Please enter search query.
Search <book_title>...
Storage Foundation for Sybase ASE CE 7.4.1 Configuration and Upgrade Guide - Linux
Last Published:
2019-06-18
Product(s):
InfoScale & Storage Foundation (7.4.1)
Platform: Linux
- Section I. Configuring SF Sybase ASE CE
- Preparing to configure SF Sybase CE
- Configuring SF Sybase CE
- Configuring the SF Sybase CE components using the script-based installer
- Configuring the SF Sybase CE cluster
- Configuring SF Sybase CE in secure mode
- Configuring a secure cluster node by node
- Configuring the SF Sybase CE cluster
- Configuring SF Sybase CE clusters for data integrity
- Setting up disk-based I/O fencing using installer
- Performing an automated SF Sybase CE configuration
- Performing an automated I/O fencing configuration using response files
- Configuring a cluster under VCS control using a response file
- Section II. Post-installation and configuration tasks
- Section III. Upgrade of SF Sybase CE
- Planning to upgrade SF Sybase CE
- Performing a full upgrade of SF Sybase CE using the product installer
- Performing an automated full upgrade of SF Sybase CE using response files
- Performing a phased upgrade of SF Sybase CE
- Performing a phased upgrade of SF Sybase CE from version 6.2.1 and later release
- Performing a rolling upgrade of SF Sybase CE
- Performing post-upgrade tasks
- Section IV. Installation and upgrade of Sybase ASE CE
- Installing, configuring, and upgrading Sybase ASE CE
- Preparing to configure the Sybase instances under VCS control
- Installing, configuring, and upgrading Sybase ASE CE
- Section V. Adding and removing nodes
- Adding a node to SF Sybase CE clusters
- Adding the node to a cluster manually
- Setting up the node to run in secure mode
- Adding the new instance to the Sybase ASE CE cluster
- Removing a node from SF Sybase CE clusters
- Adding a node to SF Sybase CE clusters
- Section VI. Configuration of disaster recovery environments
- Section VII. Installation reference
- Appendix A. Installation scripts
- Appendix B. Sample installation and configuration values
- Appendix C. Tunable files for installation
- Appendix D. Configuration files
- Sample main.cf files for Sybase ASE CE configurations
- Appendix E. Configuring the secure shell or the remote shell for communications
- Appendix F. High availability agent information
Verifying that the nodes have access to the same disk
Before you test the disks that you plan to use as shared data storage or as coordinator disks using the vxfentsthdw utility, you must verify that the systems see the same disk.
To verify that the nodes have access to the same disk
- Verify the connection of the shared storage for data to two of the nodes on which you installed Veritas InfoScale Enterprise.
- Ensure that both nodes are connected to the same disk during the testing. Use the vxfenadm command to verify the disk serial number.
# vxfenadm -i diskpath
Refer to the vxfenadm (1M) manual page.
For example, an EMC disk is accessible by the /dev/sdx path on node A and the /dev/sdy path on node B.
From node A, enter:
# vxfenadm -i /dev/sdx
SCSI ID=>Host: 2 Channel: 0 Id: 0 Lun: E
Vendor id : EMC Product id : SYMMETRIX Revision : 5567 Serial Number : 42031000a
The same serial number information should appear when you enter the equivalent command on node B using the /dev/sdy path.
On a disk from another manufacturer, Hitachi Data Systems, the output is different and may resemble:
SCSI ID=>Host: 2 Channel: 0 Id: 0 Lun: E
Vendor id : HITACHI Product id : OPEN-3 Revision : 0117 Serial Number : 0401EB6F0002