
SPECIAL INSTRUCTIONS
--------------------
Install VRTSamf 6.0.300.100 (or later) patch before installing this patch.
OTHERS
------
NONE
Applies to the following product releases
This update is obsolete and is superseded by
This update was migrated from sort.veritas.com. For details (readme, files, etc.), click the 'Update name' link to view the update download page for this update.
This update requires
This update was migrated from sort.veritas.com. For details (readme, files, etc.), click the 'Update name' link to view the update download page for this update.
Update files
|
File name | Description | Version | Platform | Size |
---|