Please enter search query.
Search <book_title>...
Cluster Server 7.4.1 Configuration and Upgrade Guide - Linux
Last Published:
2019-06-18
Product(s):
InfoScale & Storage Foundation (7.4.1)
Platform: Linux
- Section I. Configuring Cluster Server using the script-based installer
- I/O fencing requirements
- Preparing to configure VCS clusters for data integrity
- About planning to configure I/O fencing
- Setting up the CP server
- Configuring VCS
- Configuring a secure cluster node by node
- Completing the VCS configuration
- Verifying and updating licenses on the system
- Configuring VCS clusters for data integrity
- Setting up disk-based I/O fencing using installer
- Setting up server-based I/O fencing using installer
- Section II. Automated configuration using response files
- Performing an automated VCS configuration
- Performing an automated I/O fencing configuration using response files
- Section III. Manual configuration
- Manually configuring VCS
- Configuring LLT manually
- Configuring VCS manually
- Configuring VCS in single node mode
- Modifying the VCS configuration
- Manually configuring the clusters for data integrity
- Setting up disk-based I/O fencing manually
- Setting up server-based I/O fencing manually
- Configuring server-based fencing on the VCS cluster manually
- Setting up non-SCSI-3 fencing in virtual environments manually
- Setting up majority-based I/O fencing manually
- Manually configuring VCS
- Section IV. Upgrading VCS
- Planning to upgrade VCS
- Performing a VCS upgrade using the installer
- Tasks to perform after upgrading to 2048 bit key and SHA256 signature certificates
- Performing an online upgrade
- Performing a phased upgrade of VCS
- About phased upgrade
- Performing a phased upgrade using the product installer
- Performing an automated VCS upgrade using response files
- Planning to upgrade VCS
- Section V. Adding and removing cluster nodes
- Adding a node to a single-node cluster
- Adding a node to a single-node cluster
- Adding a node to a multi-node VCS cluster
- Manually adding a node to a cluster
- Setting up the node to run in secure mode
- Configuring I/O fencing on the new node
- Adding a node using response files
- Removing a node from a VCS cluster
- Removing a node from a VCS cluster
- Removing a node from a VCS cluster
- Adding a node to a single-node cluster
- Section VI. Installation reference
- Appendix A. Services and ports
- Appendix B. Configuration files
- Appendix C. Configuring LLT over UDP
- Using the UDP layer for LLT
- Manually configuring LLT over UDP using IPv4
- Manually configuring LLT over UDP using IPv6
- Appendix D. Configuring LLT over TCP
- Manually configuring LLT over TCP using IPv4
- Manually configuring LLT over TCP using IPv6
- Appendix E. Migrating LLT links from IPv4 to IPv6 or dual-stack
- Appendix F. Using LLT over RDMA
- Configuring LLT over RDMA
- Configuring RDMA over an Ethernet network
- Configuring RDMA over an InfiniBand network
- Tuning system performance
- Manually configuring LLT over RDMA
- Troubleshooting LLT over RDMA
- Appendix G. Configuring the secure shell or the remote shell for communications
- Appendix H. Installation script options
- Appendix I. Troubleshooting VCS configuration
- Appendix J. Sample VCS cluster setup diagrams for CP server-based I/O fencing
- Appendix K. Upgrading the Steward process
Verifying Array Support Library (ASL)
Make sure that the Array Support Library (ASL) for the array that you add is installed.
To verify Array Support Library (ASL)
- If the Array Support Library (ASL) for the array that you add is not installed, obtain and install it on each node before proceeding.
The ASL for the supported storage device that you add is available from the disk array vendor or Veritas technical support.
- Verify that the ASL for the disk array is installed on each of the nodes. Run the following command on each node and examine the output to verify the installation of ASL.
The following output is a sample:
# vxddladm listsupport all
LIBNAME VID PID ============================================================= libvxhitachi.so HITACHI DF350, DF400, DF400F, DF500, DF500F libvxxp1281024.so HP All libvxxp12k.so HP All libvxddns2a.so DDN S2A 9550, S2A 9900, S2A 9700 libvxpurple.so SUN T300 libvxxiotechE5k.so XIOTECH ISE1400 libvxcopan.so COPANSYS 8814, 8818 libvxibmds8k.so IBM 2107
- Scan all disk drives and their attributes, update the VxVM device list, and reconfigure DMP with the new devices. Type:
# vxdisk scandisks
See the Veritas Volume Manager documentation for details on how to add and configure disks.